The energy consumption in the construction industry, including the building sector, accounts for about 37–40% of the total national energy consumption in Vietnam. This study aims to perform a comprehensive review of energy efficiency policies and regulations for the building sector in Vietnam and other Asian countries. For this purpose, a systematic literature review using the PRISMA method was adopted. Based on the analysis of existing institutional, regulatory, technical, financial, market, information and knowledge, and capacity gaps of building energy efficiency policies and regulations in Vietnam as well as the reference to relevant experiences of other Asian countries, the key recommendations for short-, medium-, and long-term actions towards enhancing implementation of those policies and regulations were provided. Overall, the policy implementation strategy should prioritize strengthening institutional coordination among ministries and regulatory enforcement, developing technical infrastructure necessary for future policy implementation, and improving stakeholder capacity in the short term; expanding market-based implementation mechanisms and progressively tightening performance standards in the medium term; and achieving a comprehensive transition towards net-zero energy buildings in the long term. The findings of this study could help shift the identified gaps into opportunities for enhancing the effectiveness of energy efficiency policies and regulations for the building sector in Vietnam.
1 May 2025 in Edelweiss Applied Science and Technology
When designing the air conditioning system, it is necessary to select outdoor air calculation parameters for determining the cooling and heating loads. The pair of parameters, including enthalpy I and dry temperature t of the outdoor air, are used directly in the calculation process. The article outlines the meaning of the limit lines of the cooling/heating capacity and the airflow of an air conditioning system and presents the concept of the guarantee coefficient of the pair of parameters I and t according to the theory of probability of two events occurring simultaneously. From these, computer software was built to determine the types of guarantee coefficients Kbd and outdoor air calculation parameters for designing the air conditioning system according to the number of hours m (hours/year) that unguaranteed the indoor thermal–humidity regime. The proposed calculation method has been implemented for 30 localities in Vietnam, calculated according to twelve m values, using meteorological data over the most recent 26-30 years, which will be used to update the Vietnamese Standard for Ventilation and Air Conditioning Design (TCVN 5687:2024). The comparison of the outdoor air calculation parameters built by the guarantee coefficient method and those offered by ASHRAE for Hanoi, Vietnam, has also been carried out.