Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing communities. This is mainly due to the low signal-to-noise ratio of fetal ECG and difficulties in cancellation of maternal QRS complexes, motion and electromyographic artefacts. In this paper we present an efficient unsupervised algorithm for fetal QRS complex detection from abdominal multichannel signal recordings combining ICA and maternal ECG cancelling, which outperforms each single method. The signal is first pre-processed to remove impulsive artefacts, baseline wandering and power line interference. The following steps are then applied: maternal ECG extraction through independent component analysis (ICA); maternal QRS detection; maternal ECG cancelling through weighted singular value decomposition; enhancing of fetal ECG through ICA and fetal QRS detection. We participated in the Physionet/Computing in Cardiology Challenge 2013, obtaining the top official scores of the challenge (among 53 teams of participants) of event 1 and event 2 concerning fetal heart rate and fetal interbeat intervals estimation section. The developed algorithms are released as open-source on the Physionet website.
16 July 2007 in IEEE Transactions on Biomedical Engineering
Atrial fibrillation (AF) is the most common cardiac arrhythmia and entails an increased risk of thromboembolic events. Prediction of the termination of an AF episode, based on noninvasive techniques, can benefit patients, doctors and health systems. The method described in this paper is based on two-lead surface electrocardiograms (ECGs): 1-min ECG recordings of AF episodes including N-type (not terminating within an hour after the end of the record), S-type (terminating 1 min after the end of the record) and T-type (terminating immediately after the end of the record). These records are organised into three learning sets (N, S and T) and two test sets (A and B). Starting from these ECGs, the atrial and ventricular activities were separated using beat classification and class averaged beat subtraction, followed by the evaluation of seven parameters representing atrial or ventricular activity. Stepwise discriminant analysis selected the set including dominant atrial frequency (DAF, index of atrial activity) and average HR (HRmean, index of ventricular activity) as optimal for discrimination between N/T-type episodes. The linear classifier, estimated on the 20 cases of the N and T learning sets, provided a performance of 90% on the 30 cases of a test set for the N/T-type discrimination. The same classifier led to correct classification in 89% of the 46 cases for N/S-type discrimination. The method has shown good results and seems to be suitable for clinical application, although a larger dataset would be very useful for improvement and validation of the algorithms and the development of an earlier predictor of paroxysmal AF spontaneous termination time.
Background: Essential hypertension is characterized by both increased oxidative stress and sympathetic traffic. Experimental studies have shown that reactive oxygen species can modulate autonomic activity.
1 October 2006 in Biomedical Engineering / Biomedizinische Technik
In the context of HRV analysis, we evaluated the information content of two measures that can easily be derived from the classical RR time-domain indexes. The two measures are: 1) the ratio sd/rmssd, where sd is the RR standard deviation and rmssd is the root mean square of squared differences of consecutive RR beats; and 2) the ratio sd2/sd1, where sd2 and sd1 are extracted from the Poincaré plot and represent the transversal and longitudinal dispersion of the cloud of points (RR(i),RR(i)(+1)). We compared the performance of the two measures with that of the classical LF/HF ratio in a group of healthy subjects who underwent a 70 degrees upright tilt test. The goodness of the results obtained by the two measures, the simplicity of their calculation and their applicability free from a priori assumptions on the characteristics of the data are proposed to the attention of the community involved in the HRV analysis as a possible alternative to the LF/HF ratio.