Prashanth Shyam Kumar

Dr. Prashanth Shyam Kumar

Pennsylvania State University, State College, Pennsylvania, USA
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2013 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
PRPratyush Rai
Pratyush Rai
SOSechang Oh
Sechang Oh
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
MRMouli Ramasamy
Mouli Ramasamy
RHRobert E. Harbaugh
Robert E. Harbaugh
VVVijay K. Varadan
Vijay K. Varadan
Neurological disorders, cardiovascular diseases and strokes are leading causes of mortality worldwide. Diagnostics and therapeutics for patients under timely point-of-care can save thousands of lives. However, lack of access to minimally-intrusive monitoring systems makes timely diagnosis difficult and sometimes impossible. Existing ambulatory recording equipment are incapable of performing continuous remote patient monitoring because of the inability of conventional silver-silver-chloride-gel-electrodes to perform long-term monitoring, non-reusability, lack of scalable-standardized wireless communication platforms, and user-friendly design. Recent progress in textile-based nanosensors and mobile platforms has resulted in novel wearable health monitoring systems for neurological and cardiovascular disorders. This review paper discusses nanostructured-textile-based dry electrodes that are better suited for long-term measurement of electrocardiography(ECG), electroencephalography(EEG), electrooculography(EOG), electromyography(EMG) and bioimpedance with very low baseline noise, improved sensitivity and seamless integration into garments of daily use. It presents bioelectromagnetic principles of origination and propagation of bioelectric signals and nanosensor functioning, which provide a unique perspective on development of novel wearable systems that harness their potential. Combined with state-of-the-art embedded wireless network devices to communicate with smartphone, laptop or directly to remote server through mobile network (GSM,4G-LTE,GPRS), they can function as wearable wireless health- diagnostic systems that are more intuitive to use.

19 August 2014 in Electronics
Verified
Journal Article
Open access
PDF file
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
PRPratyush Rai
Pratyush Rai
SOSe Chang Oh
Se Chang Oh
MRMouli Ramasamy
Mouli Ramasamy
RHRobert E. Harbaugh
Robert E. Harbaugh
VVVijay Varadan
Vijay Varadan
Wearable and ultraportable electronics coupled with pervasive computing are poised to revolutionize healthcare services delivery. The potential cost savings in both treatment, as well as preventive care are the focus of several research efforts across the globe. In this review, we describe the motivations behind wearable solutions to real-time cardiovascular monitoring from a perspective of current healthcare services, as well as from a systems design perspective. We identify areas where emerging research is underway, namely: nanotechnology in textile-based wearable monitors and healthcare solutions targeted towards smart devices, like smartphones and tablets.

1 November 2013
Verified
Conference Paper
Closed access
ANA. Nelson
A. Nelson
JSJ. Schmandt
J. Schmandt
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
WWW. Wilkins
W. Wilkins
DLD. Lachut
D. Lachut
VVV. Varadan
V. Varadan
Quadriplegia and paraplegia are disabilities that result from injuries to the spinal cord and neuromuscular disorders such as cerebral palsy. Patients suffering from quadriplegia have varied levels of impaired motor movements, hence, performing quotidian tasks like controlling home appliances is challenging for quadriplegics. The use of hand and eye gestures to perform these tasks is a plausible remedy, but available solutions often assume considerable limb movement, are not fit for long-term use, and may not be applicable to quadriplegics with varied range of motor impairments. To address this problem, we present the design, implementation, and evaluation of a multi-sensor gesture recognition system that uses comfortable and low power wearable sensors. We have designed an EOG-based headband using textile electrodes and a glove that uses flex sensors and an accelerometer to detect eye and hand gestures. The gestures are used to control appliances remotely in a home setting and we show that they have good accuracy, latency, and energy consumption characteristics.

26 April 2012
Verified
Conference Paper
Closed access
PDF file
PRPratyush Rai
Pratyush Rai
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
SOSechang Oh
Sechang Oh
HKHyeokjun Kwon
Hyeokjun Kwon
GMGyanesh N. Mathur
Gyanesh N. Mathur
MAM. P. Agarwal
M. P. Agarwal
Simultaneous monitoring of physiological parameters- multi-lead Electrocardiograph (ECG), Heart rate variability, and blood pressure- is imperative to all forms of medical treatments. Using an array of signal recording devices imply that the patient will have to be confined to a bed. Textiles offer durable platform for embedded sensor and communication systems. The smart healthcare textile, presented here, is a mobile system for remote/wireless data recording and conditioning. The wireless textile system has been designed to monitor a patient in a non-obstructive way. It has a potential for facilitating point of care medicine and streamlining ambulatory medicine. The sensor systems were designed and fabricated with textile based components for easy integration on textile platform. An innovative plethysmographic blood pressure monitoring system was designed and tested as an alternative to inflatable blood pressure sphygmomanometer. Flexible dry electrodes technology was implemented for ECG. The sensor systems were tested and conditioned to daily activities of patients, which is not permissible with halter type systems. The signal quality was assessed for it applicability to medical diagnosis. The results were used to corroborate smart textile sensor system's ability to function as a point of care system that can provide quality healthcare.

29 July 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
PRPratyush Rai
Pratyush Rai
MRMouli Ramasamy
Mouli Ramasamy
VVVenkatesh K. Varadan
Venkatesh K. Varadan
Targeted maintenance of blood pressure for hypertensive patients requires accurate monitoring of blood pressure at home. Use of multiparametric vital signs ECG, heart sounds, and thoracic impedance for blood pressure estimation at home has not been reported previously. In an observational multi-site study, 120 subjects (female (N = 61, 52%)) between 18 and 83 years of age were recruited with the following stratification (Normal (20%), prehypertensive (37%), stage 1(26%), and stage 2 (18%). From these subjects, 1686 measurements of blood pressure from a sphygmomanometer were associated with simultaneously acquired signals from the SimpleSense device. An ensemble of tree-based models was trained with inputs as metrics derived from the multiparametric and patient demographics data. A test Mean Absolute Difference (MAD) of ± 6.38 mm of Hg and ± 5.10 mm of Hg were obtained for systolic and diastolic blood pressures (SBP; DBP), respectively. Comparatively, the MAD for wrist-worn blood pressure cuff OMRON BP6350 (GUDID—10073796266353) was ± 8.92 mm of Hg and ± 6.86 mm of Hg, respectively. Machine learning models trained to use multiparametric data can monitor SBP and DBP without the need for calibration, and with accuracy levels comparable to at-home cuff-based blood pressure monitors.

26 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PKPrashanth Shyam Kumar
Prashanth Shyam Kumar
MRMouli Ramasamy
Mouli Ramasamy
KKKamala Ramya Kallur
Kamala Ramya Kallur
PRPratyush Rai
Pratyush Rai
VVVijay K. Varadan
Vijay K. Varadan
Background and Objective: The prevalence of chronic cardiovascular diseases (CVDs) has risen globally, nearly doubling from 1990 to 2019. ECG is a simple, non-invasive measurement that can help identify CVDs at an early and treatable stage. A multi-lead ECG, up to 15 leads in a wearable form factor, is desirable. We seek to derive multiple ECG leads from a select subset of leads so that the number of electrodes can be reduced in line with a patient-friendly wearable device. We further compare personalized derivations to generalized derivations. Methods: Long-Short Term Memory (LSTM) networks using Lead II, V2, and V6 as input are trained to obtain generalized models using Bayesian Optimization for hyperparameter tuning for all patients and personalized models for each patient by applying transfer learning to the generalized models. We compare quantitatively using error metrics Root Mean Square Error (RMSE), R2, and Pearson correlation (ρ). We compare qualitatively by matching ECG interpretations of board-certified cardiologists. Results: ECG interpretations from personalized models, when corrected for an intra-observer variance, were identical to the original ECGs, whereas generalized models led to errors. Mean performance values for generalized and personalized models were (RMSE-74.31 µV, R2-72.05, ρ-0.88) and (RMSE-26.27 µV, R2-96.38, ρ-0.98), respectively. Conclusions: Diagnostic accuracy based on derived ECG is the most critical validation of ECG derivation methods. Personalized transformation should be sought to derive ECGs. Performing a personalized calibration step to wearable ECG systems and LSTM networks could yield ambulatory 15-lead ECGs with accuracy comparable to clinical ECGs.