Photosensitivity to ultraviolet (UV) light affects up to ∼80% of lupus patients. Sunlight exposure can exacerbate local as well as systemic manifestations of lupus, including nephritis, by mechanisms that are poorly understood. Here, we report that acute skin exposure to UV light triggers a neutrophil-dependent injury response in the kidney characterized by upregulated expression of endothelial adhesion molecules as well as inflammatory and injury markers associated with transient proteinuria. We showed that UV light stimulates neutrophil migration not only to the skin but also to the kidney in an IL-17A–dependent manner. Using a photoactivatable lineage tracing approach, we observed that a subset of neutrophils found in the kidney had transited through UV light–exposed skin, suggesting reverse transmigration. Besides being required for the renal induction of genes encoding mediators of inflammation (vcam-1, s100A9, and Il-1b) and injury (lipocalin-2 and kim-1), neutrophils significantly contributed to the kidney type I interferon signature triggered by UV light. Together, these findings demonstrate that neutrophils mediate subclinical renal inflammation and injury following skin exposure to UV light. Of interest, patients with lupus have subpopulations of blood neutrophils and low-density granulocytes with similar phenotypes to reverse transmigrating neutrophils observed in the mice post-UV exposure, suggesting that these cells could have transmigrated from inflamed tissue, such as the skin. Significance Neutrophils are the most abundant leukocytes in circulation and the first responders to infectious and sterile inflammation, including skin exposure to ultraviolet (UV) light. We demonstrate that neutrophils not only migrate to the UV light–exposed skin but also disseminate systemically. In the kidney, neutrophils mediate inflammatory and injury responses triggered by skin exposure to UV. They had a proinflammatory phenotype: increased production of reactive oxygen species and a subpopulation of neutrophils in the kidney extravasated from UV light-exposed skin tissue. These studies demonstrate a direct link between skin inflammation by UV light and kidney injury and implicate neutrophils as pathogenic mediators, therefore providing a model by which exposure to UV light might contribute to kidney damage in lupus patients.
Optoretinography–the non-invasive, optical imaging of light-induced functional activity in the retina–stands to provide a critical biomarker for testing the safety and efficacy of new therapies as well as their rapid translation to the clinic. Optical phase change in response to light, as readily accessible in phase-resolved OCT, offers a path towards all-optical imaging of retinal function. However, typical human eye motion adversely affects phase stability. In addition, recording fast light-induced retinal events necessitates high-speed acquisition. Here, we introduce a high-speed line-scan spectral domain OCT with adaptive optics (AO), aimed at volumetric imaging and phase-resolved acquisition of retinal responses to light. By virtue of parallel acquisition of an entire retinal cross-section (B-scan) in a single high-speed camera frame, depth-resolved tomograms at speeds up to 16 kHz were achieved with high sensitivity and phase stability. To optimize spectral and spatial resolution, an anamorphic detection paradigm was introduced, enabling improved light collection efficiency and signal roll-off compared to traditional methods. The benefits in speed, resolution and sensitivity were exemplified in imaging nanometer-millisecond scale light-induced optical path length changes in cone photoreceptor outer segments. With 660 nm stimuli, individual cone responses readily segregated into three clusters, corresponding to long, middle, and short-wavelength cones. Recording such optoretinograms on spatial scales ranging from individual cones, to 100 µm-wide retinal patches offers a robust and sensitive biomarker for cone function in health and disease.
Nearsightedness (myopia) is a global health problem of staggering proportions that has driven the hunt for environmental and genetic risk factors in hopes of gaining insight into the underlying mechanism and providing new avenues of intervention. Myopia is the dominant risk factor for leading causes of blindness, including myopic maculopathy and retinal detachment. The fundamental defect in myopia—an excessively elongated eyeball—causes blurry distance vision that is correctable with lenses or surgery, but the risk of blindness remains. Haplotypes of the long-wavelength and middle-wavelength cone opsin genes (OPN1LW and OPN1MW, respectively) that exhibit profound exon-3 skipping during pre-messenger RNA splicing are associated with high myopia. Cone photoreceptors expressing these haplotypes are nearly devoid of photopigment. Conversely, cones in the same retina that express non-skipping haplotypes are relatively full of photopigment. We hypothesized that abnormal contrast signals arising from adjacent cones differing in photopigment content stimulate axial elongation, and spectacles that reduce contrast may significantly slow myopia progression. We tested for an association between spherical equivalent refraction and OPN1LW haplotype in males of European ancestry as determined by long-distance PCR and Sanger sequencing and identified OPN1LW exon 3 haplotypes that increase the risk of common myopia. We also evaluated the effects of contrast-reducing spectacles lenses on myopia progression in children. The work presented here provides new insight into the cause and prevention of myopia progression.
Line-scan OCT incorporated with adaptive optics (AO) offers high resolution, speed, and sensitivity for imaging retinal structure and function in vivo. Here, we introduce its implementation with reflective mirror-based afocal telescopes, optimized for imaging light-induced retinal activity (optoretinography) and weak retinal reflections at the cellular scale. A non-planar optical design was followed based on previous recommendations with key differences specific to a line-scan geometry. The three beam paths fundamental to an OCT system –illumination/sample, detection, and reference– were modeled in Zemax optical design software to yield theoretically diffraction-limited performance over a 2.2 deg. field-of-view and 1.5 D vergence range at the eye’s pupil. The performance for imaging retinal structure was exemplified by cellular-scale visualization of retinal ganglion cells, macrophages, foveal cones, and rods in human observers. The performance for functional imaging was exemplified by resolving the light-evoked optical changes in foveal cone photoreceptors where the spatial resolution was sufficient for cone spectral classification at an eccentricity 0.3 deg. from the foveal center. This enabled the first in vivo demonstration of reduced S-cone (short-wavelength cone) density in the human foveola, thus far observed only in ex vivo histological preparations. Together, the feasibility for high resolution imaging of retinal structure and function demonstrated here holds significant potential for basic science and translational applications.
30 March 2020 in Journal of the Optical Society of America A
The spatial and spectral topography of the cone mosaic set the limits for detection and discrimination of chromatic sinewave gratings. Here, we sought to compare the spatial characteristics of mechanisms mediating hue perception against those mediating chromatic detection in individuals with known spectral topography and with optical aberrations removed with adaptive optics. Chromatic detection sensitivity in general exceeded previous measurements and decreased monotonically for increasingly skewed cone spectral compositions. The spatial grain of hue perception was significantly coarser than chromatic detection, consistent with separate neural mechanisms for color vision operating at different spatial scales.