Neutron capture yields and transmission ratios of 93Nb were measured by applying the time-of-flight method using the Accurate Neutron-Nucleus Reaction measurement Instrument of the Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex. Nb metal foils were used as samples. Germanium gamma-ray and Li-glass neutron detectors were used for capture yields and transmission ratio measurements, respectively. The pulse height weighting technique was applied to deduce the capture cross-sections from 0.01 to 400 eV, and the thermal-neutron capture cross-section was determined to be 0.97 ± 0.11 b. The total cross-sections were derived from transmission ratios ranging from 0.2 to 400 eV. The resonance parameters of 93Nb below 400 eV were determined based on the obtained capture cross-sections and transmission ratios using the resonance analysis code, REFIT, and compared with the parameters given by past measurements and the evaluated nuclear data library, JENDL-4.0.
12 August 2019 in Journal of Nuclear Science and Technology
The neutron capture cross-section of 237Np has been measured in the neutron energy region from 10 meV to 500 eV. A neutron time-of-flight method was employed using the NaI(Tl) spectrometer in the ANNRI beamline at the Japanese Proton Accelerator Research Complex (J-PARC). The experimental capture yield was derived using the pulse-height weighting technique and an energy-dependent cross-section was obtained relative to the incident neutron spectrum derived from a 10B(n, )7Li reaction yield. The absolute cross-section was determined by normalizing the results to JENDL-4.0 cross-section data at the first resonance of 237Np. The thermal cross-section was measured to be 177.6 ± 3.8 b. The resolved resonance region was analyzed with the REFIT code. An average radiation width = 40.3 ± 0.5 meV, a mean level spacing D0 = 0.60 ± 0.02 eV and a neutron strength function 104S0 = 1.02 ± 0.12 were obtained.
15 December 2022 in Journal of Nuclear Science and Technology
Neutron total and capture cross–section measurements of 155Gd and 157Gd were performed with Li-glass detectors and a NaI(Tl) spectrometer in the ANNRI at the MLF of the J-PARC. The neutron total cross sections were determined in the energy region from 5 to 100 meV, and those at the thermal neutron energy were obtained to be 59.4 1.7 and 251.9 4.6 kilobarn for 155Gd and 157Gd, respectively. The neutron capture cross sections were determined in the energy region from 3.5 to 100 meV with an innovative method, and those at the thermal energy were obtained as 59.0 2.5 and 247.4 3.9 kilobarn for 155Gd and 157Gd, respectively. The present total and capture cross sections agree well within the standard deviations. The results for 155Gd were found to be consistent with the values in JENDL-4.0 and the experimental data given by Møller et al., Mastromarco et al. and Leinweber et al. Those for 157Gd agreed with the evaluated data in JENDL-4.0 and the experimental data by Møller et al. and Mastromarco et al. However, they disagree (11% larger) with the experimental result by Leinweber et al.
1 July 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Neutron capture cross-section measurements for Np have been conducted with the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) at the Materials and Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC) using neutrons with energy ranging from thermal energy to 1 MeV. A time-of-flight (TOF) method using a NaI(Tl) detector was employed and the data were analyzed based on the pulse-height weighting technique in order to derive the neutron capture cross-section. The absolute capture cross-section was determined using the first resonance from JENDL-4.0 together with the total neutron flux derived from a Au sample measurement in which the first resonance was completely saturated. Both normalization techniques present agreement within 1 . The present results are also compared evaluated data libraries. There is a discrepancy of 10–25 discrepancy from 0.5 to 20 keV with JENDL-4.0. Nonetheless, above this energy JENDL-4.0 seems to reproduce the present data better as the results agree within uncertainties up to 500 keV. The cross-section results contain uncertainties below 4 from 0.5 to 30 keV. However, the total uncertainty increases to over 8 above 30 keV. Along with the cross-section measurement, theoretical calculations with the CCONE code were performed to reproduce the present results.
2 May 2022 in Journal of Nuclear Science and Technology
A neutron monitoring detection system was developed for neutron capture cross-section measurement using a spallation neutron source. A combination of a plastic scintillator and a thin 6 LiF foil was adopted for the detector. The detector system was tested to study the feasibility of the system. Neutron irradiation experiments were conducted with the Accurate Neutron-Nucleus Reaction Measurement Instrument in the Materials and Life Science facility of the Japan Proton Accelerator Research Complex. A neutron time-of-flight spectrum was successfully measured without significant count loss or detector paralysis. GRAPHICAL ABSTRACT