Jingtian Bi

Dr. Jingtian Bi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JHJiawei Hu
Jiawei Hu
TWTong Wang
Tong Wang
ZWZengping Wang
Zengping Wang
JLJiuliang Liu
Jiuliang Liu
JBJingtian Bi
Jingtian Bi
The commutation failure of Line Commutated Converter-High Voltage Direct Current (LCC-HVDC) cannot be avoided. This paper presents a novel transient stability assessment approach for AC/DC hybrid system considering continuous commutation failure. First, the conception and mathematical background of Maximum Lyapunov Exponent (MLE) of switching system is introduced, and the switching compensation matrix is derived. Next, the switching system model of AC/DC hybrid system considering continuous commutation failure caused by AC faults is established. On the basis of switching compensation, the MLE of switching system is calculated accurately, and the MLE based criteria are proposed to assess the transient stability of the switching system. Finally, the modified 39-bus system with LCC-HVDC added and the real power system are used as test systems to investigate the validity and effectiveness of the proposed transient stability assessment approach.

12 February 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
WDWenjuan Du
Wenjuan Du
JBJingtian Bi
Jingtian Bi
HWHaifeng Wang
Haifeng Wang
This paper investigates the damping degradation of power system low-frequency electromechanical oscillations caused by the open-loop modal resonance. The investigation is based on a closed-loop interconnected model of a multi-machine power system, wherein, the electromechanical dynamics of a synchronous generator being examined and the remainder of power system are modelled as two separate open-loop subsystems. The open-loop modal resonance is the closeness of an open-loop electromechanical oscillation mode of the synchronous generator to an open-loop electromechanical oscillation mode of the power system on the complex plane. Theoretical analysis indicates that when the open-loop modal resonance happens, the dynamic interactions between the synchronous generator and the remainder of power system are strong and degrade the damping of the low-frequency electromechanical oscillations. Test results in two example power systems show that the synchronous generator geographically far away took part in the local low-frequency electromechanical oscillations when the open-loop modal resonance occurred. The macroscopic effect of the open-loop modal resonance was the expansion of area on the complex plane where the electromechanical oscillation modes located, when the scale of the power systems increased.

21 February 2020 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
TWTong Wang
Tong Wang
JYJing Yang
Jing Yang
MPMalhar Padhee
Malhar Padhee
JBJingtian Bi
Jingtian Bi
APAnamitra Pal
Anamitra Pal
ZWZengping Wang
Zengping Wang
This study presents a robust, coordinated control methodology for damping sub‐synchronous oscillations (SSOs) while considering power output variations from multiple wind farms. The proposed damping control strategy utilises the mixed H 2 / H ∞ control with regional pole placement to suppress the oscillations. For ensuring applicability over a wider operating range, the convex polytopic theory is utilised by using different operating points as the vertices of a convex polytope. The centralised, coordinated controller for damping SSOs is designed using linear matrix inequalities. Furthermore, unmeasurable state variables, if present, are represented by corresponding output variables. The damping signal is implemented as active power and reactive power modulation of the rotor‐side converter of the doubly fed induction generators. A 4‐machine, 2‐area system and a 39‐machine New England system are used to demonstrate the performance of the proposed control. The simulation results show that the polytopic controller can not only provide requisite damping to the SSO modes of interest, but also has good control performance when the wind power outputs change over a wide range.

24 September 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
WDWenjuan Du
Wenjuan Du
JBJingtian Bi
Jingtian Bi
HWHaifeng Wang
Haifeng Wang
JYJun Yi
Jun Yi
This study examines a modal condition to cause inter‐area, low‐frequency, electromechanical power oscillations in an interconnected power system with two subsystems. The modal condition being examined is the closeness of two electromechanical oscillation modes from each subsystem on the complex plane, which is referred to as open‐loop modal resonance. The analysis in this study indicates that under the condition of open‐loop modal resonance, the electromechanical oscillation modes of the interconnected power system are located at approximately opposite positions on the complex plane with respect to the resonant electromechanical oscillation modes of the subsystems. Hence, when open‐loop modal resonance occurs, one electromechanical oscillation mode of the interconnected power system must have reduced damping. In this study, the damping reduction in the inter‐area, low‐frequency power oscillations caused by open‐loop modal resonance is demonstrated using example power systems. An incident of inter‐area, low‐frequency electromechanical power oscillations that occurred in an actual large‐scale power system in China is examined. The examination results indicate that the poorly damped, inter‐area, low‐frequency power oscillation incident was caused by open‐loop modal resonance.

29 July 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
LWLetian Wang
Letian Wang
SXShiyun Xu
Shiyun Xu
HSHuadong Sun
Huadong Sun
JBJingtian Bi
Jingtian Bi
PHPeng Han
Peng Han
The coupling between the synchronization loop (SC) and DC voltage control loop (DVC) of a virtual synchronous generator (VSG) controlled grid-forming converter (GFM) is prone to cause multi-modal low-frequency oscillations (LFO). These multi-modal oscillations consist of SC dominant LFO (SC- LFO) and DVC dominant LFO (DVC-LFO). In this paper, we investigate the mutual damping repulsion effect of multi-modal LFOs and reveal the mechanisms behind such phenomena by means of the damping torque method in the frequency domain. Analytical studies have found that, as the self-damping levels of SC and DVC increase, they exert incremental negative damping torque on each other. This interaction leads to an inverse variation in damping regulation of SC-LFO and DVC-LFO during the tuning of SC or DVC dynamic, ultimately causing the mutual repulsion phenomenon. Moreover, it has been proved that virtual damping in SC is not universally effective for LFOs stabilizing in GFM converter. Increased virtual damping ensures SC-LFO stability but may induce instability of DVC-LFO due to mutual repulsion. Finally, the analytical results are corroborated by both eigenvalue and time domain analysis.