The study aims to emphasize the clinical importance of the Deep Inspiration Breath Hold (DIBH) technique by quantifying its dosimetric advantages over Free Breathing (FB) in reducing radiation exposure to the heart, liver, and lungs for right-sided breast cancer patients. This evidence supports its potential for routine clinical use to mitigate radiation-induced toxicity. A systematic retrieval of controlled trials comparing DIBH and FB techniques in postoperative radiotherapy for right-sided breast cancer was conducted utilizing the PubMed, Embase, Cochrane Library, and Web of Science databases. The primary outcomes assessed included the doses of adjacent normal tissues (heart, liver, and lungs). Summary standardized mean differences (SMD) along with 95% confidence intervals (CI) were computed, respectively. StataMP 17 software was selected to perform data analysis. The study encompassed an analysis of 313 patients derived from seven online studies, comprising 168 individuals in the DIBH group and 269 individuals in the FB group. The findings indicated that the DIBH group received significantly lower irradiation doses to the heart, liver, and lungs in comparison to the FB group, with statistical significance (heart dose: SMD = -0.63, 95% CI -0.85 to -0.41, P < 0.05; liver dose: SMD = -1.15, 95% CI -1.91 to -0.38, P < 0.05; lung dose: SMD = -0.79, 95% CI -1.23 to -0.35, P < 0.05). This meta-analysis indicated that the application of DIBH during postoperative radiotherapy for right-sided breast cancer markedly decreases radiation exposure to the heart, liver, and lungs, while maintaining consistent tumor dose coverage. Not applicable.
Background: Monte Carlo simulation is considered as the most accurate method for dose calculation in radiotherapy. PRIMO is a Monte-Carlo program with a user-friendly graphical interface. Material and method: A VitalBeam with 6MV and 6MV flattening filter free (FFF), equipped with the 120 Millennium multileaf collimator was simulated by PRIMO. We adjusted initial energy, energy full width at half maximum (FWHM), focal spot FWHM, and beam divergence to match the measurements. The water tank and ion-chamber were used in the measurement. Percentage depth dose (PDD) and off axis ratio (OAR) were evaluated with gamma passing rates (GPRs) implemented in PRIMO. PDDs were matched at different widths of standard square fields. OARs were matched at five depths. Transmission factor and dose leaf gap (DLG) were simulated. DLG was measured by electronic portal imaging device using a sweeping gap method. Result: For the criterion of 2%/2 mm, 1%/2 mm and 1%/1 mm, the GPRs of 6MV PDD were 99.33–100%, 99–100%, and 99–100%, respectively; the GPRs of 6MV FFF PDD were 99.33–100%, 98.99–99.66%, and 97.64–98.99%, respectively; the GPRs of 6MV OAR were 96.4–100%, 90.99–100%, and 85.12–98.62%, respectively; the GPRs of 6MV FFF OAR were 95.15–100%, 89.32–100%, and 87.02–99.74%, respectively. The calculated DLG matched well with the measurement (6MV: 1.36 mm vs. 1.41 mm; 6MV FFF: 1.07 mm vs. 1.03 mm, simulation vs measurement). The transmission factors were similar (6MV: 1.25% vs. 1.32%; 6MV FFF: 0.8% vs. 1.12%, simulation vs measurement). Conclusion: The calculated PDD, OAR, DLG and transmission factor were all in good agreement with measurements. PRIMO is an independent (with respect to analytical dose calculation algorithm) and accurate Monte Carlo tool.
Brain tumors remain among the most fatal diseases of the central nervous system, and early diagnosis is vital for improving patient survival outcomes. However, conventional diagnostic approaches relying on manual interpretation of MRI scans by radiologists often suffer from subjectivity, inefficiency, and a high rate of missed diagnoses. To overcome these limitations, this study introduces a systematically optimized deep learning framework designed to achieve real-time performance while preserving high detection accuracy. Specifically, we propose the A2C2f-Mona module, which enhances local and medium-range feature perception through multi-scale depthwise convolution and residual connections; design the C2PSA-DyT module, which replaces conventional normalization layers with element-wise normalization to enhance training stability and feature distribution consistency; and introduce the CGAFusion module, which integrates high- and low-level features via a channel attention mechanism, effectively improving the detection of tumors with blurred boundaries and small volumes. Experimental evaluations demonstrate that the proposed approach surpasses YOLOv12n across all performance metrics, achieving a precision of 93.8%, recall of 88.0%, and mAP@0.5 of 94.0%. Notably, the recall for pituitary tumors shows the greatest improvement, while the recognition accuracy for gliomas is also significantly enhanced. Overall, the proposed method achieves simultaneous gains in detection accuracy and stability, underscoring its substantial potential for advancing intelligent diagnosis in medical imaging.
31 August 2023 in European Journal of Medical Research
The aim of this study was to investigate the feasibility of VMAT library-derived model transfer in the prediction of IMRT plans by dosimetry comparison among with three groups of IMRT plans: two groups of automatic IMRT plans generated by the knowledge-based the volumetric modulated arc therapy (VMAT) model and intensity-modulated radiation therapy (IMRT) model and one group of manual IMRT plans. 52 prostate cancer patients who had completed radiotherapy were selected and randomly divided into 2 groups with 40 and 12 separately. Then both VMAT and IMRT plans were manually designed for all patients. The total plans in the group with 40 cases as training datasets were added to the knowledge-based planning (KBP) models for learning and finally obtained VMAT and IMRT training models. Another 12 cases were selected as the validation group to be used to generated auto IMRT plans by KBP VMAT and IMRT models. At last, the radiotherapy plans from three groups were obtained: the automated IMRT plan (V-IMRT) predicted by the VMAT model, the automated IMRT plan (I-IMRT) predicted by the IMRT model and the manual IMRT plan (M-IMRT) designed before. The dosimetric parameters of planning target volume (PTV) and organ at risks (OARs) as well as the time parameters (monitor unit, MU) were statistically analyzed. The dose limit of all plans in the training datasets met the clinical requirements. Compared with the training plans added to VMAT model, the dosimetry parameters have no statistical differences in PTV (P > 0.05); the dose of X% volume (Dx%) with D25% and D35% in rectal and the maximum dose (Dmax) in the right femoral head were lower (P = 0.04, P = 0.01, P = 0.00) while D50% in rectal was higher (< 0.05) in the IMRT model plans. In the 12 validation cases, both automated plans showed better dose distribution compared with the M-IMRT plan: the Dmax of PTV in the I-IMRT plans and the dose in volume of interesting (VOI) of bladder and bilateral femoral heads were lower with a statistically significant difference (P < 0.05). Compared with the I-IMRT plans, dosimetric parameters in PTV and VOI of all OARs had no statistically significant differences (P > 0.05), but the Dmax in left femoral heard and D15% in the right femoral head were lower and have significant differences (P < 0.05). Furthermore, the low-dose regions, which was defined as all volumes outside of the PTV (RV) with the statistical parameters of mean dose (Dmean), the volume of covering more than 5 Gy dose (V5Gy), and also the time parameter (MU) required to perform the plan were considered. The results showed that Dmean in V-IMRT was smaller than that in the I-IMRT plan (P = 0.02) and there was no significant difference in V5Gy and MU (P > 0.05). Compared with the manual plan, the IMRT plans generated by the KBP models had a significant advantage in dose control of both OARs and PTV. Compared to the I-IMRT plans, the V-IMRT plans was not only without significant disadvantages, but it also achieved slightly better control of the low-dose region, which meet the clinical requirements and can used in the clinical treatment. This study demonstrates that it is feasible to transfer the KBP VMAT model in the prediction of IMRT plans.
Objective To investigate the comparison of MRI Enhanced T2-Fluid Attenuated Inversion Recovery(T2-FLAIR+C) sequence and Enhanced T1-Turbo Field Echo(T1-TFE+C) sequence in delineating Gross Tumor Volume (GTV) of postoperative glioma. Method Twenty patients with postoperative glioma underwent MRI simulation(MRI-sim) were enrolled. The T1-TFE+C sequence and T2-FLAIR+C sequence were separately registered with CT simulation(CT-sim). GTV was delineated by the same physician based on CT/T1 and CT/T2, respectively. Subsequently, the number, volume and overlapping ratio(OR) of GTV between the two groups were quantified and analyzed statistically. The signal intensity(SI) of the tumor area, normal gray matter and white matter (background of normal brain tissue)were measured on T1-TFE+C and T2-FLAIR+C sequences, respectively. The contrast ratio(CR) of the tumor in the two sequences were calculated and statistically analyzed. Results The volumes of GTV delineated based on CT/T1 and CT/T2 were (55.89 ± 30.20) cm3 and (56.75 ± 30.52) cm3, respectively. There was no statistically significance between the two groups of GTV volumes (P > 0.05). The maximum OR, minimum OR and average OR of GTV volumes between the two groups were 99.77%, 86.90%, and 94.51%, respectively. The CR of tumor/white matter and tumor/gray matter in T2-FLAIR+C were significantly higher than those in the T1-TFE+C sequence (P < 0.05). Conclusion The volume of GTV delineated by T2-FLAIR+C was slightly larger compared to that by T1-TFE+C, and T2-FLAIR+C could provide a more comprehensive range of GTV delineation. CR was statistically significant between the two groups (P < 0.05), and T2-FLAIR+C demonstrated the ability to accurately depict changes in tumor boundaries and surrounding edema with a higher tumor enhancement signal. Therefore, GTV delineation of gliomas based on T2-FLAIR+C may offer certain advantages and could potentially serve as a complete replacement for T1-TFE+C in future clinical applications.
Background: Breast cancer is the foremost malignancy threatening female health. This study aimed to compare the dosimetric performance of Halcyon 3.0 and TrueBeam in Volumetric Modulated Arc Therapy (VMAT) planning for breast cancer.Methods: Thirty post-operative breast cancer patients were included. VMAT plans for Halcyon 3.0 and TrueBeam were generated using 6MV FFF beams in Eclipse 16.1 with identical optimizing objectives. Organs At Risk (OARs) and target metrics were evaluated. Statistical analysis employed paired t-tests or Wilcoxon signed-rank tests (α=0.05).Results: Halcyon significantly reduced the mean dose of heart (Δ = −112.5 cGy, P< 0.001), left anterior descending artery mean dose (Δ = −151.3 cGy, P< 0.001), and spinal cord maximum dose (Δ = −88.2 cGy, P = 0.011). Low-dose exposure improved, with heart V5 (volume receiving ≥500 cGy) reduced from 22.0% to 12.6% (P< 0.001) and ipsilateral lung V5 reduced from 59.4% to 45.8% (P< 0.001) between Halcyon and TrueBeam. Halcyon lowered the absolute volume received 500 cGy by 487 cm³ (P< 0.001). Halcyon had the better target homogeneity (homogeneity index: Δ = -0.01, P< 0.001), while conformity remained comparable (P > 0.05). Despite having higher monitor units (Δ = 87.5, P< 0.001), Halcyon maintained delivery efficiency through faster leaf motion speed and gantry rotation velocity.Conclusions: Compared with TrueBeam, Halcyon achieved reduction in low-dose exposure while maintaining target coverage in breast cancer VMAT planning, thereby lowering radiation doses to OARs (e.g., heart and lung V5). This benefit is likely attributed to Halcyon’s unique staggered dual-layer MLC design.