Hakan Güneyli

Prof. Dr. Hakan Güneyli

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2003 in Tectonophysics
Verified
Journal Article
Closed access
HCHasan Cetin
Hasan Cetin
HGHakan Güneyli
Hakan Güneyli
LMLarry Mayer
Larry Mayer

1 February 2017 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
HGHakan Güneyli
Hakan Güneyli
SKSüleyman Karahan
Süleyman Karahan
AGAslιhan Güneyli
Aslιhan Güneyli
NYNil Yapιcι
Nil Yapιcι
In this paper, water content and temperature effect on the ultrasonic pulse velocity (UPV) of concrete was investigated. A series of tests were performed to examine the relationship between water content and UPV of concrete with different aggregate mixture proportions. Cube test specimens were made of concrete with water-cement ratio of 0.5. The concrete specimens were immersed in water for 90 days to saturate them. To measure the effect of different water contents on UPV, the test specimens were dried gradually to change the amount of water between measurements. This process was repeated until the concrete pieces was completely dried and weight no longer changed. The water content could be changed from about 6 to 0%. Following, another test procedure was conducted to research the relationship between temperature and UPV. To measure the influence of various temperature on UPV, completely dried concrete specimens were firstly cooled to –18°C and gradually heated to +180°C. In these two different procedures, the UPV values corresponding water content and temperature in the relevant ranges were periodically measured. The test results indicate that the increase in both water content and temperature increases almost linearly UPV of concrete. Based on correlation derived from the test data, irrespective of concrete properties a further increase in both water content of 1% and temperature of 10°C increases UPV of average 160 and 34 m/s, respectively. As overall assessment, this study demonstrates that the UPV is a function of both water content and temperature, and the changing of these two parameters has an important influence on ultrasonic pulse velocity of concrete.

24 December 2015 in Bulletin of Engineering Geology and the Environment
Verified
Journal Article
Closed access
PDF file
HGHakan Güneyli
Hakan Güneyli
TRTolga Rüşen
Tolga Rüşen

16 February 2008 in Bulletin of Engineering Geology and the Environment
Verified
Journal Article
Closed access
PDF file
EYE. Yaşar
E. Yaşar
YEY. Erdoğan
Y. Erdoğan
HGHakan Güneyli
Hakan Güneyli

1 October 2007 in Engineering Geology
Verified
Journal Article
Closed access
CKC. Kayadelen
C. Kayadelen
OSO. Sivrikaya
O. Sivrikaya
TTT. Taşkıran
T. Taşkıran
HGHakan Güneyli
Hakan Güneyli

1 May 2016 in Quaternary International
Verified
Journal Article
Closed access
EMEngin Meriç
Engin Meriç
EÖErtuğ Öner
Ertuğ Öner
NANiyazi Avşar
Niyazi Avşar
ANAtike Nazik
Atike Nazik
HGHakan Güneyli
Hakan Güneyli
FDFeyza Dinçer
Feyza Dinçer