Background: Magnetic compression anastomosis (MCA) is mainly applied in the gastrointestinal and biliary tracts through a nonsurgical procedure that can create an anastomosis similar to that obtained through surgery. Magnets usually adsorb in the end-to-end direction (end-to-end anastomosis), exert a strong magnetic force and create an anastomosis according to the size of the magnets. Regular endoscopic dilation is required to prevent restenosis when the anastomotic size is small. We report a case in which MCA was successfully used to treat anastomotic stenosis of the sigmoid colon; the magnets adsorbed in the side-to-side direction rather than the end-to-end direction and generated a wide anastomosis in a short time that did not require endoscopic dilation. Case presentation: An 81-year-old woman was admitted to our hospital to treat anastomotic stenosis of the sigmoid colon for closure of transverse colostomy. Two years prior, the Hartmann operation and drainage were performed at other hospitals due to perforated diverticulitis of the sigmoid colon. Obstruction of the sigmoid colostomy occurred, and a transverse colostomy was performed. One year after the first surgery, high anterior resection was performed, but anastomotic stenosis occurred, causing obstruction. MCA was planned because the patient had a history of multiple operations and was expected to have strong adhesions postoperatively. MCA was safely performed, but two magnets were accidently adsorbed in the side-to-side direction. The magnet position could not be changed. The two magnets were expected to move and adsorb in an end-to-end direction naturally due to bowel movements. The magnets that adsorbed in the side-to-side direction dropped from the anus 5 days after treatment, and the anastomosis was observed by colonoscopy. Three ileus tubes were placed from the transverse colostomy beyond the anastomosis to prevent restenosis. Colonoscopy showed that the anastomosis diameter was wider than expected at 14 days after treatment, and endoscopic dilation was not necessary. No complications were observed in this patient’s postoperative course. Finally, closure of the patient’s colostomy was successfully performed. Conclusions: MCA with side-to-side anastomosis generated a wide anastomosis in a short time.
1 January 2019 in International Journal of Surgery Case Reports
Introduction: In laparoscopic surgery, marking of tumor location has been gaining importance. Tattoo marking has been often used but the technique carries the risk of accidental peritoneal scattering or other organ injury. We have been involved in the development of a novel fluorescent clip for marking tumor sites and supposed that its usage would reduce risks related to other marking methods. Case presentation: A 52-year-old man was diagnosed with sigmoid colon cancer and polyp, and was scheduled for laparoscopic sigmoidectomy. On the day before operation, fluorescent clips (ZEOCLIP FS: Zeon Medical co, Ltd, Tokyo) were endoscopically placed around the tumor and polyp sites, 4 clips for each lesion attached every 90 degrees within the colonic lumen, respectively. During the operation, locations of the fluorescent clips were easily confirmed using a full-color fluorescent laparoscope, VISION SENSE (Medtronic Co., U.S.). Curative operation was performed accordingly with the preoperative pathological and radiological findings. The postoperative course was uneventful. Discussion: Locations of intraluminally placed fluorescent clips were clearly and easily recognized through the serosal layer of the intestinal wall using a fluorescent laparoscope. Complications related to dye scattering or intestinal wall/other organ perforation were not observed suggesting that future incorporation of this tumor site marking technique into laparoscopic surgery might be beneficial. Conclusion: The fluorescent marking clips were easily placed and recognized with a fluorescent laparoscope. This method is expected to be safe and risks of accidental puncture related to tattoo marking method can be reduced or almost eliminated. Highlights:
Introduction: This is the first report on near-infrared fluorescent (NIRF) clip-guided gastrectomy. The NIRF clip, ZEOCLIP FS, emits NIRF signals when excited. We hypothesized that preoperative placement of the ZEOCLIP FS near a gastric lesion would allow fluorescence laparoscopic localization of the clip, and hence, the lesion, during surgery. We report this technique in two cases. Case presentation: Case 1: An 81-year-old female was diagnosed with early gastric cancer and a pedunculated 4 cm large hyperplastic polyp that had prolapsed into the duodenum, and was scheduled for laparoscopy-assisted distal gastrectomy, due to the potential risk of dissection of the polyp with the duodenal wall. On the day before surgery, ZEOCLIP FS clips were endoscopically placed at the cancer site and the polyp. The locations of the fluorescent clips were confirmed intraoperatively using a full-color fluorescence laparoscope. Case 2: An 81-year-old male was scheduled for laparoscopy-assisted total gastrectomy for gastric cancer under fluorescent clip-guidance. Clip locations could not be confirmed during initial intraoperative observation. However, when the stomach wall was raised using forceps during a second observation attempt, the fluorescent clip locations were confirmed. Discussion: In case 1, it was easy to confirm clip location, facilitating complete resection of early gastric cancer without dissecting the polyp. In case 2, the fluorescent clip was located by raising the stomach and adjusting the angle between the stomach wall and the fluorescence laparoscope. Conclusion: The positive results of these two cases warrant conducting feasibility studies for use of this method.
Background: Metastatic neuroendocrine carcinoma has an extremely poor prognosis, and no effective second-line treatment is available. Herein, we describe a case of multiple metastases after primary resection of esophageal neuroendocrine carcinoma successfully treated with nivolumab plus radiotherapy in a short time. Case presentation: A man in his 70s presented to our hospital after an abnormality was detected on an upper gastrointestinal series. Upper gastrointestinal endoscopy revealed a type 2 tumor spanning the endothelial cell junction to the abdominal esophagus. Histopathological examination of the biopsy confirmed a diagnosis of esophageal neuroendocrine carcinoma. The patient had no distant metastases. Thoracoscopic esophagectomy with three-field lymph node dissection was performed. Histopathological examination confirmed a diagnosis of esophageal neuroendocrine carcinoma with features of adenoid cystic-like carcinoma and squamoid pattern (pT2 [MP], INF a, ly1, v1 [EVG], pIM0, pDM0, pRM0, pN1 [1/28], M0; Stage II), which was positive for synaptophysin. The postoperative course was good, with no complications. The patient was treated with 100 mg of irinotecan and 100 mg of cisplatin, administered every 4 weeks, as postoperative adjuvant chemotherapy. Grade 3 loss of appetite was observed, and adjuvant chemotherapy was discontinued after four cycles of first-line treatment. A positron emission tomography–computed tomography scan 3 years after surgery showed abnormal uptake in the subaortic, left hilar, and left axillary lymph nodes, and in a mass in the right lung apex. The patient was diagnosed with metastatic esophageal neuroendocrine carcinoma postoperatively. First-line treatment could not be repeated due to toxicity from the initial treatment. Nivolumab (240 mg every 2 weeks) was administered as second-line treatment, and radiotherapy was started (56 Gy delivered in 28 fractions to the local [subaortic and hilar] lymph nodes). After 10 cycles of nivolumab in combination with radiotherapy (56 Gy), a positron emission tomography–computed tomography scan showed disappearance of all lesions. A complete response was achieved. Maintenance therapy (240 mg of nivolumab) was continued. No recurrence has been observed for 42 months. Conclusions: We experienced a case in which nivolumab in combination with radiotherapy was effective for metastatic esophageal neuroendocrine carcinoma after primary resection.
1 January 2020 in International Journal of Surgery Case Reports
Introduction: VISIONSENSE® is a new near-infrared (NIR) fluorescence laparoscope and has an NIR overlay threshold function that allows us to set a floor for the NIR signal to be included in the overlay. We report the case of a patient who underwent indocyanine green (ICG) fluorescence-guided parathyroidectomy for primary hyperparathyroidism due to parathyroid adenoma using the threshold-adjustment function of VISIONSENSE®. Presentation of case: A 40-year-old man was referred to our department for examination and treatment of hypercalcemia. ICG fluorescence-guided parathyroidectomy using VISIONSENSE® was planned on diagnosis of primary hyperparathyroidism due to parathyroid tumor. In the operation, we were unable to readily recognize the parathyroid gland (PG). After intravenous injection of ICG, fluorescence from ICG appeared from the left thyroid lobe to the PG, but PG contours remained unclear. We therefore used the threshold-adjustment function of VISIONSENSE® to discard NIR signal values <50%. Clear contours of the PG were subsequently obtained, allowing recognition of the gland and successful ICG-guided parathyroidectomy. No postoperative complications were encountered and the pathological diagnosis was parathyroid adenoma. Discussion: In our case, both PG and thyroid showed ICG fluorescence, but the intensity of thyroid fluorescence was slightly little lower than that of PG fluorescence. To differentiate between fluorescence from PG and thyroid, the threshold-adjustment function of VISIONSENSE® may prove useful. Conclusion: This case suggests that the threshold-adjustment function of VISIONSENSE® may be useful to readily identify the PG in parathyroid surgery. Highlights:
Background: Appendicectomy is generally a minimally invasive surgery, after which postoperative complications such as acute respiratory distress syndrome (ARDS) are rare. We describe a case of ARDS due to sepsis caused by Bacteroides ovatus after appendicectomy. Case presentation: A man in his 60 s presented to our hospital with a chief complaint of right lower quadrant abdominal pain. He was diagnosed with acute appendicitis and underwent emergency laparoscopic appendicectomy. Cefmetazole was administered as a perioperative antibacterial drug. Postoperatively, the abdominal findings improved. However, on postoperative day three, bloody sputum and respiratory distress were observed. We performed thoracoabdominal computed tomography (CT) and observed bilateral pleural effusion and mottled frosted glass shadows extending to both lung fields. ARDS was diagnosed. We treated the patient with steroids and sivelestat sodium and switched the antibacterial drug to meropenem. The patient’s general condition improved. After the patient was treated, Bacteroides ovatus was isolated from preoperative blood culture, which was resistant to cefmetazole. Conclusions: We encountered a case in which ARDS due to sepsis was caused by Bacteroides ovatus after acute appendicectomy. Blood culture to isolate the causative organism and determine its antimicrobial sensitivity after commencement of empiric antibiotics is important even in common diseases, such as acute appendicitis.