Cristina Caranfil

Dr. Cristina Caranfil

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ADAishwarya Devanand
Aishwarya Devanand
CCCristina Caranfil
Cristina Caranfil
MMMichaela Moore
Michaela Moore
NNNicoletta Nandi
Nicoletta Nandi
FTFoong Way David Tai
Foong Way David Tai
RSReena Sidhu
Reena Sidhu
Background/Objectives: Capsule endoscopy (CE) is a non-invasive tool for evaluating small bowel pathology, but prolonged reading times can lead to reader fatigue. Artificial intelligence-integrated reading software has shown promise to overcome this. This study assesses the diagnostic performance of TOP100 against standard human reading (SR) across different clinical indications. Methods: A retrospective single-centre cohort study was conducted at a tertiary referral centre, including patients who underwent PillCam™SB3 CE between January 2023 to August 2025. Initial reading was performed by expert CE readers (>1000 CE experience) considered as SR. Second blinded reading was performed with TOP100. CE findings from SR were compared with those from TOP100. Results: A total of 1382 CE were identified, of which 1374 had complete examinations and TOP100 data for analysis. The most common indications were inflammatory bowel disease (IBD) (51.5%) and iron-deficiency anaemia (IDA) (25.0%). Diagnostic yield was significantly higher with SR than TOP100 (36.0% vs. 27.5%, p < 0.001). TOP100 demonstrated moderate sensitivity but high specificity; 64.0% and 99.0% for active bleeding, 58.2% and 97.5% for angiodysplasia. In overt bleeding and IDA, sensitivity, and specificity for P2 lesions were 61.0% and 94.3%, respectively. Overall sensitivity and specificity were 55.3% and 95.9% for ulcers, 43.1% and 89.0% for erosions. In IBD, ulcer detection was similar, while TOP100 sensitivity for erosions improved by 9.4%. Conclusions: SR remains the reference standard for reading and reporting capsule endoscopies. However, TOP100 may be a useful adjunct to support interpretation and case prioritisation, especially in high-volume centres.

29 July 2026 in Journal of Ultrasound
Verified
Journal Article
Open access
PDF file
Luisa BertinLuisa Bertin
Luisa Bertin
MZMiriana Zanconato
Miriana Zanconato
CCCamilla Cavagna
Camilla Cavagna
Brigida BarberioBrigida Barberio
Brigida Barberio
CCCristina Caranfil
Cristina Caranfil
FZFabiana Zingone
Fabiana Zingone
Primary intestinal lymphangiectasia (PIL; Waldmann’s disease, ORPHA 90362) is a rare protein-losing enteropathy in which dilated intestinal lacteals leak chyle into the gut lumen. Cross-sectional imaging and lymphoscintigraphy have historically dominated assessment, while transabdominal B-mode intestinal ultrasound (IUS)—a cornerstone modality for inflammatory bowel disease—has remained almost unmapped in PIL. We conducted a PRISMA-ScR scoping review (Open Science Framework preregistration gfbc9) of all primary studies reporting transabdominal B-mode IUS in PIL, searching three bibliographic platforms (PubMed/MEDLINE, Ovid Multifile, Scopus) supplemented by forward and backward citation chasing. Studies using only extra-intestinal ultrasound, endoscopic ultrasound, those describing secondary lymphangiectasia or focal lymphangioma, and those using ultrasound only as procedural guidance for lymphangiography were excluded at full-text stage. Fifteen primary studies, published 1986–2026 across thirteen countries, met eligibility (nine paediatric, six adult). All fifteen reported per-patient B-mode IUS findings extractable for synthesis. A consistent sonographic signature emerged: diffuse, regular, slightly hypoechoic small-bowel-wall thickening with preserved five-layer stratification and prominent valvulae conniventes; dilated fluid-filled loops with reduced peristalsis; oedematous mesentery, variable ascites; and characteristically absent mesenteric lymphadenopathy (with two notable exceptions framed only as a research hypothesis). Diagnostic accuracy as a screening tool has been evaluated only in one study ( n = 20: accuracy 80%, 95% CI 56.3–94.3%). We illustrate this signature in a 42-year-old woman with Hennekam syndrome and report quantitative B-mode IUS values as anecdotal single-observation—single sonographer, single device, single fasted time-point, mid-jejunal segment to motivate, prospective standardisation.