Ponte osteotomy is an increasingly popular technique for multiplanar correction of adolescent idiopathic scoliosis. Prior cadaveric studies have suggested that sequential posterior spinal releases increase spinal flexibility. Here we introduce a novel technique involving a sequential approach to the Ponte osteotomy that minimizes spinal canal exposure. One fresh-frozen adult human cadaveric thoracic spine specimen with 4 cm of ribs was divided into three sections (T1–T5, T6–T9, T10–L1) and mounted for biomechanical testing. Each segment was loaded with five Newton meters under four conditions: baseline inferior facetectomy with supra/interspinous ligament release, superior articular process (SAP) osteotomy in situ, spinous process (SP) osteotomy in situ, and complete posterior column osteotomy with SP/SAP excision and ligamentum flavum release (PCO). Compared to baseline, in situ SAP osteotomy alone provided 3.5%, 7.6%, and 7.2% increase in flexion/extension, lateral bending, and axial rotation, respectively. In situ SP osteotomy increased flexion/extension, lateral bending, and axial rotation by 15%, 18%, and 10.3%, respectively. PCO increased flexion/extension, lateral bending, and axial rotation by 19.6%, 28.3%, and 12.2%, respectively. Our report introduces a novel approach where incremental increases in range of motion can be achieved with minimal spinal canal exposure and demonstrates feasibility in a cadaveric model.
This study aimed to compare the biomechanical strength and stiffness of the native posteromedial and posterolateral meniscotibial ligament complex (MTLC) to suture anchor repair of the MTLC. Biomechanical testing was performed on 24 fresh-frozen pediatric human knees. Four conditions were tested: native posteromedial MTLC (n = 14), native posterolateral MTLC (n = 14), posteromedial MTLC repair (n = 5), and posterolateral MTLC repair (n = 5). Load to failure and stiffness were measured for all conditions. The load to failure for the posteromedial suture anchor construct was significantly higher than that for the native MTLC (p < 0.01). The posterolateral suture anchor construct had a significantly greater stiffness than the native MTLC (p = 0.03). Posterolateral MTLC load to failure and posteromedial MTLC stiffness were similar between native tissue and suture-anchor repair. All native MTLCs failed at the meniscus-MTLC interface. The suture anchor groups had various failure modes, including suture pullout and breakage. Suture anchor fixation can match or exceed the native tissue's load to failure. This study supports the viability of suture anchor-based posterior MTLC repairs of the medial and lateral meniscus in pediatric bone.
Background/Objectives: Hamstring tendon (HT) autografts are commonly used for anterior cruciate ligament reconstruction (ACLR), traditionally combining semitendinosus and gracilis (ST + GR) tendons to achieve adequate graft length and diameter. More recently, four-strand semitendinosus (ST-only) constructs have been adopted to avoid gracilis harvest and reduce donor-site morbidity when sufficient ST tendon length is available. However, to our knowledge, the intrinsic biomechanical properties of four-strand ST-only and ST + GR grafts have not been directly compared. Methods: Twenty-five hamstring allografts (17 ST, 8 GR) from a single provider were prepared into two four-strand configurations: ST-only (n = 9) and ST + GR (n = 8). Manufacturer-reported folded tendon diameters were used to estimate four-strand graft diameters. Grafts underwent preconditioning, cyclic loading (80–250 N), and load-to-failure testing using a servomechanical testing apparatus. Ultimate failure load, stiffness, cyclic elongation, and elongation at failure were recorded. Groups were compared using the Mann–Whitney U test. Results: Mean donor age was 55.8 years (range, 27–72 years). Estimated mean graft diameter was significantly greater for ST-only constructs compared with ST + GR constructs (8.88 ± 0.62 mm vs. 7.70 ± 0.38 mm; p < 0.001). ST-only constructs demonstrated greater stiffness than ST + GR constructs (458.99 ± 54.51 vs. 364.67 ± 57.18 N/mm; p = 0.007) and lower elongation at failure (5.67 ± 1.25 vs. 7.42 ± 0.86 mm; p = 0.01). Cyclic elongation (0.259 ± 0.045 vs. 0.256 ± 0.049 mm; p = 0.89) and ultimate load to failure (1689.84 ± 121.36 vs. 1626.59 ± 324.92 N; p = 0.64) did not differ between groups. Conclusions: When tested in isolation, four-strand ST-only grafts are not biomechanically inferior to ST + GR grafts and demonstrate greater stiffness and larger estimated diameter. When sufficient semitendinosus length is available, ST-only grafts represent a biomechanically viable option for ACLR without the need for gracilis harvest.