Yiğit Dağhan Gökdel

Dr. Yiğit Dağhan Gökdel


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Engineering Structures
Verified
Journal Article
Closed access
ADAhmet U. Dilek
Ahmet U. Dilek
AOAli D. Oguz
Ali D. Oguz
FSFurkan Satis
Furkan Satis
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel
MOMuammer Ozbek
Muammer Ozbek

23 June 2009 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel
BSB Sarioglu
B Sarioglu
SMS Mutlu
S Mutlu
AYA D Yalcinkaya
A D Yalcinkaya
This paper presents the fabrication and the test results of two-axis micromachined micro-mirror steel scanners developed for display and imaging applications. The novel fabrication method uses the conventional lithography and electrochemical metal etching techniques. A single photomask is used to define the whole structure, resulting in a simple and inexpensive fabrication process. Two different devices are designed, fabricated and characterized to test the proposed methods. Both of them employ the magnetostatic actuation to generate excitation force/torque. First device (Type-A) is a gimballed cantilever one, and it is capable of an optical scanning angle of 11.7◦ and 23.2◦ in slow- and fast-scan directions, consuming a power of 42 mW and 30.6 mW, respectively. This structure has a quality factor of 287 in the slow-scan direction and a quality factor of 195 in the fast-scan one. The second device (Type-B) is a gimballed torsional one, and it has an optical scanning angle of 76◦ and 5.9◦ in slow- and fast-scan directions, consuming 37 mW and 39 mW, respectively. This structure has a quality factor of 132 in the slow-scan and 530 in the fast-scan directions, respectively. The maximum total optical scanning angles obtained for the slow- and fast-scan axes are 105◦ (gimballed torsional device, Type-B) and 42◦ (gimballed cantilever device, Type-A). (Some figures in this article are in colour only in the electronic version)

6 January 2018 in Optical Engineering
Verified
Journal Article
Closed access
JSJanset Savaş
Janset Savaş
RKRamin Khayatzadeh
Ramin Khayatzadeh
FÇFehmi Çivitçi
Fehmi Çivitçi
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel
OFOnur Ferhanoğlu
Onur Ferhanoğlu
The flagship monthly journal of SPIE, Optical Engineering (OE) publishes peer-reviewed papers reporting on research and development in all areas of optics, photonics, and imaging science and engineering.

1 September 2019 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
YGYunus Engin Gökdağ
Yunus Engin Gökdağ
FŞFırat Şansal
Fırat Şansal
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel

5 August 2010 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel
SMSenol Mutlu
Senol Mutlu
AYArda D Yalcinkaya
Arda D Yalcinkaya

6 May 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
YWYoumin Wang
Youmin Wang
YGYiğit Dağhan Gökdel
Yiğit Dağhan Gökdel
NTNicolas Triesault
Nicolas Triesault
LWLingyun Wang
Lingyun Wang
YHYu-Yen Huang
Yu-Yen Huang
XZXiaojing Zhang
Xiaojing Zhang
We present a fluorescence two-photon laser scanning microscope that uses a soft-magnetic stainless steel microscanner to generate a 2-D Lissajous scanning pattern. The wide-scanning low-voltage driven gimbaled torsional stainless steel microelectromechanical systems (MEMSs) scanner is designed and then fabricated using electrical discharge machining. This technology offers unique advantages by allowing larger mirror surface areas (4 mm \(\times5\) mm) to enhance the fluorescence collection efficiency at low incoming signal level, and providing a rapid prototyping and low-cost alternative to silicon-based MEMS devices, particularly when large displacements and large field of view are required. A maximum total optical scan angle (TOSA) of 20.6° at 112 Hz for a drive power of 200 mW is required for the slow-scan movement, whereas the fast-scan movement occurs at the resonance frequency of 1268 Hz and has a TOSA of 26.6° using a drive power of 400 mW. The soft-magnetic microscanner incorporated in the two-photon hyperspectral fluorescence microscope demonstrates its applicability in two-photon hyperspectral imaging of circulating cancer cells, stem cells, and biological tissue with extrinsic fluorophores.