Murilo Matias, Carlos Flores-Mir, Márcio Rodrigues de Almeida, Bruno da Silva Vieira, Karina Maria Salvatore de Freitas, Daniela Calabrese Nunes, Marcos Cezar Ferreira, Weber Ursi. Korean J Orthod 2021;51:387-96. https://doi.org/10.4041/kjod.2021.51.6.387
The aim of this study was to compare the degree of external apical root resorption (EARR) in patients treated with self-ligating Damon appliances and with conventional preadjusted appliances. The sample comprised 52 patients, divided into two groups. Group 1 consisted of 25 patients treated with self-ligating Damon appliances, with an initial age of 16.04 years, final age of 18.06 years, and treatment time of 2.02 years. Group 2 consisted of 27 patients, treated with conventional preadjusted appliances, with an initial age of 16.77 years, final age of 18.47 years and treatment time of 1.70 years. The groups were matched regarding the initial and final ages, treatment time, type of malocclusion, and treatment protocol without extractions. Root resorption was evaluated on periapical radiographs of the maxillary and mandibular incisors at the end of orthodontic treatment with the scores of Levander and Malmgren. Intergroup comparisons of root resorption were performed with Mann-Whitney tests. No significant difference in the degree of root resorption between the two groups was found. Similar degrees of resorption can be expected after non-extraction treatment with Damon self-ligating or conventional preadjusted appliances.
The aim of this study was to compare the deflection force in conventional and thermally activated nickel-titanium (NiTi) wires in passive (Damon Q) and active (Bioquick) self-ligating brackets (SLB) and in conventional brackets (CB) tied by two different methods: elastomeric ligature (EL) and metal ligature (ML). Two wire diameters (0.014 and 0.016 in.) and 10 specimens per group were used. The specimens were assembled in a clinical simulation device and tested in an Instron Universal Testing Machine, with a load cell of 10 N. For the testing procedures, the acrylic block representative of the right maxillary central incisor was palatally moved, with readings of the force at 0.5, 1, 2, and 3 mm, at a constant speed of 2 mm/min and temperature of 36.5 °C. The conventional NiTi released higher forces than the thermally activated NiTi archwires in large deflections. In general, the SLB showed lower forces, while the ML had higher forces, with both showing a similar force release behavior, constantly decreasing as the deflection decreased. The EL showed an irregular behavior. The active SLB showed smaller forces than passive, in large deflections. The SLB and the ML exhibit standard force patterns during unloading, while the elastomeric ligatures exhibit a randomly distributed force release behavior.
Coated archwires and ceramic brackets have been developed to improve facial esthetics during orthodontic treatment. However, their mechanical behavior has been shown to be different from metallic archwires and brackets. Therefore, the aim of this study was to compare the deflection forces in coated nickel-titanium (NiTi) and esthetic archwires combined with ceramic brackets.