This paper explores a computational approach to model multiphase heat transfer and fluid flow in a natural circulation loop utilizing nanofluids. We propose and implement an Euler–Euler framework in a CFD environment, incorporating an innovative boundary condition to preserve mass conservation during thermophoretic particle flux. The model’s accuracy is verified through a one-dimensional example, by comparing results against both an Euler–Lagrange model and an in-house finite volume solution. Experimental validation is conducted with aluminum oxide nanofluids at varying nanoparticle concentrations. We prepared the nanofluids and measured their thermophysical properties up to $$60^\circ$$ C. We assess the thermal performance of the nanofluid in natural circulation loop at different heating powers via experiment and numerical simulations. The findings reveal that the heat transfer enhancement offered by the nanofluid is modest, with minimal differences observed between the proposed Euler–Euler approach and a simpler single-phase model. The results underscore that while the Euler–Euler model offers detailed particle–fluid interactions, its practical thermal advantage is limited in this context.
The selection of a temperature probe for aerodynamic applications involves a critical trade-off between the measurement accuracy and structural robustness. While the existing literature typically treats thermal performance and structural limits as isolated problems, this study bridges this gap by introducing a novel coupled experimental framework in which the aerodynamic and structural performance of the probes are characterized and interpreted jointly. Three unshielded, cylindrical K-type thermocouples (diameters: D = 0.5, 1.0, and 1.5 mm) were tested in a freejet facility across a Mach number range of M = 0.05 to 0.50, corresponding to a probe Reynolds number range of ReD ≈ 500 to 16,200, at a free cantilever length of L = 70 mm for aerodynamic characterization and L = 20–70 mm for structural characterization. Tests were conducted at a total temperature of approximately To ≈ 291–294 K, continuously monitored throughout each run. The recovery factor was highest for the 0.5 mm probe (r ≈ 0.4–0.55) and comparable for the 1.0 mm and 1.5 mm probes (r ≈ 0.29–0.34), such that the largest diameter did not produce the lowest value. Structurally, the 0.5 mm probe reached its deflection limit at M ≈ 0.22, while the 1.0 mm probe remained stable to M ≈ 0.36, for a free length of 70 mm. By treating probe selection as a constrained selection problem rather than an ad hoc decision, this study provides a quantitative operational envelope—a critical, data-driven framework for researchers to balance sensor accuracy and physical viability in aerodynamic testing.
25 June 2026 in Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering