Gerhard Fischerauer

Dr. Gerhard Fischerauer

Universität Bayreuth, Chair of Measurement and Control Systems, Bayreuth, Germany
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
PDF file
PDPer Delsing
Per Delsing
ACAndrew N Cleland
Andrew N Cleland
MSMartin J A Schuetz
Martin J A Schuetz
JKJohannes Knörzer
Johannes Knörzer
GGGéza Giedke
Géza Giedke
CWChristoph Westerhausen
Christoph Westerhausen
Today, surface acoustic waves (SAWs) and bulk acoustic waves are already two of the very few phononic technologies of industrial relevance and can been found in a myriad of devices employing these nanoscale earthquakes on a chip. Acoustic radio frequency filters, for instance, are integral parts of wireless devices. SAWs in particular find applications in life sciences and microfluidics for sensing and mixing of tiny amounts of liquids. In addition to this continuously growing number of applications, SAWs are ideally suited to probe and control elementary excitations in condensed matter at the limit of single quantum excitations. Even collective excitations, classical or quantum are nowadays coherently interfaced by SAWs. This wide, highly diverse, interdisciplinary and continuously expanding spectrum literally unites advanced sensing and manipulation applications. Remarkably, SAW technology is inherently multiscale and spans from single atomic or nanoscopic units up even to the millimeter scale. The aim of this Roadmap is to present a snapshot of the present state of surface acoustic wave science and technology in 2019 and provide an opinion on the challenges and opportunities that the future holds from a group of renown experts, covering the interdisciplinary key areas, ranging from fundamental quantum effects to practical applications of acoustic devices in life science.

18 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VMValentin Meiler
Valentin Meiler
JPJens Pfeiffer
Jens Pfeiffer
LBLuca Bifano
Luca Bifano
GFGerhard Fischerauer
Gerhard Fischerauer
GFGerhard Fischerauer
Gerhard Fischerauer
We propose electrical impedance spectroscopy enhanced by machine learning, in particular support vector machines, as a non-invasive, in-situ method for detecting microplastics in water and as an alternative to slow, expensive laboratory measurements. The primary measurand is the complex-valued electrical impedance of a water-filled measuring cell. We carried out stationary measurements on numerous water samples contaminated with different plastic concentrations in a cylindrical measuring cell and in the frequency range from 20 Hz to 2 MHz. The effects of various influence quantities, such as the concentration of organic material (1.0 %, 3.0 %, 5.0 %) or the salinity of water (0.5 %, 1.0 %, 3.5 %), were also investigated. Measurements at 2 MHz with water flows carrying microplastic particles of different materials and sizes served to investigate the dynamic capabilities of the measurement method. The impedance spectra (stationary measurements) or the measured impedances (dynamic measurements) were then evaluated by specific SVMs. The classification task consisted of distinguishing different plastic materials and particle sizes. In the stationary case, the application of the SVM resulted in assignment accuracies of over 98 %. In the dynamic case, the classification accuracies exceeded 91 % for the mere classification of particle sizes and 85 % for the classification of plastic particles by size and material.

25 August 2011 in Sensors
Verified
Journal Article
Open access
PDF file
PFPeter Fremerey
Peter Fremerey
SRSebastian Reiß
Sebastian Reiß
AGAndrea Geupel
Andrea Geupel
GFGerhard Fischerauer
Gerhard Fischerauer
Ralf MoosRalf Moos
Ralf Moos
Recently, it has been shown that the degree of loading of several types of automotive exhaust aftertreatment devices can be directly monitored in situ and in a contactless way by a microwave-based method. The goal of this study was to clarify whether this method can also be applied to NOx storage and reduction catalysts (lean NOx traps) in order to obtain further knowledge about the reactions occurring in the catalyst and to compare the results with those obtained by wirebound NOx loading sensors. It is shown that both methods are able to detect the different catalyst loading states. However, the sensitivity of the microwave-based method turned out to be small compared to that previously observed for other exhaust aftertreatment devices. This may limit the practical applicability of the microwave-based NOx loading detection in lean NOx traps.

3 December 2009 in Sensors
Verified
Journal Article
Open access
PDF file
PLPeter Lieberzeit
Peter Lieberzeit
CPChristian Palfinger
Christian Palfinger
Franz DickertFranz Dickert
Franz Dickert
GFGerhard Fischerauer
Gerhard Fischerauer
One-port surface acoustic wave (SAW) devices with defined reflector patterns give characteristic signal patterns in the time domain making them identifiable and leading to so-called RFID-Tags. Each sensor responds with a burst of signals, their timed positions giving the identification code, while the amplitudes can be related to the analyte concentration. This paper presents the first combination of such a transducer with chemically sensitive layer materials. These include crosslinked polyvinyl alcohol for determining relative humidity and tert-butylcalix[4]arene for detecting solvent vapors coated on the free space between the reflectors. In going from the time domain to the frequency domain by Fourier transformation, changes in frequency and phase lead to sensor responses. Hence, it is possible to measure the concentration of tetrachloroethene in air down to 50 ppm, as well as 1% changes in relative humidity.

23 September 2010 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SRSebastian Reib
Sebastian Reib
MSMatthias Sporl
Matthias Sporl
GHGunter Hagen
Gunter Hagen
GFGerhard Fischerauer
Gerhard Fischerauer
Ralf MoosRalf Moos
Ralf Moos
Recently, a novel approach for the characterization of the state of automotive catalysts has been proposed, viz., the direct electrical characterization of the catalyst material itself. This direct approach has the potential to do away with the complex models needed by indirect measurement methods to infer the catalyst state, for instance from the oxygen partial pressure outside of the catalyst determined by lambda probes. In this work, we compare two ways of directly observing the catalyst state. Firstly, the electrical conductivity of the catalyst material is determined by wirebound sensors mounted inside of the catalyst and fabricated from catalyst-formulation coated planar interdigital electrodes. Secondly, we employ a contactless method based on the perturbation of the partially filled microwave cavity resonator formed by the catalyst and its metallic housing. For a better understanding of the observed effects, the data obtained at microwave frequencies from engine tests are compared with the local electrical conductivity measurements. It is shown that both methods give a coherent picture of the oxygen loading state of an automotive three-way catalyst and that both methods enable one to follow the progress of reaction fronts inside the catalyst. Furthermore, it is demonstrated that the resonance frequency is strongly correlated with the oxygen load.

28 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
MMMario Mösch
Mario Mösch
GFGerhard Fischerauer
Gerhard Fischerauer
Vibration energy harvesters transform environmental vibration energy into usable electrical energy. The transformation is only possible because of a coupling between the mechanical part of the energy harvester and the electric circuit. This paper compares several measurement methods to determine the electromagnetic coupling coefficient. These methods are applied to various implementations of an energy harvester and the results are compared with one another and with simulation data by analyzing the magnetic flux. The average deviation between the measurement methods and the simulation data in our study was 5%. This good agreement validates the methods. Based on this, we recommend determination of the coupling coefficient and the optimum load resistance for maximum power harvesting on the basis of simulations and the open circuit method, because this procedure leads to the shortest measurement times.