Lawrance K Chung

Dr. Lawrance K Chung

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of the Neurological Sciences
Verified
Journal Article
Closed access
MUMethma Udawatta
Methma Udawatta
KPKomal Preet
Komal Preet
CLCarlito Lagman
Carlito Lagman
AFAlexis M. French
Alexis M. French
CBColleen Bruton
Colleen Bruton
IYIsaac Yang
Isaac Yang

26 April 2024 in World Neurosurgery
Verified
Journal Article
Closed access
SSShane Shahrestani
Shane Shahrestani
LCLawrance K Chung
Lawrance K Chung
NBNolan J Brown
Nolan J Brown
SRSofia Reese
Sofia Reese
RLRyan C. Liu
Ryan C. Liu
MSMichael M. Safaee
Michael M. Safaee

31 January 2026 in Neurospine
Verified
Journal Article
Open access
NWNoah Willett
Noah Willett
CIChibuikem Anthony Ikwuegbuenyi
Chibuikem Anthony Ikwuegbuenyi
EWEvan Wang
Evan Wang
LCLawrance K Chung
Lawrance K Chung
ARAnthony Robayo
Anthony Robayo
ADAo Spine Knowledge Forum Degenerative
Ao Spine Knowledge Forum Degenerative
To address disc reherniation, several annular repair strategies have been developed, including implantable devices, suture-based techniques, and biomaterials. This review evaluates the clinical evidence supporting these strategies. A systematic search of PubMed, Cochrane, and Embase and MEDLINE via Ovid was performed from database inception to July 2025. A combination of keywords was used in the search string. Publications were included if they were clinical studies and described closing the annulus or blocking the annulus defect with biologics, sutures, or physical devices. Exclusion criteria were animal studies, in vitro studies, non-English articles, and abstracts. A single-arm proportional meta-analysis was performed for studies reporting extractable reherniation, reoperation, or complication data. The initial search identified 1,349 records. After removal of 315 duplicates, 1,034 studies underwent screening, with 84 full texts reviewed and 62 meeting inclusion criteria. Forty-one studies (66%) assessed implantable physical devices, of which 40 (98%) evaluated the Barricaid annular closure device (ACD) (Intrinsic Therapeutics, Inc., USA). Eighteen studies (29%) evaluated suture-based closure of the annulus fibrosus, using preloaded devices, bone-anchored systems, or manual suturing techniques. Three studies (5%) examined the use of biomaterials as either an adjunct or standalone method in the form of autologous conditioned plasma, bone marrow stromal cells, and fibrin sealant. For physical devices, the pooled reherniation, reoperation, and complication rates were 4.71%, 4.84%, and 1.76% respectively. Suture-based techniques had reherniation, reoperation, and complication rates of 1.37%, 0.35%, and 0.28%, respectively. For biomaterial-based approaches, only a pooled reherniation rate was calculated (2.11%), as insufficient data were available to pool reoperation and complication rates. Annular repair following discectomy is associated with low rates of reherniation, reoperation, and complications across physical devices, suture-based techniques, and biomaterial approaches. Physical devices and suturing techniques have robust clinical evidence and show generally favorable outcomes, but results remain mixed and heterogenous across techniques. Biomaterials demonstrate early promise but are limited by small study size and short follow-up. While pooled proportional meta-analysis supports the overall safety and effectiveness of annular repair, heterogeneity and limited comparative evidence prevent determination of relative superiority.

Verified
Journal Article
Open access
PDF file
AKAhmet Kartal
Ahmet Kartal
GSGayle Salama
Gayle Salama
LCLawrance K Chung
Lawrance K Chung
NMNoel Francis Manalil
Noel Francis Manalil
GEGalal Elsayed
Galal Elsayed
RHRoger Härtl
Roger Härtl
Background: Cage subsidence after minimally invasive transforaminal lumbar interbody fusion raises revision risk and costs. Intraoperative computed tomography (CT) provides high-resolution, three-dimensional visualization of the endplate–cage interface and serves as a practical—though itself imperfect—reference standard for early subsidence, but it is not available at all institutions. Plain X-ray is widely available and inexpensive, but lower in resolution. The clinically relevant question is therefore not whether CT and X-ray are equivalent, but rather which X-ray protrusion depth measurement most reliably identifies CT-confirmed subsidence, and whether a positive intraoperative CT meaningfully predicts later radiographic subsidence. Objective: Using intraoperative CT as reference, we aimed to (1) determine the optimal X-ray protrusion depth threshold for CT-confirmed early subsidence; (2) test whether intraoperative CT predicts late radiographic subsidence; and (3) examine how early X-ray depth relates to intervertebral disc height (IVDH) and segmental lordosis (SL) loss. Methods: In a retrospective single-surgeon cohort (March 2015–July 2023), subsidence was defined as ≥2.0 mm endplate penetration on CT and measured on X-ray by parallax technique. Sensitivity, specificity, accuracy, and Cohen’s κ were calculated. Receiver operating characteristic (ROC) analysis evaluated X-ray depth as a continuous predictor and identified the Youden-optimal cutoff. Intraoperative CT was tested against late radiographic subsidence; no-intercept linear models estimated per-millimeter IVDH and SL loss. Results: Of 100 patients, 93 had paired imaging (mean age 66.7 years; body mass index 26.8 kg/m2). Subsidence appeared on CT in 16.1% and on X-ray in 15.1%. X-ray showed 80.0% sensitivity, 97.4% specificity, 94.6% accuracy, and κ = 0.80; ROC analysis demonstrated strong discrimination (area under the curve 0.91; 95% confidence interval 0.81–1.00), Youden-optimal cutoff 1.90 mm. Intraoperative CT predicted late subsidence (n = 76) with only 45.8% sensitivity and 96.2% specificity; missed cases had penetration depths indistinguishable from non-subsiders. Each 1 mm of early X-ray depth corresponded to 0.45 mm IVDH and 0.37° SL loss. Conclusions: An X-ray protrusion depth of 2.0 mm reliably identifies CT-confirmed early subsidence, providing a preliminary diagnostic cutoff for use when CT is unavailable. Intraoperative CT is highly specific but insensitive for late subsidence; meaningful risk stratification will require additional inputs. These hypothesis-generating findings warrant prospective validation.