Even in a well-functioning total hip replacement, significant peri-implant bone resorption can occur secondary to stress shielding. Stress shielding is caused by an undesired mismatch of elastic modulus between the stiffer implant and the adjacent bone tissue. To address this problem, we present here a microarchitected hip implant that consists of a three-dimensional (3D) graded lattice material with properties that are mechanically biocompatible with those of the femoral bone. Asymptotic homogenization (AH) is used to numerically determine the mechanical and fatigue properties of the implant, and a gradient-free scheme of topology optimization is used to find the optimized relative density distribution of the porous implant under multiple constraints dictated by implant micromotion, pore size, porosity, and minimum manufacturable thickness of the cell elements. Obtained for a 38-year-old patient femur, bone resorption is assessed by the difference in strain energy between the implanted bone and the intact bone in the postoperative conditions. The numerical results suggest that bone loss for the optimized porous implant is only 42% of that of a fully solid implant, here taken as benchmark, and 79% of that of a porous implant with uniform density. The architected hip implant presented in this work shows clinical promise in reducing bone loss while preventing implant micromotion, thereby contributing to reduce the risk of periprosthetic fracture and the probability of revision surgery.
1 September 2018 in Computer Methods in Applied Mechanics and Engineering
Polymer degradation is a common problem in the extrusion process. In this work, Raman spectroscopy, a robust, rapid, and non-destructive tool for in-line monitoring, was utilized to in-line monitor the degradation of polypropylene (PP) under multiple extrusions. Raw spectra were pretreated by chemometrics methods to extract variations of spectra and eliminate noise. The variation of Raman intensity with the increasing number of extrusions was caused by the scission of PP chains and oxidative degradation, and the variation trend of Raman intensity indicated that long chains were more likely to be damaged by the extrusion. For the quantitative analysis of degradation, the partial least square was used to build a model to predict the degree of PP degradation measured by gel permeation chromatography (GPC). For the calibration set, the coefficient of determination (R2) and the root mean square error of cross-validation (RMSECV) were 0.9859 and 1.2676%, and for the prediction set, R2 and the root mean square error of prediction (RMSEP) were 0.9752 and 1.7228%, which demonstrated the accuracy of the proposed model. The in-line Raman spectroscopy combined with the chemometrics methods was proved to be an accurate and highly effective tool, which can monitor the degradation of polymer in real time.