Byungtae Yoo

Dr. Byungtae Yoo

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
BYByungtae Yoo
Byungtae Yoo
Sang ChoiSang Choi
Sang Choi
Despite improvements in chemical safety management systems, incidents involving the release of hazardous chemicals continue to happen. In some cases, they result in the evacuation of residents. For hazardous chemical release accidents, an evacuation plan needs to be selective enough to consider both the indoor and outdoor concentrations of nearby buildings and the time in which the maximum allowable concentration may occur. In this study, a real-time risk analysis tool was developed based on the geographic information system (GIS) in order to establish the emergency response and risk communication plan for effectively assisting decision-making personnel. A selective evacuation plan was also established by a proposed assessment module considering the indoor/outdoor pollution concentration of buildings and the release duration time of chlorine gas leakage. The GIS-based simulated modules were performed based on eleven buildings of Ulsan city, located near an industrial cluster and home to a high population density. As a result of the simulated real-time risk assessment, only four buildings were affected by chlorine gas concentration according to wind direction and diffusion time. In addition, it was considered effective to establish an indoor/outdoor evacuation plan as opposed to an outdoor evacuation plan which is outside the range of the damage. Subsequently, an emergency evacuation plan was established with the concentration of a hazardous chemical according to the decision-making matrix. This study can enlighten the real-time emergency risk assessment based on GIS while effectively supporting the emergency action plans in response to the release of hazardous chemicals in clustered plants and the community.

1 December 2014 in Korean Chemical Engineering Research
Verified
Journal Article
Open access
JKJinHyung Kim
JinHyung Kim
JYJae Mo Yang
Jae Mo Yang
JYJong-Won Yong
Jong-Won Yong
BKByung Seok Ko
Byung Seok Ko
BYByungtae Yoo
Byungtae Yoo
JKJae Wook Ko
Jae Wook Ko

30 April 2015 in Journal of the Korean Society of Safety
Verified
Journal Article
Open access
BYByungtae Yoo
Byungtae Yoo
KOKeumho Oh
Keumho Oh
JBJong-Bae Baek
Jong-Bae Baek

1 June 2020 in Journal of Korean Society of Environmental Engineers
Verified
Journal Article
Open access
PDF file
ELEunbyul Lee
Eunbyul Lee
JKJonggu Kim
Jonggu Kim
BYByungtae Yoo
Byungtae Yoo
Objectives:A paper filter was prepared by pitch based activated carbon fibers to investigate the removal efficiency of toxic gas. Also, changes in pore characteristics and mechanical properties according to the ratio of the adsorbent and the binder were observed to optimize the decrease in specific surface area and micropore, which are the unique characteristics of activated carbon fibers. In addition, it is intended to establish optimized paper filter derived activated carbon fiber manufacturing conditions through evaluation of toxic gas removal characteristics.Methods:The pore characteristics of the activated carbon fiber and prepared paper were analyzed by measuring the BET specific surface area, and SEM analysis was performed on the fine surface shape. Tensile strength and air permeability were performed according to ISO 1924-2 and ASTM D737: 04, respectively. The adsorption performance of the prepared filter was evaluated as a gas removal efficiency using a gas detection tube (GV-110S).Results and Discussion:As the content of the binder increased in the paper manufacturing process, it was confirmed that the specific surface area of ​​the prepared filter decreased by up to 39.5% compared to the activated carbon fiber. It is considered that the micropores were closed because the surface of the activated carbon fiber was coated with the excessive addition of the binder. The removal efficiency showed a removal rate of 90% of ammonia, and methyl mercaptan and hydrogen sulfide showed a removal rate of about 60%. This result might be due to the difference in the physical adsorption rate according to the vapor pressure of each material.Conclusions:An activated carbon fiber-based paper filter for removing of toxic gas was prepared. It was confirmed that the mixing ratio of the adsorbent and the binder was an important process parameter for determining moldability and adsorption performance. Finally, optimum condition was selected as weight ratio condition of 8:2.