Yensa Rodríguez

Dr. Yensa Rodríguez

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2007 in Biomédica
Verified
Journal Article
Open access
APAdriana Pabon
Adriana Pabon
GÁGonzalo Álvarez
Gonzalo Álvarez
JSJorge Antonio Yáñez Santos
Jorge Antonio Yáñez Santos
CCCarlos Céspedes
Carlos Céspedes
YRYensa Rodríguez
Yensa Rodríguez
SBSilvia Blair
Silvia Blair
Introducción. Una de las estrategias para disminuir la morbimortalidad por paludismo es realizar un diagnóstico temprano mediante pruebas rápidas de baja complejidad técnica, altamente sensibles y específicas, que puedan ser realizadas e interpretadas por personas de la misma comunidad, garantizando un tratamiento antipalúdico adecuado y oportuno. Objetivo. Determinar la sensibilidad y especificidad de la prueba inmunocromatográfica Binax NOW® malaria ICT P.f/P.v para el diagnóstico rápido de paludismo en Turbo, Antioquia. Materiales y métodos. Se incluyeron 171 pacientes distribuidos en dos grupos: el primero "pruebas simultáneas", 118 pacientes con síndrome febril agudo compatible con paludismo a los cuales se les aplicó ICT Pf/Pv y gota gruesa simultáneamente. El segundo "pruebas secuenciales", 53 pacientes con diagnóstico positivo por gota gruesa quienes se estudiaron para diagnóstico confirmatorio y seguimiento parasitológico los días 4 y 7 con ICT. Resultados. La sensibilidad y la especificidad de la prueba Binax NOW® malaria ICT Pf/Pv para diagnosticar infecciones por Plasmodium falciparum fueron 54,2% (IC95%: 52%-53,4%) y 93,6% (IC95%: 93,1%-94,2%), respectivamente, mientras que para Plasmodium vivax fueron 80% (IC95%: 77,9%-82,1%) y 100% (IC95%: 99,5%-100%); hubo disminución de la sensibilidad hasta 21,4% para P. falciparum y 33,3% para P. vivax con parasitemias menores de 500 parásitos/ul. En cuanto al diagnóstico confirmatorio, la prueba ICT Pf/Pv presentó una sensibilidad global de 71,6% con 20,7% de falsos positivos y 5,6% de falsos negativos. En el seguimiento, ICT mostró 36% y 34% de falsos positivos para los días 4 y 7, respectivamente. Conclusiones. La prueba Binax NOW® malaria ICT Pf/Pv como prueba diagnóstica mostró una sensibilidad muy baja para infecciones por P. falciparum y su capacidad para detectar parasitemias menores de 500 parásitos/ul es mínima. Como diagnóstico confirmatorio, la prueba ICT P.f/P.v. tiene buena sensibilidad para P. falciparum. Su uso para seguimiento de los pacientes no se recomienda

2 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
OAOlatz Saenz de Argandoña
Olatz Saenz de Argandoña
YRYensa Rodríguez
Yensa Rodríguez
JZJose Pariente Zorrilla
Jose Pariente Zorrilla
FVFrancesc Vivó
Francesc Vivó
MRMaría Teresa Rodrigo-Calvo
María Teresa Rodrigo-Calvo
SMSantiago Medrano-Martorell
Santiago Medrano-Martorell
Background/Objectives: Although ultrasound-guided fine-needle aspiration biopsy with suction (FNA-S) is preferred for evaluating thyroid nodules, the capillary technique (FNA-C) is also used. However, the diagnostic performance of both techniques remains unclear. Our objective was to compare the diagnostic performance of FNA-S versus FNA-C for thyroid nodules. Methods: This retrospective, observational, exploratory, single-center pilot evaluation study was conducted at a tertiary hospital from January 2023 to June 2024. A total of 157 ultrasound-guided FNA biopsies were prospectively analyzed, comprising 71 FNA-S and 86 FNA-C procedures. Clinical, ultrasound, and cytological parameters were evaluated to compare the rates of non-diagnostic samples (Bethesda I) and the necessity for repeat punctures. Bivariate analyses and multivariate logistic regression were conducted. Results: Both techniques exhibited comparable rates of non-diagnostic samples (28.17% for FNA-S and 27.91% for FNA-C; p = 0.220) and repetition rates (38.03% for FNA-S and 43.02% for FNA-C; p = 0.637). The only factors significantly associated with sample adequacy, regardless of techniques employed, were the location and composition of the nodule. Conclusions: Ultrasound-guided FNA-S and FNA-C yield similar diagnostic performance for biopsy of thyroid nodules. The choice may depend on operator preference and nodule characteristics.

24 October 2026 in Cancers
Verified
Journal Article
Open access
PDF file
FBFlavia Bino
Flavia Bino
CPCamilo Pineda
Camilo Pineda
JZJose Pariente Zorrilla
Jose Pariente Zorrilla
SZSolanche Jasmin Santillán Zorrilla
Solanche Jasmin Santillán Zorrilla
JMJuan Andrés Mora
Juan Andrés Mora
SGSofía González-Ortiz
Sofía González-Ortiz
Purpose: Distinguishing radionecrosis (RN) from recurrent brain metastasis (rM1) remains a major challenge in the follow-up of patients treated with surgery and radiotherapy. Although advanced imaging techniques have been proposed to improve diagnostic accuracy, they are not always available in routine clinical practice and may be limited by postoperative changes and artifacts. Histopathologically validated studies in this setting remain scarce. Methods: We retrospectively evaluated 16 patients with 17 histologically confirmed lesions who underwent repeat surgery for suspected progression after the resection of brain metastases and adjuvant radiotherapy. Preoperative MRI examinations were reviewed by two neuroradiologists using a standard MRI protocol. Qualitative features included signal characteristics, T1/T2 mismatch, enhancement patterns, and the presence of the “inflammatory cloud” and “incomplete ring enhancement” signs. Quantitative analysis included lesion, edema and necrosis volumes, apparent diffusion coefficient (ADC), intratumoral susceptibility signal (ITSS) grading, and volumetric lesion quotient (vLQ). A LASSO logistic regression model with leave-one-out cross-validation and bootstrap stability analysis was used to identify the most relevant predictors. Results: Histopathology demonstrated 11 RN lesions and six recurrent metastases. The LASSO model achieved an area under the curve of 0.71 and an overall accuracy of 76% (13/17 lesions) with a sensitivity of 82% for RN and a specificity of 67% for rM1. RN lesions were characterized by significantly higher ADC values and ITSS grades and by the exclusive presence of the inflammatory cloud and incomplete ring enhancement signs. Stability analysis identified incomplete ring enhancement (49%), ITSS grade (45%), ADC values (45%), and inflammatory cloud (44%) as the most robust predictors of RN, whereas volumetric measurements showed limited independent predictive value. Conclusions: In patients with histologically confirmed post-treatment lesions, conventional MRI provided several reproducible features that aided differentiation between radionecrosis and recurrent brain metastasis. The inflammatory cloud, incomplete ring enhancement, elevated ADC values, and higher ITSS grades emerged as the most robust imaging markers of RN. While predictive multivariable models remain exploratory, these readily available MRI features may improve diagnostic confidence in routine clinical practice and warrant validation in larger multicenter cohorts.