Objectives: To compare the accuracy of monitoring personal protective equipment (PPE) donning and doffing process between an artificial intelligent (AI) machine collaborated with remote human buddy support system and an onsite buddy, and to determine the degree of AI autonomy at the current development stage.Design and setting: We conducted a pilot simulation study with 30 procedural scenarios (15 donning and 15 doffing, performed by one individual) incorporating random errors in 55 steps. In total, 195 steps were assessed.Methods: The human–AI machine system and the onsite buddy assessed the procedures independently. The human–AI machine system performed the assessment via a tablet device, which was positioned to allow full-body visualization of the donning and doffing person.Results: The overall accuracy of PPE monitoring using the human–AI machine system was 100% and the overall accuracy of the onsite buddy was 99%. There was a very good agreement between the 2 methods (κ coefficient, 0.97). The current version of the AI technology was able to perform autonomously, without the remote human buddy’s rectification in 173 (89%) of 195 steps. It identified 67.3% of all the errors independently.Conclusions: This study provides preliminary evidence suggesting that a human–AI machine system may be able to serve as a substitute or enhancement to an onsite buddy performing the PPE monitoring task. It provides practical assistance using a combination of a computer mirror, visual prompts, and verbal commands. However, further studies are required to examine its clinical efficacy with a diverse range of individuals performing the donning and doffing procedures.
1 February 2016 in Diagnostic Microbiology and Infectious Disease
Data from recent conflicts related to war wounds and obligate anaerobes are limited. We define the epidemiology and antimicrobial susceptibility of obligate anaerobes from Iraq and Afghanistan casualties (6/2009-12/2013), as well as their association with clinical outcomes. Susceptibility against eleven antibiotics (7 classes) was tested. Overall, 59 patients had 119 obligate anaerobes identified (83 were first isolates). Obligate anaerobes were isolated 7-13 days post-injury, primarily from lower extremity wounds (43%), and were largely Bacteroides spp. (42%) and Clostridium spp. (19%). Patients with pelvic wounds were more likely to have Bacteroides spp. and concomitant resistant gram-negative aerobes. Seventy-three percent of isolates were resistant to ≥1 antimicrobials. Bacteroides spp. demonstrated the most resistance (16% of first isolates). Patients with resistant isolates had similar outcomes to those with susceptible strains. Serial recovery of isolates occurred in 15% of patients and was significantly associated with isolation of Bacteroides spp., along with resistant gram-negative aerobes.
The Australian and New Zealand College of Anaesthetists (ANZCA) recently reviewed and updated the guideline on equipment to manage a difficult airway. An ANZCA-established document development group, which included representatives from the Australasian College for Emergency Medicine and the College of Intensive Care Medicine of Australia and New Zealand, performed the review, which is based on expert consensus, an extensive literature review, and bi-nationwide consultation. The guideline (PG56(A) 2021, https://www.anzca.edu.au/getattachment/02fe1a4c-14f0-4ad1-8337-c281d26bfa17/PS56-Guideline-on-equipment-to-manage-difficult-airways ) is accompanied by a detailed background paper (PG56(A)BP 2021, https://www.anzca.edu.au/getattachment/9ef4cd97-2f02-47fe-a63a-9f74fa7c68ac/PG56(A)BP-Guideline-on-equipment-to-manage-difficult-airways-Background-Paper ), from which the current recommendations are reproduced on behalf of, and with the permission of, ANZCA. The updated 2021 guideline replaces the 2012 version and aims to provide an updated, objective, informed, transparent, and evidence-based review of equipment to manage difficult airways.
Due to the large number of videolaryngoscopes now available, it might be difficult for novice users to assess the various devices or use them optimally. We have collated the experiences of several airway management experts to assist in the assessment and optimal use of seven commonly used videolaryngoscopes. While all videolaryngoscopes have unique features, they can be broadly divided into those inserted via a midline approach over the tongue and those inserted laterally along the floor of the mouth. Videolaryngoscopes that are placed on the floor of the mouth displace the tongue antero-laterally and flatten the submandibular tissues. They generally require a conventional shaped bougie for tracheal intubation. Videolaryngoscopes that use the midline approach may have an in-built airway conduit for the tracheal tube or may require a ‘J-shaped’ stylet in the tracheal tube to negotiate the upper airway. This may cause difficulty when the tracheal tube is inserted through the glottis and the tip abuts the anterior wall of the subglottic space. Knowledge of the mechanism used by videolaryngoscopes to achieve laryngoscopy is essential for safe and successful tracheal intubation when using these devices.