Yangshuo Yue

Mr. Yangshuo Yue

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
YZYou Zhang
You Zhang
YPYang Pan
Yang Pan
LWLingyu Wang
Lingyu Wang
HCHaoran Cui
Haoran Cui
SJSurong Jiang
Surong Jiang
BCBai Chen
Bai Chen
Structural static testing is paramount for validating the structural integrity of critical aerospace components. However, conventional test rigs are often constrained to fixed loading axes and frequently induce parasitic torques. Accurate reproduction of aero-engine pylon flight loads therefore requires a mechanism that combines omnidirectional vector loading, high stiffness, and efficient force transmission. Achieving these coupled requirements is primarily a geometric synthesis problem, yet the associated workspace, stiffness, and load–capacity indices are nonlinear, mutually coupled, and expensive to evaluate over dense pose samples. To address this optimization bottleneck, this work develops a task-specific 6-UPS loading mechanism and a bio-inspired sensitivity-weighted NSGA-II algorithm for its geometric synthesis. Inspired by gene/locus-specific heterogeneity in biological evolution, the algorithm assigns variable-wise search intensities according to design-variable sensitivities, which are estimated using Multivariate Adaptive Regression Splines (MARS). In this way, influential design genes receive stronger local exploitation, whereas less sensitive ones retain broader exploration. Numerical simulations demonstrate that the proposed approach reduces computation time from about 30 h to 3 h relative to direct optimization with the baseline NSGA-II, while simultaneously improving workspace, stiffness, and load-carrying capacity. A hybrid physical prototype was further tested under 240 loaded pose conditions; the system maintained force magnitude errors below 0.64% (63.42 N) and directional deviations below 1.15°. These results support the efficacy of the proposed bio-inspired optimization-based design methodology for high-fidelity static testing of aero-engine pylons under the adopted hybrid setup.

6 August 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
YYYangshuo Yue
Yangshuo Yue
ZWZhao Weijie
Zhao Weijie
JWJiaxu Wang
Jiaxu Wang
ZYZelin Yu
Zelin Yu
ZZZhiheng Zha
Zhiheng Zha
XXXiaoang Xu
Xiaoang Xu
Conventional hip exoskeletons typically employ multiple actuators to provide effective assistance to the corresponding joint, leading to an increase in the weight of the exoskeleton. Underactuated designs reduce the number of actuators, thereby lowering system weight and cost. However, existing single-motor underactuated hip exoskeletons still face challenges in achieving precise assistance and accommodating non-walking movements such as free sitting. In this work, we propose an underactuated hip exoskeleton with a series elastic actuator (SEA) and two independent cables for walking assistance. The incorporation of the SEA contributes to system safety and precise assistive force control. Furthermore, the proposed differential cable structure enables free sitting movement and allows for non-strictly symmetric hip motion. In experiments, with a target assistive force of 300 N, the proposed actuator achieves a peak force-tracking accuracy of 98.01% in walking tests, and the hip exoskeleton reduces peak muscle activation by up to 23.62% during walking.