Choosing a suitable prosthesis to restore the functionality of the hip joint is a complex problem. The stem geometries, materials, and type of hip damage are critical factors for avoiding potential issues (aseptic loosening, fracture, and natural wear and tear). Comparing the available stems to select the best option is not straightforward because of the various loads and boundary conditions used in the tests, making the process difficult to compare the advantages and disadvantages among them. This work proposes stem assessment using a standardized base (generated from a literature review and ISO standards) to compare the stem geometries and present a new hybrid design to improve performance using the best qualities of the implants reported in the literature review. Sixteen hip prostheses were evaluated with the finite element method (FEM) using the same boundary and loading conditions through multi-objective analysis (von Mises stress and strain). Consequently, a hybrid geometry proposal was obtained by assessing specific points through the stem length (medial and lateral region) to define the cross-section (trapezoidal) and the new profile. The new hybrid implant proposal presented a stress reduction of 9.6% when compared to the reference implant P2-T (the implant with the best behavior) in the most critical activity (activity 4) using a titanium alloy. A similar stress reduction of 9.98% was obtained using ASTM F2996-13 and ISO 7206–4:2010(E) standards.
A rotor design of a Ram Air Turbine (RAT) for a commercial aircraft was created taking three sections with different airfoils along the blade; those sections were assessed to evaluate their performance at different critical velocities (41, 81 and 251 m/s) and choose the best profile configuration generating a new proposal to increase the glide ratio by reducing the drag, which is helpful in emergency cases. The Blade Element Momentum (BEM) theory and Computational Fluid Dynamics (CFD) were used to analyze an initial design, then validating these results with the open software QBlade. For the BEM theory a program was created for the design and performance of the RAT adding the Viterna methodology for airfoil analysis. 16 designs were proposed by strategically interchanging wing profiles in different blade sections. These designs were analyzed by CFD, using the complete rotor and the turbulence model. An optimal geometry was found, presenting a significant drag reduction of 25% generating an increase in the glide ratio and improving aircraft control in addition to maintaining the power generation above the desired values; therefore, it recommends using different airfoils for each section of a RAT's rotor blade.
The use of composite materials in aerospace structures has led to significant weight reductions and improved performance. However, their behavior under low-energy impact remains a critical concern due to the potential initiation of barely visible damage. This study investigates the crack initiation mechanisms in composite airfoil profiles subjected to low-energy impact, simulating real-world scenarios such as hail or bird strikes. Two types of airfoil profiles were fabricated using bidirectional carbon fiber reinforced polymer (CFRP) with epoxy resin and tested under ASTM D7136 impact conditions. Tensile tests following ASTM D3039 were conducted to assess post-impact mechanical behavior. The damage patterns were analyzed using high-resolution microscopy and non-destructive inspection techniques. Results revealed that damage severity and propagation depend on impact energy levels and airfoil geometry, with SC(2)-0714 exhibiting better impact resistance than GOE777-IL. Microscopic analysis confirmed that delamination initiated at 45° fiber orientations, expanding along interlaminar regions, while airfoil curvature influenced the impact energy dissipation.
8 February 2020 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Malunion is a common complication of distal radius fracture and often causes a reduction in the range of motion. The measurement of the range of motion is a part of the process for evaluating the final motion after a malunion of a distal radius fracture is diagnosed. However, the amount of range of motion reduced due to the malunion often is calculated upon the assumption that the motion is equal in both forearms. Although this assumption has been questioned, not much work has been conducted which defines the difference in range of motion between the two forearms. In this work, a methodology has been proposed to measure the forearm range of motion using inertial measurement units. The motion was measured in both forearms of a control group. Afterwards, the motion was compared between both forearm sides; then, differences and relationships were drawn. Our results indicated that the forearm rotational motion is larger in the dominant forearm. Moreover, pronation and supination motions differ among the limbs, supination being always larger than pronation. In the dominant forearm, supination is much larger than pronation, while in the non-dominant their magnitudes are rather close. These results provide important data for a more accurate way to determine how the malunion of a fracture or another pathology affects the forearm motion.