Zhilu Ye

Zhilu Ye


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MYMinye Yang
Minye Yang
ZYZhilu Ye
Zhilu Ye
YRYichong Ren
Yichong Ren
MFMohamed Farhat
Mohamed Farhat
Pai-Yen ChenPai-Yen Chen
Pai-Yen Chen
The intersection of biomedicine and radio frequency (RF) engineering has fundamentally transformed self-health monitoring by leveraging soft and wearable electronic devices. This paradigm shift presents a critical challenge, requiring these devices and systems to possess exceptional flexibility, biocompatibility, and functionality. To meet these requirements, traditional electronic systems, such as sensors and antennas made from rigid and bulky materials, must be adapted through material science and schematic design. Notably, in recent years, extensive research efforts have focused on this field, and this review article will concentrate on recent advancements. We will explore the traditional/emerging materials for highly flexible and electrically efficient wearable electronics, followed by systematic designs for improved functionality and performance. Additionally, we will briefly overview several remarkable applications of wearable electronics in biomedical sensing. Finally, we provide an outlook on potential future directions in this developing area.

17 February 2025 in Discover Electronics
Verified
Journal Article
Open access
PDF file
YZYue Zhang
Yue Zhang
YWYijing Wang
Yijing Wang
KZKun Zhao
Kun Zhao
MYMinye Yang
Minye Yang
ZYZhilu Ye
Zhilu Ye
XZXiaohui Zhang
Xiaohui Zhang
Wireless electrical stimulation devices have gained considerable attention due to their potential to offer therapeutic benefits in various medical applications, including pain management, neurological rehabilitation, and tissue regeneration. Traditionally, electrical stimulation is delivered through large, hospital-based equipment, limiting patient accessibility and convenience. Recent advancements in wearable and implantable devices, however, have paved the way for in-home electrical stimulation therapies. These devices, designed to be wireless and battery-free, offer greater flexibility, but their development hinges on effective methods of wireless power transfer. This review explores key approaches for wirelessly powering these devices, such as inductive coupling, mechanical energy harvesting, magnetic field induction, and optical power transfer. Each method presents unique advantages and limitations in terms of efficiency, range, and practicality for wearable or implantable use. Additionally, we discuss emerging materials that enhance device performance, including bioabsorbable materials that degrade naturally after use, stretchable materials that improve stretchability, and self-adhesive materials that enhance secure attachment. This review provides a comprehensive overview of the key strategies and materials that are driving the development of more effective and accessible electrical stimulation technologies. These advancements hold great promise for improving patient outcomes and expanding the use of electrical stimulation in both clinical and at-home therapies.

18 October 2024 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
CZCuiling Zhang
Cuiling Zhang
QZQi Zhang
Qi Zhang
XLXinran Li
Xinran Li
WZWang Zhan
Wang Zhan
YHYongliang Han
Yongliang Han
XZXiaohui Zhang
Xiaohui Zhang
Magnetoresistive (MR) sensors with the ability to detect external magnetic fields have attracted increasing attention in interactive human–machine interfaces and biomedical devices. However, existing MR sensors are typically constructed from rigid and bulky materials, failing to satisfy the flexibility and biocompatibility requirements for on-skin electronics. In this study, a flexible and biocompatible anisotropic magnetoresistance (AMR) film with a cross-linked silk substrate and a NiCo functional layer is reported for on-skin monitoring applications. The synergy of hydrogen bonds and the cross-linking network enhances the flexibility and mechanical stability of the silk film by forming an amorphous entanglement network with a reduced presence of large and compact β-sheet crystals. The developed AMR film exhibits a high AMR ratio of 1.03%, comparable to those obtained with rigid AMR sensors. Under external magnetic fields, the silk-based AMR film demonstrates the ability to monitor its rotation (0–90°), bending (radius 10–60 mm), and distance (0–10 cm) to the magnet. Furthermore, we practically implement the flexible AMR film for skin-interfaced applications, including the detection of joint motions (e.g. wrist, ankle, and finger movements) and the control of turning pages. The proposed flexible magnetic film paves the way for the development of magnetosensitive electronic skins and wearable sensors.

25 May 2026 in Advanced Science
Verified
Journal Article
Open access
PDF file
YWYijing Wang
Yijing Wang
JTJingyu Tian
Jingyu Tian
ZXZhe Xu
Zhe Xu
CZCuiling Zhang
Cuiling Zhang
JWJingen Wu
Jingen Wu
XZXiaohui Zhang
Xiaohui Zhang
Electrical stimulation is widely recognized as an effective strategy for promoting functional recovery after peripheral nerve injury. However, conventional stimulators rely on wired connections or implanted batteries, severely limiting implantability, biosafety, and clinical translation. Recent wireless, battery‐free piezoelectric systems, primarily based on ultrasound or pressure‐driven transduction, remain constrained by auxiliary equipment, working distance, and external control. Here, we report a fully wireless, circuit‐free neural stimulator built on a millimetric magneto‐mechano‐electric (MME) cantilever transducer (3 × 10 × 5 mm) with a barium titanate (BTO) piezoelectric ceramic core. Under low‐frequency alternating magnetic fields, the MME cantilever mechanically oscillates, inducing stress on the BTO element and thereby converting magnetic energy into therapeutic electrical pulses. The use of BTO minimizes potential biosafety risks. Moreover, the device operates stably at 16 cm from the magnetic source, outperforming most existing wireless stimulators. In vitro, MME‐mediated stimulation doubles PC12 neurite outgrowth and neuronal differentiation. In a rat sciatic nerve injury model, the implanted stimulator exhibits excellent biosafety and significantly enhances nerve regeneration and motor recovery, achieving a ∼1.5‐fold improvement in the sciatic functional index.