Bilal H. Shahine

Dr. Bilal H. Shahine

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2002 in Medical Physics
Verified
Journal Article
Closed access
EFE. Fourkal
E. Fourkal
BSBilal H. Shahine
Bilal H. Shahine
MDM. Ding
M. Ding
JLJ. S. Li
J. S. Li
TTT. Tajima
T. Tajima
CMC.‐M. Ma
C.‐M. Ma

18 February 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JLJ S Li
J S Li
BSBilal H. Shahine
Bilal H. Shahine
EFE Fourkal
E Fourkal
CMC-M Ma
C-M Ma
A particle track-repeating algorithm has been developed for proton beam dose calculation for radiotherapy. Monoenergetic protons with 250 MeV kinetic energy were simulated in an infinite water phantom using the GEANT3 Monte Carlo code. The changes in location, angle and energy for every transport step and the energy deposition along the track were recorded for the primary protons and all secondary particles. When calculating dose for a patient with a realistic proton beam, the pre-generated particle tracks were repeated in the patient geometry consisting of air, soft tissue and bone. The medium and density for each dose scoring voxel in the patient geometry were derived from patient CT data. The starting point, at which a proton track was repeated, was determined according to the incident proton energy. Thus, any protons with kinetic energy less than 250 MeV can be simulated. Based on the direction of the incident proton, the tracks were first rotated and for the subsequent steps, the scattering angles were simply repeated for air and soft tissue but adjusted properly based on the scattering power for bone. The particle step lengths were adjusted based on the density for air and soft tissue and also on the stopping powers for bone while keeping the energy deposition unchanged in each step. The difference in nuclear interactions and secondary particle generation between water and these materials was ignored. The algorithm has been validated by comparing the dose distributions in uniform water and layered heterogeneous phantoms with those calculated using the GEANT3 code for 120, 150, 180 and 250 MeV proton beams. The differences between them were within 2%. The new algorithm was about 13 times faster than the GEANT3 Monte Carlo code for a uniform phantom geometry and over 700 times faster for a heterogeneous phantom geometry.

10 March 1999 in Medical Physics
Verified
Journal Article
Closed access
BSBilal H. Shahine
Bilal H. Shahine
MAM. S. A. L. Al‐Ghazi
M. S. A. L. Al‐Ghazi
EEE. El‐Khatib
E. El‐Khatib

27 November 2018 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
AMAbbas Mkanna
Abbas Mkanna
OMOsama Mohamad
Osama Mohamad
PRPaul Ramia
Paul Ramia
RTRanim Thebian
Ranim Thebian
MMMaha Makki
Maha Makki
YZYoussef Zeidan
Youssef Zeidan
Purpose: The purpose of this study was to evaluate patient-related non-dosimetric predictors of cardiac sparing with the use of deep inspiration breath-hold (DIBH) in patients with left-sided breast cancer undergoing irradiation (RT). Materials and Methods: We retrospectively reviewed charts and treatment plans of one-hundred and three patients with left-sided breast cancer. All patients had both free-breathing (FB) and DIBH (with body surface tracking) plans available. (MHD) and V4 (heart volume receiving at least 4 Gy) were extracted from dose volume histograms. Fisher's exact and Chi-square tests were used to identify predictors of reductions in MHD and V4 after DIBH. Results: One-hundred and three patients were identified and most underwent mastectomy. MHD and V4 decreased significantly in DIBH plans (0.74 ± 0.25 Gy vs. 1.72 ± 0.98 Gy, p < 0.0001 for MHD; 4 ± 4.98 cc vs. 20.79 ± 18.2 cc, p < 0.0001 for V4). Body mass index (BMI), smoking and timing of CT simulation (spring/winter vs. summer/fall) were significant predictors of reduction in MHD whereas BMI, field size, chemotherapy, axillary dissection, and timing of CT simulation predicted reduction in V4. On multivariate analysis, BMI, and timing of CT simulation remained significant predictors of the heart-sparing effect of DIBH. Conclusions: In the setting of limited resources, identifying patients who will benefit the most from DIBH is extremely important. Prior studies have identified multiple dosimetric predictors of cardiac sparing and hereby we identified new non-dosimetric factors such as BMI and timing of treatments.

7 August 2019 in Frontiers in Oncology
Verified
Journal Article
Open access
WJWassim Jalbout
Wassim Jalbout
JZJana Abou Zahr
Jana Abou Zahr
BYBassem Youssef
Bassem Youssef
BSBilal H. Shahine
Bilal H. Shahine
Introduction: This study explores the feasibility of SRS/SRT treatment with MLC leaves wider than 2.5 mm at isocenter by inter-comparing treatment plans produced with 2.5, 5.0, and 10.0 mm leaves for various target sizes and shapes. Materials and methods: Forty previously treated patients were re-planned using 2.5, 5.0, and 10.0 mm wide MLC leaves. For each patient, all three plans were evaluated and contrasted between them in terms of five metrics: target dose homogeneity, conformity index, organs at risk dose, dose fall off outside the target, and dose to normal tissues. A regularity index RI was introduced that quantified the degree of target shape irregularity. The effect of target size and shape irregularity on feasibility of 5.0 and 10.0 mm leaves was analyzed. Results: Consistent plan degradation was observed for 10.0 mm (sometimes for 5.0 mm) compared to 2.5 mm MLC in terms of the above five plan metrics, but this degradation was small to clinically insignificant. As an exception, when target (PTV) size was smaller than about 1 cm diameter, clinically significant differences were found between 2.5, 5.0, and 10.0 mm MLC. Conclusion: 5.0 and 10.0 mm MLC can be used in SRS/SRT for targets (PTV) diameter larger than 1 cm. For smaller targets, 2.5 mm MLC is clinically superior, 5.0 is acceptable and 10.0 mm MLC is discouraged in terms of PTV dose conformity.

1 September 2017 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
HMHana Mekdash
Hana Mekdash
BSBilal H. Shahine
Bilal H. Shahine
WJWassim Jalbout
Wassim Jalbout
CCChirine Chehab
Chirine Chehab
HKHelena Abdel Khalek
Helena Abdel Khalek
BYBassem Youssef Youssef
Bassem Youssef Youssef
During total body irradiation (TBI), customized shielding blocks are positioned in front of the lungs to reduce radiation dose. The difficulty is to accurately position the blocks to cover the entire lungs. A new technique based on Computed Tomography (CT) simulation was developed to determine the exact position of lung blocks prior to treatment in order to decrease overall treatment time and reduce patient discomfort. Patients were CT simulated and lungs were contoured using a treatment planning system. Anteroposterior/posteroanterior (AP/PA) fields were designed with MLC aperture conforming to lung contours. The fields were used to represent the extent of the lungs, which was subsequently marked on the patient's skin. The lung blocks were positioned with their shadow matching the lungs' marks. Their position was radiographically verified prior to the delivery of each beam. To evaluate the efficiency of this technique, the treatment session time and the number of repeated attempts to correctly position the shielding blocks was recorded for each beam. Exact treatment times for patients treated with the old technique were not available and were hence approximated based on previous experience. We succeeded in positioning the shielding blocks from the first attempt in 10/12 beams. The position of the shielding blocks was adjusted only one time prior to treatment in 2/12 beams. These results are compared to an average of 3 attempts per beam for each patient using the conventional technique of trial and error. The average time of a treatment session was 29 min with a maximum of 41 min versus approximately 60 min in past treatments and a maximum of 120 min. This new technique succeeded in reducing the length of the overall treatment session of the conventional TBI procedure and hence reduced patient discomfort while ensuring accurate shielding of the lungs.