The development of sensing coatings, as important sensor elements that integrate functionality, simplicity, chemical stability, and physical stability, has been shown to play a major role in electrochemical sensing system development trends. Simple and versatile assembling procedures and scalability make polyelectrolytes highly convenient for use in electrochemical sensing applications. Polyelectrolytes are mainly used in electrochemical sensor architectures for entrapping (incorporation, immobilization, etc.) various materials into sensing layers. These materials can often increase sensitivity, selectivity, and electronic communications with the electrode substrate, and they can mediate electron transfer between an analyte and transducer. Analytical performance can be significantly improved by the synergistic effect of materials (sensing material, transducer, and mediator) present in these composites. As most reported methods for the preparation of polyelectrolyte-based sensing layers are layer-by-layer and casting/coating methods, this review focuses on the use of the latter methods in the development of electrochemical sensors within the last decade. In contrast to many reviews related to electrochemical sensors that feature polyelectrolytes, this review is focused on architectures of sensing layers and the role of polyelectrolytes in the development of sensing systems. Additionally, the role of polyelectrolytes in the preparation and modification of various nanoparticles, nanoprobes, reporter probes, nanobeads, etc. that are used in electrochemical sensing systems is also reviewed.
13 November 2020 in Journal of Solid State Electrochemistry
Carbon nanotubes (CNTs) are widely used in electrochemical sensors due to their significant impact on the electroanalytical signal. However, there remain significant doubts regarding the origin of the improved electroanalytical response observed in CNT-based sensors, particularly concerning the precise role of CNTs in these systems. In particular, the origin of the electrochemical response is controversial, as it may be due to either electrocatalytic or non-electrocatalytic processes. The latter implies that the electroanalytical response is mainly governed by the mass transport phenomena within the porous CNT layer. This article briefly reviews the several comprehensive models based on the role of porosity (diffusion in a ‘thin-layer’) on the electrochemical behavior as well as on the electrocatalytic properties of CNTs to resolve conflicts arising from misinterpretations of the electroanalytical response of CNT-based sensors. However, even though there are some explanations and conclusions on this topic, they seem to be valuable for specific electroactive species, the type of CNTs and/or electrode architecture, the electrode surface, etc. Accordingly, general theories and conclusions are not yet defined, so different approaches to this topic are still needed, since the main phenomenological effects responsible for the nature of the electrochemical response of the electrodes modified with CNTs need to be determined in a rational way.
12 May 2016 in Journal of Solid State Electrochemistry
In this paper, the electrochemical behavior of cysteine is described, using carbon paste electrodes (CPEs) modified with ternary silver-copper sulfide containing intrinsic silver at two pH values (pH 3 and 5). Experiments have revealed that presence of cysteine has a large impact on the electrochemical behavior of modified CPEs. Observed phenomena take place in solution, as well as at the surface of the modified CPEs, and can be applied for electroanalytical purposes. Based on the electrochemical behavior observed in the examined system, differential pulse voltammetry (DPV) was selected as an electroanalytical method for determination of cysteine. The effects of the various parameters on the electroanalytical signal, such as the amount of electroactive material, electroanalytical parameters, pH etc., were investigated using differential pulse voltammograms. The results indicated that electrochemical signal characterized with well-defined cathodic peak at 0.055 V vs. Ag/AgCl (3 M) in acetic buffer solution at pH 5 can be used for indirect electrochemical determination of cysteine. The optimization procedure revealed that the most sensitive and stabile electrode was that containing 5% modifier. The DPV response of the electrode, in the presence of cysteine, showed two different linear concentration ranges of 0.1 to 2.5 μM, and 5.6 to 28 μM. The explanation of the origin of two linear ranges is proposed. The lower concentration range was characterized by remarkable sensitivity of the 11.78 μA μM−1, owing to the chosen indirect method of determination. The calculated limit of detection (LOD), as well as limit of quantification (LOQ) were 0.032 and 0.081 μM, respectively. The influence of interfering agents on the electroanalytical response was examined, and low or no interference on the DPVs was observed. The proposed method was validated and applied for the determination of cysteine in pharmaceutical preparations with satisfactory recoveries in the range of 97 to 101.7%.
3 November 2015 in Monatshefte für Chemie - Chemical Monthly