Ali Akbar Abdoos

Dr. Ali Akbar Abdoos


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in Energy
Verified
Journal Article
Closed access
AAAli Akbar Abdoos
Ali Akbar Abdoos
HAHatef Abdoos
Hatef Abdoos
JKJavad Kazemitabar
Javad Kazemitabar
MMMohammad Mehdi Mobashsher
Mohammad Mehdi Mobashsher
HKHooman Khaloo
Hooman Khaloo

6 June 2023 in IEEE Systems Journal
Verified
Journal Article
Closed access
MMMohammad Mehdi Mobashsher
Mohammad Mehdi Mobashsher
AAAli Akbar Abdoos
Ali Akbar Abdoos
SHSeyyed Mehdi Hosseini
Seyyed Mehdi Hosseini
SHSayyed Mohammad Hashemi
Sayyed Mohammad Hashemi
MSMajid Sanaye-Pasand
Majid Sanaye-Pasand
Distance relay based pilot protection schemes are commonly employed in industrial relays to provide fast tripping of the faulty transmission lines. However, the probable communication link failure or interruption can make these schemes ineffective. Therefore, some non-pilot methods are addressed in the technical literature which cannot offer an appropriate performance in the presence of inverter-based resources (IBRs) owing to the unconventional fault behavior of IBRs as compared with that of synchronous generators. Thus, an analytical non-pilot method is established for the accelerated tripping (AT) of the second zone of distance relay in the presence of IBRs. At the first place with the proposed method, the faulted phase is identified through a fault classification scheme. Within the second phase, using the strength of the variations existing in the negative and zero sequence components of both voltage and current signals, the remote breaker status is realized. Finally, according to the remote breaker status, the AT or delayed tripping decision is decided. Performance of the established methodology is examined for different simulation scenarios, such as different fault locations as well as fault resistances, employing the PSCAD/EMTDC software. The obtained promising results obviously approve the efficiency of the proposed framework.

19 December 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
MMMohammad Mehdi Mobashsher
Mohammad Mehdi Mobashsher
SHSeyyed Mehdi Hosseini
Seyyed Mehdi Hosseini
AAAli Akbar Abdoos
Ali Akbar Abdoos
SHSayyed Mohammad Hashemi
Sayyed Mohammad Hashemi
MSMajid Sanaye-Pasand
Majid Sanaye-Pasand
HMHasan Mehrjerdi
Hasan Mehrjerdi

25 February 2025 in IEEE Access
Verified
Journal Article
Open access
MMMohammad Mehdi Mobashsher
Mohammad Mehdi Mobashsher
SHSeyyed Mehdi Hosseini
Seyyed Mehdi Hosseini
AAAli Akbar Abdoos
Ali Akbar Abdoos
SHSayyed Mohammad Hashemi
Sayyed Mohammad Hashemi
MSMajid Sanaye-Pasand
Majid Sanaye-Pasand
MAMaher Azzouz
Maher Azzouz
Fault type classification (FTC) is a major unit of industrial distance relays that affects some other protective schemes such as single-pole tripping and reclosing, fault location and etc. Traditional FTC techniques make use of either phase changes between current symmetrical components or magnitude differences between superimposed currents. Since inverter-based resources (IBRs) have different current signatures than those of synchronous generators, conventional FTC approaches suffer from misrecognition when applied to a transmission line emanating from an IBR. The fault current contribution of IBRs is determined by the host grid code (GC) and the internal controller. Therefore, this paper demonstrates the limitations of the conventional FTC methods employed in industrial applications for protection of lines that originate from IBRs under modern host GCs. First, the influence of various GCs on the classic FTC techniques is analyzed based on the negative-sequence control strategies. Then, some experimental tests are executed to evaluate the accuracy of industrial FTC methods in the attendance of IBRs. After that, various newly proposed FTC methods in the presence of IBRs are studied, and their advantages and disadvantages are discussed. Lastly, potential research gaps in the area of FTC with IBRs are noted for further study and investigation in academic circles.

1 January 2022 in International Journal of Engineering
Verified
Journal Article
Closed access
PDF file
ABA. H. Z. Bkhaitawi
A. H. Z. Bkhaitawi
AAAli Akbar Abdoos
Ali Akbar Abdoos
AEA. Ebadi
A. Ebadi
The ground differential (GD) relay is used to detect internal ground faults on the power transformer windings and terminals. In fact, this relay is employed as a complement to the phase differential (PD) relay. However, its stability is affected by magnetic saturation in current transformers (CTs) cores so that the spurious differential current caused by CT saturation may lead to the relay malfunction. In this paper, by modifying the restraining current definition in a conventional method, an adaptive restrain method is proposed. To evaluate the proposed method performance compared with conventional method, a real 230/63 kV power transformer under a large number of internal fault, external fault and in rush current cases are simulated in PSCAD/EMTDC environment. It is worth noting that Jiles-Atherton (JA) model is utilized to simulate CTs. MATLAB software is used to implement and analyze these methods using obtained simulation. Obtained results show that the proposed method is quite superior to the conventional method, despite its simplicity.

1 August 2020 in Technology and Economics of Smart Grids and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AAAmir Hossein Azimi
Amir Hossein Azimi
AAAli Akbar Abdoos
Ali Akbar Abdoos