Yoichi Otomi

Dr. Yoichi Otomi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2015 in SpringerPlus
Verified
Journal Article
Open access
PDF file
TATakashi Abe
Takashi Abe
YMYoshifumi Mizobuchi
Yoshifumi Mizobuchi
KNKohei Nakajima
Kohei Nakajima
YOYoichi Otomi
Yoichi Otomi
SISaho Irahara
Saho Irahara
MHMasafumi Harada
Masafumi Harada
This study sought to determine the diagnostic utility of perfusion parameters derived from dynamic contrast-enhanced (DCE) perfusion MRI with a short acquisition time (approximately 3.5 min) in patients with glioma, brain metastasis, and primary CNS lymphoma (PCNSL). Twenty-six patients with 29 lesions (4 low-grade glioma, 13 high-grade glioma, 7 metastasis, and 5 PCNSL) underwent DCE-MRI in a 3 T scanner. A ROI was placed on the hotspot of each tumor in maps for volume transfer contrast K trans , extravascular extracellular volume V e , and fractional plasma volume V p . We analyzed differences in parameters between tumors using the Mann–Whitney U test. We calculated sensitivity and specificity using receiver operating characteristics analysis. Mean K trans values of LGG, HGG, metastasis and PCNSL were 0.034, 0.31, 0.38, 0.44, respectively. Mean Ve values of each tumors was 0.036, 0.57, 0.47, 0.96, and mean Vp value of each tumors was 0.070, 0.086, 0.26, 0.17, respectively. Compared with other tumor types, low-grade glioma showed lower K trans (P < 0.01, sensitivity = 88%, specificity = 100%) and lower V e (P < 0.01, sensitivity = 96%, specificity = 100%). PCNSL showed higher V e (P < 0.01, sensitivity = 100%, specificity = 88%), but the other perfusion parameters overlapped with those of different histology. Kinetic parameters derived from DCE-MRI with short acquisition time provide useful information for the differential diagnosis of brain tumors.

10 December 2018 in BMC Gastroenterology
Verified
Journal Article
Open access
PDF file
YOYoichi Otomi
Yoichi Otomi
HOHideki Otsuka
Hideki Otsuka
KTKaori Terazawa
Kaori Terazawa
MYMoriaki Yamanaka
Moriaki Yamanaka
YOYuki Obama
Yuki Obama
MHMasafumi Harada
Masafumi Harada
Blood loss from the gastrointestinal tract can be an acute and life-threatening event. For the treatment of gastrointestinal bleeding, it is important to accurately detect gastrointestinal bleeding and to localize the sites of bleeding. The purpose of this study was to retrospectively assess the capabilities of SPECT/CT in the diagnosis of gastrointestinal bleeding by a comparison with planar imaging alone as well as planar and SPECT. We conducted a retrospective analysis of 20 patients (21 examinations) who underwent gastrointestinal bleeding scintigraphy in the past 7 years and in whom the bleeding site was identified by endoscopy or capsule endoscopy, or in whom no evidence of gastrointestinal bleeding was identified during the clinical course. Five patients (5 examinations) were diagnosed by planar imaging (planar group). Eight patients (9 examinations) were diagnosed by planar imaging and SPECT (planar + SPECT group). Seven patients (7 examinations) were diagnosed by planar imaging and SPECT/CT (planar + SPECT/CT group). We calculated the diagnostic ability of each method in detecting the presence of bleeding, as well as the ability of each method to identify the sites of bleeding. The sensitivity, specificity, and accuracy of the methods were compared. The diagnostic ability of the three imaging methods in detecting the presence of gastrointestinal bleeding was as follows. Planar imaging showed 100% sensitivity (3/3), 100% specificity (2/2), and 100% accuracy (5/5). Planar + SPECT imaging showed 85.7% sensitivity (6/7), 100% specificity (2/2), and 88.9% accuracy (8/9). Planar + SPECT/CT imaging showed 100% sensitivity (6/6), 100% specificity (1/1), and 100% accuracy (7/7). The diagnostic ability of the three modalities in detecting the site of bleeding was as follows: planar, 33.3% (1/3); planar + SPECT, 71.4% (5/7); and planar + SPECT/CT, 100% (6/6). All 3 imaging methods showed good accuracy in detecting the presence of gastrointestinal bleeding. The addition of SPECT or SPECT/CT made the anatomical position of the uptake clear and contributed to the localization of the site of gastrointestinal bleeding. Planar + SPECT/CT imaging therefore showed the highest diagnostic ability for detecting the site of gastrointestinal bleeding.

26 July 2022 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
AKAtsuhiro Kanayama
Atsuhiro Kanayama
YTYuuki Tsuchihashi
Yuuki Tsuchihashi
YOYoichi Otomi
Yoichi Otomi
HEHideaki Enomoto
Hideaki Enomoto
YAYuzo Arima
Yuzo Arima
HWHaruhito Watase
Haruhito Watase
Purpose: We aimed to characterize novel coronavirus infections based on imaging [chest X-ray and chest computed tomography (CT)] at the time of admission. Materials and methods: We extracted data from 396 patients with laboratory-confirmed COVID-19 who were managed at 68 hospitals in Japan from January 25 to September 2, 2020. Case patients were categorized as severe (death or treatment with invasive ventilation during hospitalization) and non-severe groups. The imaging findings of the groups were compared by calculating odds ratios (ORs) and 95% confidence intervals (95% CIs), adjusted for sex, age, and hospital size (and radiographic patient positioning for cardiomegaly). Chest X-ray and CT scores ranged from 0 to 72 and 0 to 20, respectively. Optimal cut-off values for these scores were determined by a receiver-operating characteristic (ROC) curve analysis. Results: The median age of the 396 patients was 48 years (interquartile range 28–65) and 211 (53.3%) patients were male. Thirty-two severe cases were compared to 364 non-severe cases. At the time of admission, abnormal lesions on chest X-ray and CT were mainly observed in the lower zone/lobe. Among severe cases, abnormal lesions were also seen in the upper zone/lobe. After adjustment, the total chest X-ray and CT score values showed a dose-dependent association with severe disease. For chest X-ray scores, the area under the ROC curve (AUC) was 0.91 (95% CI = 0.86–0.97) and an optimal cut-off value of 9 points predicted severe disease with 83.3% sensitivity and 84.7% specificity. For chest CT scores, the AUC was 0.94 (95% CI = 0.89–0.98) and an optimal cut-off value of 11 points predicted severe disease with 90.9% sensitivity and 82.2% specificity. Cardiomegaly was strongly associated with severe disease [adjusted OR = 24.6 (95% CI = 3.7–166.0)]. Conclusion: Chest CT and X-ray scores and the identification of cardiomegaly could be useful for classifying severe COVID-19 on admission.

2 June 2016 in Annals of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
YOYoichi Otomi
Yoichi Otomi
TSTakayoshi Shinya
Takayoshi Shinya
HOHideki Otsuka
Hideki Otsuka
KTKaori Terazawa
Kaori Terazawa
SISaho Irahara
Saho Irahara
MHMasafumi Harada
Masafumi Harada

5 August 2022 in Nuclear Medicine Review
Verified
Journal Article
Closed access
PDF file
YOYoichi Otomi
Yoichi Otomi
YAYuta Arai
Yuta Arai
MOMaki Otomo
Maki Otomo
SISaho Irahara
Saho Irahara
KTKaori Terazawa
Kaori Terazawa
MHMasafumi Harada
Masafumi Harada
Background: In the daily clinical course, the liver uptake may seem to be increased in patients with renal failure. The purpose of this study was to investigate whether or not the FDG uptake of the liver, and the FDG uptake of blood pool which is generally used as a reference site as well as liver, is increased in patients with renal failure. Material and methods: We retrospectively analyzed 233 patients who underwent FDG positron emission tomography/computed tomography (PET/CT). Renal failure is defined as an estimated glomerular filtration rate (eGFR) < 60 mL/min/1.73 m2. We compared the FDG uptake in the liver and mediastinal blood pool of 67 patients with impaired renal function to that in 166 patients with a normal renal function (eGFR ≥ 60 mL/min/1.73 m2). Correlations between the liver or mediastinal blood pool FDG uptake and the eGFR were also analyzed by Spearman’s correlation test. Results: Maximum and mean standardized uptake values (SUVmax and SUVmean, respectively) of the liver and the SUVmean of the mediastinal blood pool were 3.48 ± 0.57, 2.56 ± 0.37, and 1.90 ± 0.28 in the impaired renal function group, respectively, and 3.13 ± 0.45, 2.29 ± 0.33, and 1.66 ± 0.23, in the normal group, respectively. The SUVmax and SUVmean of the liver and SUVmean of the mediastinal blood pool in the impaired renal function group were significantly higher than those in the normal group (p < 0.001, < 0.001, and < 0.001, respectively). The SUVmax and SUVmean of the liver and SUVmean of the mediastinal blood pool of patients showed a significant negative correlation with the eGFR (Spearman’s p = –0.25, –0.30, and –0.40, respectively, each p < 0.001). Conclusions: FDG uptake in both the liver and mediastinal blood pool was higher in patients with impaired renal function. Background: In the daily clinical course, the liver uptake may seem to be increased in patients with renal failure. The purpose of this study was to investigate whether or not the FDG uptake of the liver, and the FDG uptake of blood pool which is generally used as a reference site as well as liver, is increased in patients with renal failure. Material and methods: We retrospectively analyzed 233 patients who underwent FDG positron emission tomography/computed tomography (PET/CT). Renal failure is defined as an estimated glomerular filtration rate (eGFR) < 60 mL/min/1.73 m2. We compared the FDG uptake in the liver and mediastinal blood pool of 67 patients with impaired renal function to that in 166 patients with a normal renal function (eGFR ≥ 60 mL/min/1.73 m2). Correlations between the liver or mediastinal blood pool FDG uptake and the eGFR were also analyzed by Spearman’s correlation test. Results: Maximum and mean standardized uptake values (SUVmax and SUVmean, respectively) of the liver and the SUVmean of the mediastinal blood pool were 3.48 ± 0.57, 2.56 ± 0.37, and 1.90 ± 0.28 in the impaired renal function group, respectively, and 3.13 ± 0.45, 2.29 ± 0.33, and 1.66 ± 0.23, in the normal group, respectively. The SUVmax and SUVmean of the liver and SUVmean of the mediastinal blood pool in the impaired renal function group were significantly higher than those in the normal group (p < 0.001, < 0.001, and < 0.001, respectively). The SUVmax and SUVmean of the liver and SUVmean of the mediastinal blood pool of patients showed a significant negative correlation with the eGFR (Spearman’s p = –0.25, –0.30, and –0.40, respectively, each p < 0.001). Conclusions: FDG uptake in both the liver and mediastinal blood pool was higher in patients with impaired renal function.

3 November 2016 in Japanese Journal of Radiology
Verified
Journal Article
Closed access
PDF file
YOYoichi Otomi
Yoichi Otomi
TSTakayoshi Shinya
Takayoshi Shinya
NUNaoto Uyama
Naoto Uyama
YAYuta Arai
Yuta Arai
KMKanako Miyamoto
Kanako Miyamoto
MHMasafumi Harada
Masafumi Harada