Model-based dose calculation algorithms (MBDCAs) have recently emerged as potential successors to the highly practical, but sometimes inaccurate TG-43 formalism for brachytherapy treatment planning. So named for their capacity to more accurately calculate dose deposition in a patient using...

9 June 2014 in Medical Physics
Verified
Journal Article
Closed access
HMHali Morrison
Hali Morrison
GMGeetha Menon
Geetha Menon
RSRon S. Sloboda
Ron S. Sloboda

1 May 2022 in Practical Radiation Oncology
Verified
Journal Article
Closed access
MRMichael Roumeliotis
Michael Roumeliotis
HMHali Morrison
Hali Morrison
LCLeigh Conroy
Leigh Conroy
NBNathan Becker
Nathan Becker
NLNatalie Logie
Natalie Logie
SQSarah Quirk
Sarah Quirk

20 March 2017 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
BCBrie Cawston‐Grant
Brie Cawston‐Grant
HMHali Morrison
Hali Morrison
GMGeetha Menon
Geetha Menon
RSRon S Sloboda
Ron S Sloboda
Model-based dose calculation algorithms have recently been incorporated into brachytherapy treatment planning systems, and their introduction requires critical evaluation before clinical implementation. Here, we present an experimental evaluation of Oncentra® Brachy Advanced Collapsed-cone Engine (ACE) for a multichannel vaginal cylinder (MCVC) applicator using radiochromic film. A uniform dose of 500 cGy was specified to the surface of the MCVC using the TG-43 dose formalism under two conditions: (a) with only the central channel loaded or (b) only the peripheral channels loaded. Film measurements were made at the applicator surface and compared to the doses calculated using TG-43, standard accuracy ACE (sACE), and high accuracy ACE (hACE). When the central channel of the applicator was used, the film measurements showed a dose increase of (11 ± 8)% (k = 2) above the two outer grooves on the applicator surface. This increase in dose was confirmed with the hACE calculations, but was not confirmed with the sACE calculations at the applicator surface. When the peripheral channels were used, a periodic azimuthal variation in measured dose was observed around the applicator. The sACE and hACE calculations confirmed this variation and agreed within 1% of each other at the applicator surface. Additionally for the film measurements with the central channel used, a baseline dose variation of (10 ± 4)% (k = 2) of the mean dose was observed azimuthally around the applicator surface, which can be explained by offset source positioning in the central channel.

23 May 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
HMHali Morrison
Hali Morrison
GMGeetha Menon
Geetha Menon
MLMatthew P. Larocque
Matthew P. Larocque
BVBob van Veelen
Bob van Veelen
YNYury Niatsetski
Yury Niatsetski
RSRon S. Sloboda
Ron S. Sloboda

9 December 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
CLChloe Lim
Chloe Lim
SGSunita Ghosh
Sunita Ghosh
HMHali Morrison
Hali Morrison
DMDaniel Meyers
Daniel Meyers
ISIgor Stukalin
Igor Stukalin
APAliyah Pabani
Aliyah Pabani
The PACIFIC trial led to a new standard of care for patients with locally advanced lung cancer, but real-world practice has demonstrated that immune checkpoint inhibitor (ICI) pneumonitis can lead to significant clinical complications. This study aimed to examine the clinical predictors, outcomes, and healthcare utilization data in patients who received consolidation durvalumab. Using the Alberta Immunotherapy Database, NSCLC patients who received durvalumab in Alberta, Canada, from January 2018 to December 2021 were retrospectively evaluated. We examined incidence and predictive values of severe pneumonitis, with overall survival (OS) and time-to-treatment failure (TTF) using exploratory multivariate analyses. Of 189 patients, 91% were ECOG 0–1 and 85% had a partial response from chemoradiation prior to durvalumab. Median TTF and OS were not reached; 1-year OS was 82%. An amount of 26% developed any grade of pneumonitis; 9% had ≥grade 3 pneumonitis. Male gender and a pre-existing autoimmune condition were associated with severe pneumonitis. V20 was associated with any grade of pneumonitis. Pneumonitis development was found to be an independent risk factor for worse OS (p = 0.038) and TTF (p = 0.007). Our results suggest clinical and dosimetric predictive factors of durvalumab-associated pneumonitis. These results affirm the importance of careful patient selection for safe completion of consolidation durvalumab in real-world LA-NSCLC population.