Zhengyao He

Prof. Zhengyao He


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
ZHZhengyao He
Zhengyao He
FZFan Zheng
Fan Zheng
YMYuanliang Ma
Yuanliang Ma
Hyung Ham KimHyung Ham Kim
Hyung Ham Kim
QZQifa Zhou
Qifa Zhou
KSK. Kirk Shung
K. Kirk Shung
A method is proposed to suppress sidelobe level for near-field beamforming in ultrasound array imaging. An optimization problem is established, and the second-order cone algorithm is used to solve the problem to obtain the weight vector based on the near-field response vector of a transducer array. The weight vector calculation results show that the proposed method can be used to suppress the sidelobe level of the near-field beam pattern of a transducer array. Ultrasound images following the application of weight vector to the array of a wire phantom are obtained by simulation with the Field II program, and the images of a wire phantom and anechoic sphere phantom are obtained experimentally with a 64-element 26 MHz linear phased array. The experimental and simulation results agree well and show that the proposed method can achieve a much lower sidelobe level than the conventional delay and sum beamforming method. The wire phantom image is demonstrated to focus much better and the contrast of the anechoic sphere phantom image improved by applying the proposed beamforming method.

15 July 2014 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
YWYong Wang
Yong Wang
YYYixin Yang
Yixin Yang
YMYuanliang Ma
Yuanliang Ma
ZHZhengyao He
Zhengyao He
YLYuKang Liu
YuKang Liu
The solutions of pattern synthesis are derived for circular sensor arrays based on the criterion of minimizing the mean square error between the desired and synthesized beampatterns. Specifically, the optimal weighting vector, the output beam, and the minimum mean square error are all expressed in closed-form exactly when the desired beampattern is properly formulated. These results provide a more effective and convenient scheme for designing practical frequency-invariant beamformers. Simulations and experimental results demonstrate the performance of the proposed approach.

1 May 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
ZHZhengyao He
Zhengyao He
YMYuanliang Ma
Yuanliang Ma
A method is presented to calculate the driving-voltage weighting vector of a conformal array of underwater acoustic transmitting transducers to obtain a low-sidelobe beam pattern based on the measured receiving array manifold. The relationship among three quantities is given, which are, respectively, the radiated acoustic field, the measured receiving array manifold matrix and the driving-voltage weighting vector of the transducer array. Then, the driving-voltage weighting vector of the array is calculated using the optimization method to obtain a low-sidelobe transmitting beam pattern. At the frequency of 12.5kHz, the receiving array manifold matrix of a 27-element conformal array is measured in an anechoic water tank. The driving-voltage weighting vector of the array is calculated using the proposed method. In addition, the computer simulation and experiments are carried out. The results agree well and show that the proposed method can obtain a low-sidelobe transmitting beam pattern and at the same time provide the largest amplitude of pressure in the axial direction when the maximum amplitude of the driving voltages of the array elements keeps unchanged.

1 January 2014 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
PDF file
ZHZhengyao He
Zhengyao He
A method is proposed to calculate the weight vector of a transducer array for ultrasound imaging to obtain a low-sidelobe transmitting beam pattern based on the near-field response vector. An optimization problem is established, and the second-order cone (SOC) algorithm is used to solve the problem to obtain the weight vector. The optimized acoustic emitted field of the transducer array is then calculated using the Field II program by applying the obtained weight vector to the array. The simulation results with a 64-element 26 MHz linear phased array show that the proposed method can be used to control the sidelobe of the near-field transmitting beam pattern of the transducer array and achieve a low-sidelobe level. The near-field sound pressure distribution of the transducer array using the proposed method focuses much better than that using the standard delay and sum (DAS) beamforming method. The sound energy is more concentrated using the proposed method.


1 August 2011 in Chinese Physics B
Verified
Journal Article
Closed access
PDF file
ZHZhengyao He
Zhengyao He
YMYuan-Liang Ma
Yuan-Liang Ma
The acoustic radiation characteristics of free-flooded ring transducers made of PZT4 and PMN—PT materials are calculated and compared. First, the theoretical formulae for free-flooded ring transducers are studied. The resonant frequencies of a transducer made of PZT4 and PMN—PT materials are calculated. Then, the transmitting voltage responses of the free-flooded ring transducers are calculated using the finite element method. Finally, the acoustic radiation characteristics of the free-flooded ring transducers are calculated using the boundary element method. The calculated results show that the resonant frequencies of the free-flooded ring transducer made of PMN—PT are greatly reduced compared with those made of PZT4 with the same size. The transmitting voltage response of the transducer made of PMN—PT is much higher than that of the transducer made of PZT4. The calculated 3-dB beamwidth of the acoustic radiated far-field directivity of the free-flooded ring transducer made of PZT4 at the resonant frequency 1900 Hz is 63.6° and that of the transducer made of PMN—PT at the resonant frequency 1000 Hz is 64.6°. The comparison results show that the free-flooded ring transducer made of PMN—PT material has many advantages over that made of PZT4. The PMN—PT is a promising material for improving the performance of free-flooded ring transducers.