Background: Serum sodium is an important laboratory value in hospitalized patients, but its relationship with mortality in patients with cardiogenic shock complicated by acute myocardial infarction (AMI-CS) has not been evaluated. We assessed the association between admission serum sodium and mortality in AMI-CS. Methods: A total of 312 patients with AMI-CS treated at a single center were retrospectively enrolled in this study. The primary endpoint was all-cause mortality. Patients were divided into three groups by tertiles based on admission serum sodium levels. The prognostic value of admission serum sodium levels was evaluated using Kaplan–Meier survival curves and Cox regression. Restricted cubic splines, subgroup analyses, and sensitivity analyses were also performed. Results: Over a follow-up of 4.5 years, 51.9% of enrolled patients died. In unadjusted analyses, higher admission serum sodium was associated with mortality, as well as rates of sepsis, dialysis, and brain injury during hospitalization, and patients with sodium > 141.2 mmol/L had higher short-term mortality; a J-shaped relationship was observed on unadjusted spline analysis. However, this association did not persist after adjustment for shock severity: the fully adjusted hazard ratio per 1 mmol/L was 1.02 (95% CI 0.98–1.06, p = 0.46) for long-term and 1.03 (95% CI 0.98–1.07, p = 0.28) for 30-day mortality, and the spline association was no longer significant (p for overall association = 0.40; p for nonlinearity = 0.33). Adding severity variables one at a time showed that the association was abolished specifically by arterial lactate. Conclusions: Higher admission serum sodium is associated with mortality in AMI-CS, but this association is largely explained by concurrent shock severity, particularly hyperlactatemia. Admission sodium may serve as an early, readily available integrative marker of shock severity for risk stratification, but whether sodium-directed treatment strategies affect outcomes requires prospective study.
Background: Right-to-left shunting through a patent foramen ovale (PFO) is an underrecognized yet potentially reversible cause of refractory hypoxemia, particularly in patients with right ventricular dysfunction. This case report describes heart-rate-dependent right-to-left shunting through a PFO causing refractory hypoxemia in a patient with inflammatory cardiomyopathy and severe right ventricular dysfunction, presumably arising from biventricular output mismatch. Case Presentation: We report the case of a 41-year-old male with inflammatory cardiomyopathy and a recently implanted single-chamber pacemaker (VVI mode, lower rate limit 50 bpm), admitted for decompensated heart failure. After initial clinical improvement with guideline-directed therapy, the patient’s intrinsic heart rate declined, and ventricular pacing at 50 bpm became the dominant rhythm. He subsequently developed refractory hypoxemia unresponsive to mechanical ventilation. Systematic hemodynamic assessment was performed using transthoracic echocardiography and thoracic electrical bioimpedance (TEB) monitoring at different pacing rates. Results: Echocardiographic evaluation revealed dynamic interatrial shunting through a PFO with the following characteristics: left-to-right at a pacing rate of 80 bpm and right-to-left at 50 bpm. Hemodynamic and echocardiographic data suggested that bradycardia induced biventricular output mismatch—left ventricular outflow tract velocity–time integral (VTI) increased by approximately 38% (from 17.5 cm to 24.1 cm), whereas right ventricular outflow tract VTI increased by only approximately 4% (13.3 cm vs. 13.8 cm). This mismatch likely resulted in relative elevation of right atrial pressure, thereby driving right-to-left shunting through the PFO. Increasing the pacing rate to 80 bpm reversed the shunt direction, normalized oxygenation, and facilitated successful extubation. Conclusions: This case suggests that in patients with severe right ventricular dysfunction, bradycardia may induce biventricular output mismatch with substantially greater left than right ventricular stroke volume augmentation, and presumably relative elevation of right atrial pressure, potentially leading to dynamic right-to-left shunting through a PFO. For such patients with unexplained hypoxemia, the possibility of dynamic PFO shunting should be considered. Appropriately increasing the pacing rate may help restore biventricular output matching, reverse shunt direction, and improve oxygenation; individualized heart rate management strategies warrant clinical consideration.