Acoustic emission (AE) monitoring is widely used to characterize coal failure, but specimens with different burst tendencies cannot be distinguished reliably using a single count, energy, b-value, or fractal indicator. This study reanalyzed archived Vallen AE data from uniaxial-compression tests on five strong-burst, five weak-burst, and three specimen-matched non-burst coal specimens. Thirteen VisualAE event tables were verified against independently decoded primary-data files; hit counts were identical and cumulative-energy differences were below 1%. Vallen C and c records were identified as transmitted and received calibration pulses and were excluded consistently from the physical-AE analysis. Calibration records contributed mean energy shares of 11.1%, 4.3%, and 92.5% in the strong-, weak-, and non-burst groups, respectively. After exclusion, the top 1% of retained events contributed 96.6%, 97.9%, and 66.6% of the AE energy; mean b-values at Ht + 5 dB were 0.788, 0.793, and 1.650; and raw-energy multifractal widths were 1.933, 1.729, and 1.219. The correlation dimension depended strongly on embedding, delay, and scaling-range choices and did not show a universal late-sequence decrease. An exploratory six-component AE multi-parameter index yielded group means of 0.659, 0.798, and 0.150. The results support complementary, explicitly parameterized AE sequence descriptors, while the non-burst sample size (n = 3), absence of strict machine-AE time synchronization, and field-scale transfer requirements limit generalization.