Vladislav Filatov

Mr. Vladislav Filatov

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in International Journal of Engineering
Verified
Journal Article
Open access
PDF file
IRI. I. Rastvorova
I. I. Rastvorova
VFVladislav Filatov
Vladislav Filatov
SVS. A. Vilkov
S. A. Vilkov
Today, Russia and the rest of the world are experiencing an increase in the production and reserves of heavy hydrocarbons (HC). This poses a problem in terms of both technical and financial needs, compared to conventional oil reserves. In this context, one of the key objectives for the advancement of the mineral resources sector is the enhancement of oil field diagnostic systems. This enables the "digitalization" of oil fields and processes related to extraction and transportation. The aim of the work is to analyze the current state of infrared (IR) oil diagnostic devices, existing problems and ways to optimize them, with special attention to the preliminary ultrasonic (US) treatment of highly viscous samples. This study was able to confirm the hypothesis that US treatment of resinous oil samples leads to an increase in the signal-to-noise ratio (SNR) of the IR diagnostic system. The highest efficiency of US treatment was recorded at a point (15°C; 15 min), where the increment of Iout was 51.36 % relative to untreated oil. The optimal time for US treatment based on effect on chemical composition of oil is: t < 9 min at T = 15°C, t < 6 min at T = 25°C, and t < 3 min at T = 35°C. Despite positive results, authors emphasize problems with uneven distribution of US vibrations and need for further research on paraffinic oil.


14 June 2026 in Power engineering: research, equipment, technology
Verified
Journal Article
Closed access
VFVladislav Filatov
Vladislav Filatov
IRI. I. Rastvorova
I. I. Rastvorova
THE RELEVANCE of the research lies in the development of methods for analyzing high-viscosity oil, whose share in world reserves and production is continuously growing. Accurate rapid analysis of the composition of such oil is necessary to optimize its production, transportation, and selection of chemical additives that increase mobility. However, application of the classical Bouguer-Lambert-Baer (BLB) law is difficult due to strong scattering of radiation and nonlinearity of optical response caused by complex multicomponent structure of high viscosity oil. THE PURPOSE is to develop a modified model of BLB law that takes into account rheological properties, and light scattering by asphaltene-resinous aggregates, and propose new model linking effective absorption coefficient to structural parameters of oil. METHODS. To substantiate the effectiveness of ultrasonic treatment as a method for sample preparation to improve the linearity of an oil medium, we used theoretical modeling and mechanisms for ultrasonic processing and its effects on optical properties. RESULTS. We show that consideration of rheological properties and light scattering is essential for an adequate description of the transmission of infrared (IR) radiation through viscous oil. The proposed modification to the BLB law incorporates additional terms to account for optical density due to particle scattering. Ultrasonic treatment reduces viscosity and heterogeneity, improving the transmission of IR radiation, which justifies its effectiveness. CONCLUSION. Integrating rheological factors into the BLB model and using ultrasonic preparation improves the accuracy of IR analysis of viscous oils. This will make it possible to more reliably determine the functional composition of high-viscosity oils in order to solve problems of increasing oil recovery, optimizing processes, and pipeline transport safety. Ultrasonic treatment provides a non-reactive reduction in viscosity and scattering, making it a promising method for sample preparation for rapid analysis.

27 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
VFVladislav Filatov
Vladislav Filatov
IRIrina Rastvorova
Irina Rastvorova
FCFedor Chmilenko
Fedor Chmilenko
Heavy and highly viscous oils account for a significant proportion of the world’s hydrocarbon reserves. The development of these reserves in harsh climates is associated with technological risks due to paraffin deposits and equipment corrosion. Ensuring reliable transportation requires operational monitoring of the physical and chemical properties of fluids directly at the wellhead. Traditional laboratory methods such as SARA fractionation and gas chromatography (GC) are time-consuming and can yield to distortions in the sample composition during transportation. Field optical methods, such as an infrared (IR) spectroscopy are complicated by the optical heterogeneity of crude oils due to emulsified water, supramolecular associations of resins, asphaltenes, and paraffins. In this paper, ultrasonic (US) sample preparation for high-viscosity oils is justified as a method for increasing the reliability and information content of field IR spectroscopic analysis by unmasking the diagnostic extrema of absorption bands that are initially distorted by emulsified water, baseline scattering, and radiation scattering from large resin–asphaltene–paraffin aggregates. The technique is based on cavitation-induced destruction of emulsion shells and disaggregation of the structural framework without volume thermal heating. Experimental data obtained from watered high-viscosity oil has shown that 9 min of the US exposure reduces the light scattering index Itrs by 92.83%, bringing the system into a less heterogeneous state. Statistical correlation analysis confirmed that emulsions and aggregates are the main scattering centers, and their destruction correlates directly with the transparency of the medium. Stability of spectral indices ICH3/CH2, Ifoc and IC=O indicates the absence of chemical degradation or oxidation at the US exposure intensity of 0.12 W/mL, confirming the physical nature of the effect. The proposed method makes it possible to implement automated monitoring of the properties of high-viscosity oil directly at the wellhead, minimizing logistic costs and risks of the sample degradation. The practical significance of the proposed method is to improve the reliability and information content of wellhead monitoring by reducing optical heterogeneity and making diagnostic significant IR absorption extremes more distinguishable for further interpretation.

11 June 2026 in Electronics
Verified
Journal Article
Open access
PDF file
IRIrina Rastvorova
Irina Rastvorova
AKAnastasia Kiseleva
Anastasia Kiseleva
VFVladislav Filatov
Vladislav Filatov
FCFedor Chmilenko
Fedor Chmilenko
YPYuriy Yurievich Perevalov
Yuriy Yurievich Perevalov
Against the background of observed climate change, which increases the risk of glacier-system degradation and the formation of hidden crevasses, the development of lightweight, wideband, and highly directional antenna systems has become a key factor in ensuring the safety of logistics operations and enhancing the spatial resolution and interpretability of ground-penetrating radar monitoring of near-surface snow–ice layers. The effectiveness of such systems is largely determined by the characteristics of the antenna unit, including the operating frequency band, gain, radiation pattern, weight, and resilience under extreme climatic conditions. The aim of this review is to provide a systematic analysis of modern Vivaldi antenna designs and Vivaldi-based antenna arrays, as well as to assess their prospects for application in X-band ground-penetrating radar systems for probing Antarctic snow-ice media. The paper considers the main types of ground-penetrating radar (GPR) antennas, their advantages and limitations, substantiates the priority of detecting hazardous near-surface inhomogeneities, and analyzes the capabilities of the X-band for the high-resolution identification of these inhomogeneities. Particular attention is paid to modern modifications of Vivaldi antennas, including antipodal, balanced, director-loaded, metamaterial-based, and array configurations. The analysis shows that Vivaldi antennas represent a promising basis for lightweight, wideband, and directional GPR systems; however, they require further improvement in terms of gain enhancement, sidelobe and back-lobe suppression, radiation-pattern stabilization, and adaptation to Antarctic operating conditions. Future research should focus on the development of adaptive and phased Vivaldi arrays, the use of metamaterials, Electromagnetic Band-Gap/Frequency-Selective Surfaces (EBG/FSS) structures, and director elements, the creation of lightweight, frost-resistant substrate materials, the advancement of multi-polarization multiple-input multiple-output (MIMO) systems, and the integration of antenna arrays with synthetic aperture radar (SAR) processing adapted to a multilayer snow–ice medium.

26 May 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
IRIrina Rastvorova
Irina Rastvorova
AKAnastasia Kiseleva
Anastasia Kiseleva
VFVladislav Filatov
Vladislav Filatov
FCFedor Chmilenko
Fedor Chmilenko
YPYuriy Yurievich Perevalov
Yuriy Yurievich Perevalov
Against the background of observed climate change, which increases the risk of glacier-system degradation and the formation of hidden crevasses, the development of lightweight, wideband, and highly directional antenna systems has become a key factor in ensuring the safety of logistics operations and enhancing the spatial resolution and interpretability of ground-penetrating radar monitoring of near-surface snow–ice layers The effectiveness of such systems is largely determined by the characteristics of the antenna unit, including the operating frequency band, gain, radiation pattern, weight, and resilience under extreme climatic conditions. The aim of this review is to provide a systematic analysis of modern Vivaldi antenna designs and Vivaldi-based antenna arrays, as well as to assess their prospects for application in X-band ground-penetrating radar systems for probing Antarctic snow-ice media. The paper considers the main types of GPR antennas, their advantages and limitations, substantiates the priority of detecting hazardous near-surface inhomogeneities, and analyzes the capabilities of the X-band for the high-resolution identification of these inhomogeneities. Particular attention is paid to modern modifications of Vivaldi antennas, including antipodal, balanced, director-loaded, metamaterial-based, and array configurations. The analysis shows that Vivaldi antennas represent a promising basis for lightweight, wideband, and directional GPR systems; however, they require further improvement in terms of gain enhancement, sidelobe and back-lobe suppression, radiation-pattern stabilization, and adaptation to Antarctic operating conditions. Future research should focus on the development of adaptive and phased Vivaldi arrays, the use of metamaterials, EBG/FSS structures, and director elements, the creation of lightweight, frost-resistant substrate materials, the advancement of multi-polarization MIMO systems, and the integration of antenna arrays with SAR processing adapted to a multilayer snow–ice medium.