Reinier Hoogeveen

Dr. Reinier Hoogeveen

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
GSGch Sanderink
Gch Sanderink
WBWer Berkhout
Wer Berkhout
During a cone beam CT scan, the patient is in an upright or supine position. This position depends on the brand and type of the scanner. The aims of this study are: (1) to investigate if the head position has an effect on cephalometric evaluation of the soft-tissue facial profile, comparing the recordings in natural head position (NHP) and supine head position (SHP) and (2) to investigate if age, gender and body mass index (BMI) are contributing factors to the effect of the head position. 90 subjects were photographed in profile both in NHP and in SHP. 12 soft-tissue angular and linear cephalometric values were calculated. Two-way random intraclass correlation coefficients were calculated to determine observer reliability. Paired t-tests and linear regression analyses were performed to investigate the differences between the head positions and the influence of age, gender and BMI. Intraobserver reliability was generally high. Paired t-tests showed significant changes as a result of head positioning (p < 0.0001) in 9 of the 12 measurements. These differences were small and clinically not relevant, except for the "lower face-throat angle". Regression analysis revealed no relevant influence of age, gender and BMI. Cephalometric soft-tissue evaluation from a recording in SHP is generally reliable, except for the throat-chin area where a clinically relevant difference was found. The contour of the submandibular tissues in SHP causes the chin to appear more prominently. This can cause incorrect orthodontic diagnosis and treatment planning.

1 May 2016 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
BHBart Hazenoot
Bart Hazenoot
GSGerard. C. H. Sanderink
Gerard. C. H. Sanderink
EBErwin Berkhout
Erwin Berkhout
Aim of the study:To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation.Methods:Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® male phantom with a dosimeter. Four protocols were tested: round collimation (round coll.) and rectangular collimation (rect. coll.), both with and without thyroid shield. Five exposure positions were deployed: upper incisor (Isup), upper canine (Csup), upper premolar (Psup), upper molar (Msup) and posterior bitewing (BW). Exposures were made with 70kV, 7 mA and were repeated ten times. The exposure times were as recommended for the exposure positions for the respective collimator type by the manufacturer for digital imaging. The data were statistically analysed with a three way ANOVA test. Significance was set at p< 0.01.Results:The ANOVA test revealed that the differences between mean doses of all protocols and geometries were statistically signifi...

1 April 2015 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
DRD Rottke
D Rottke
PSP F van der Stelt
P F van der Stelt
WBW E R Berkhout
W E R Berkhout
Objectives: To test the dose-reducing capabilities of a novel thyroid protection device and a recently introduced cranial collimator to be used in orthodontic lateral cephalography. Methods: Cephalographic thyroid protector (CTP) was designed to shield the thyroid while leaving the cervical vertebrae depicted. Using a RANDO (R) head phantom (The Phantom Laboratory, Salem, NY) equipped with dosemeters and a Proline XC (Planmeca, Helsinki, Finland) cephalograph, lateral cephalograms were taken, and the effective dose (ED) was calculated for four protocols: (1) without shielding; (2) with CTP; (3) with CTP and anatomical cranial collimator (ACC); and (4) with a thyroid collar (TC). Results: The ED for the respective protocols was (1) 8.51; (2) 5.39; (3) 3.50; and (4) 4.97 mu Sv. The organ dose for the thyroid was reduced from 30.17 to 4.50 mu Sv in Protocols 2 and 3 and to 3.33 mu Sv in Protocol 4. Conclusions: The use of just the CTP (Protocol 2) resulted in a 36.8% reduction of the ED of a lateral cephalogram. This was comparable to the classical TC (Protocol 4). A 58.8% reduction of the ED was obtained when combining CTP and ACC (Protocol 3). The dose to the radiosensitive thyroid gland was reduced by 85% in Protocols 2 and 3 and by 89% in Protocol 4.

18 November 2019 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
MHMarinka L.F. Hol
Marinka L.F. Hol
BPBradley Rumwell Pieters
Bradley Rumwell Pieters
BBBrian V. Balgobind
Brian V. Balgobind
EBErwin Berkhout
Erwin Berkhout
EBEddy A.G. Becking
Eddy A.G. Becking
Objectives: In paediatric cancer survivors treated with chemotherapy and radiotherapy therapy, late effects on dental development are quite common. Oral radiologists are not familiar with the radiographic images of these specific dental consequences of chemotherapy and radiotherapy. With the goal of educating colleagues, to raise awareness of the needs of survivors, and to identify directions for future research, we present dental radiographs of survivors treated for head and neck rhabdomyosarcoma with chemotherapy and radiotherapy. Also, based on the survivors reviewed, a radiographic inventory of commonly found late dental developmental effects seen in conjunction with treatment is presented.Methods: Panoramic radiographic findings of five illustrative cases are presented, from a group of 42 survivors of head and neck rhabdomyosarcoma treated at the Academic Medical Center Amsterdam, The Netherlands over the past 25 years.Results: Five cases showing dental developmental disorders are presented. These cases show an association of the location of the radiation field and the developmental stage of the teeth with the severity of the effect on dental development. We also report an inventory of severe and moderate effects of chemotherapy and radiotherapy on the development of molars and anterior teeth.Conclusions: This paper presents five cases and a radiographic inventory to illustrate disturbances of dental development associated with chemotherapy and radiotherapy in children. Medical and dental professionals involved in the treatment of cancer survivors are relatively unaware of the dental consequences of radiation therapy and the age dependency of specific regional effects. These effects can be severe, with great impact on quality of life. Further research in this area could help improve planning of radiation therapy for children, potentially preventing or limiting dental or maxillofacial sequelae.

1 July 2019 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
BMBram R. Meertens
Bram R. Meertens
EBErwin Berkhout
Erwin Berkhout
Background: Hand-held (HH) X-ray devices are currently introduced for routine dentistry in some global areas. Safety issues are resolved but imaging quality aspects remain to be explored. Aim: To compare the aiming accuracy of two intraoral radiography devices: the portable Nomad Pro2 and the wall-mounted (WM) Planmeca Intra. Setting and design: In vitro experimentation involving radiologic mannequins and unbiased student operators. Methods and materials: 20 operators obtained intraoral radiographs of four regions (bitewing, upper molar, lower molar and upper anterior) in five mannequins, using HH and WM devices. Beam-aiming devices were fitted with metal cross-wires to project on image sensors. Deviation from ideal perpendicular incidence of beam was calculated, based on positions of cross-wires relative to gold-standard positions (i.e. average of 10-fold precise aiming by authors via WM system). Analytic models relied on Wilcoxon signed-rank test and mixed model analyses. Results: Mean deviations from perfect aim were 2.88˚ (± 1.80˚) for WM and 3.06˚ (± 1.90˚) for HH methods. The difference among all operators (HH vs WM) was 0.17˚ (± 2.48˚), which was not significant. Seven operators showed better aim by HH device (13 by WM system); and in one instance, this difference was significant. Conclusions: Aiming precision proved similar for HH and WM methods of intraoral radiography, although individual operators may perform better using one of these modalities. Aim is not an expected limiting factor for image quality in HH (vs WM) diagnostics.

1 July 2021 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
RHReinier Hoogeveen
Reinier Hoogeveen
SOSiham Ouchene
Siham Ouchene
EBErwin Berkhout
Erwin Berkhout
Objectives: The present clinical trial was intended to clarify whether subjective assessments of diagnostic X-ray image quality achieved via hand-held (HH) Nomad Pro 2 (KaVo Kerr, Brea, CA, USA) X-ray device is non-inferior that of the wall-mounted (WM) KaVo Focus (KaVo Dental, Bieberich, Germany). Methods: A prospective, cross-over, and in vivo non-inferiority clinical trial was conducted to compare these two diagnostic modalities. Based on sampling calculations, 205 patients were selected for study, generating 410 paired bitewing radiographs in randomized sequence. The films were assessed independently, engaging three observers blinded to modality for random, side-by-side-comparisons. Diagnostic image quality was rated as follows: no preference, HH preference, or WM preference. Observer judgements were combined accordingly to reach a majority. Results: Collective observer ratings indicated no preference for diagnostic image quality in 63.9% of cases, with WM preference at 16.6% and HH preference at 19.5%. The difference in HH and WM preferences (19.5%–16.6% = 2.9%) was within the expected 95% confidence interval. Majority agreement was reached in 82.7%. Conclusions: Subjectively assessed diagnostic image quality in bitewing radiographs acquired by HH and WM devices did not differ significantly. The hand-held device is thus non-inferior to the WM in this regard. Our data set of paired bitewing radiographs may subsequently aid in future research.