Xiaozhe Sun

Dr. Xiaozhe Sun


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2020 in Information
Verified
Journal Article
Open access
PDF file
XSXiaozhe Sun
Xiaozhe Sun
Xingjian WangXingjian Wang
Xingjian Wang
SLSiru Lin
Siru Lin
The aviation hydraulic actuator (HA) is a key component of the flight control system in an aircraft. It is necessary to consider the occurrence of multiple faults under harsh conditions during a flight. This study designs a multi-fault diagnosis method based on the updated interacting multiple model (UIMM). The correspondence between the failure modes and the key physical parameters of HA is found by analyzing the fault mode and mechanism. The key physical parameters of HA can be estimated by employing a series of extended Kalman filters (EKF) related to the different modes of HA. The models in UIMM are updated once the fault is determined. UIMM can reduce the number of fault models and avoid combinatorial explosion in the case of multiple faults. Simulation results indicate that the multi-fault diagnosis method based on UIMM is effective for multi-fault diagnosis of electro-hydraulic servo actuation system.

28 September 2023 in IEEE Access
Verified
Journal Article
Open access
JYJianzhong Yang
Jianzhong Yang
DHDong Hou
Dong Hou
XSXiaozhe Sun
Xiaozhe Sun
JZJinpeng Zuo
Jinpeng Zuo
To solve force-fight problem of the fly-by-wire redundant electromechanical actuation system(EMAs) in an active-active mode, a force equalization control method with feedforward and feedback control is proposed. Aiming at the un-ideal stability and robust performance of force equalization controller, an optimized Fractional Order PID controller with current feedforward (FO+IF)is adopted. Aiming at the limitation of traditional parameter tuning, the controller parameters are optimized iteratively using the particle swarm optimization (PSO) algorithm. To improve the anti-interference performance of the system, a state observer for load torque is introduced into the current feedforward control. Through setting a serious force fight situation with multiple disturbances, the performance of FOPID and FO+IF on force fight and position response were compared, and the robustness of the system under the influence of sensitive parameters was analyzed by Monte Carlo method. The experimental results show that FO+IF can effectively improve the impact of static force fight and dynamic force fight on the system.

27 November 2020 in Actuators
Verified
Journal Article
Open access
PDF file
XSXiaozhe Sun
Xiaozhe Sun
Xingjian WangXingjian Wang
Xingjian Wang
ZZZhiyuan Zhou
Zhiyuan Zhou
ZZZhihan Zhou
Zhihan Zhou
The aircraft hydraulic system is very important for the actuation system and its failure has led to a number of catastrophic accidents in the past few years. The reasons for hydraulic loss can be leakage, blockage, and structural damage. Fortunately, the development of more electric aircraft (MEA) provides a new means of solving this difficult problem. This paper designs an active fault tolerant control (AFTC) method for MEA suffering from total hydraulic loss and actuation system failure. Two different kinds of scenarios are considered: leakage/blockage and vertical tail damage. With the application of the dissimilar redundant actuation system (DRAS) in MEA, a switching mechanism can be used to change the hydraulic actuation (HA) system into an electro-hydrostatic actuation (EHA) system when the whole hydraulic system fails. Taking account of the gap between HA and EHA, a degraded model is built. As for vertical tail damage, engine differential thrust control is adopted to help regain lateral-directional stability. The engine thrust dynamics are modeled and the mapping relationship between engine differential thrust and rudder deflection is formulated. Moreover, model reference control (MRC) and linear quadratic regulator (LQR) are used to design the AFTC method. Comparative simulation with the NASA generic transportation model (GTM) is carried out to prove the proposed strategy.

1 October 2008
Verified
Conference Paper
Closed access
XSXiaozhe Sun
Xiaozhe Sun
ZCZongji Chen
Zongji Chen
XQXudong Qin
Xudong Qin
Virtual prototyping is introduced and the future development trends of Virtual Prototyping for Flight Control System are summarized. For analyzing redundancy Flight Control Computer Systems (FCCS) of Boeing, Airbus series and BUAA civil aircraft scheme, a VP testing platform for FCCS of civil aircraft is proposed. This platform is based on COTS products, modular components and user interactive interface. It can produce virtual prototypes of dissimilar redundancy FCCSs of Boeing 777, Airbus A340 and BUAA civil aircraft scheme. This platform is open and expandable, supporting concurrent multidisciplinary design.

1 August 2026 in Aerospace
Verified
Journal Article
Open access
PDF file
XSXiaozhe Sun
Xiaozhe Sun
BSBowen Sun
Bowen Sun
The electric loading function of the active sidestick system introduces new safety risks, making the failure effects of the system uncertain. To clarify the failure effect characteristics of uncommanded oscillation signals in the active sidestick system, fault mechanism analysis and fault injection simulations were conducted. For the standalone active sidestick system, oscillation faults with different injection locations, waveforms, amplitudes, and frequencies were investigated, and their effects were evaluated from three aspects: surplus force, active sidestick deflection angle, and loading motor speed. The results show that oscillation faults cause the active sidestick deflection angle to oscillate, with the response amplitude depending on the fault injection location and signal characteristics. In addition, the pilot response to the fault was incorporated into the active sidestick system. The results show that the influence of pilot response on oscillation faults exhibits significant frequency dependent characteristics. When the fault frequency is lower than approximately 0.72 Hz, the additional pilot control force reduces the aircraft pitch angle tracking error and suppresses the oscillation fault. When the fault frequency is higher than 0.72 Hz, the pilot response increases the aircraft pitch angle tracking error, and its effect changes from a counteracting action to an amplifying action. Based on the standalone active sidestick system simulated by the experimental setup, a sinusoidal oscillation fault injection experiment was conducted at the torque sensor output. The variation trends observed in the experimental results were generally consistent with the corresponding simulation results, thereby providing indirect validation of the fault injection simulations.