Zhan-jun Dong

Dr. Zhan-jun Dong

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
YLYing Li
Ying Li
LMLu Meng
Lu Meng
YMYin-Ling Ma
Yin-Ling Ma
YLYajing Li
Yajing Li
XXXiaoqing Xing
Xiaoqing Xing
ZDZhan-jun Dong
Zhan-jun Dong
The third-generation epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs), osimertinib, aumolertinib, and furmonertinib represent a new treatment option for patients with EGFR p.Thr790 Met (T790 M)-mutated non-small cell lung cancer (NSCLC). Currently, there are no studies reporting the simultaneous quantification of these three drugs. A simple ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous quantitative determination of osimertinib, aumolertinib, and furmonertinib concentrations in human plasma, and it was applied for therapeutic drug monitoring (TDM). Plasma samples were processed using the protein precipitation method (acetonitrile). A positive ion monitoring mode was used for detecting analytes. D3-Sorafenib was utilized as the internal standard (IS), and the mobile phases were acetonitrile (containing 0.1% formic acid) and water with gradient elution on an XSelect HSS XP column (2.1 mm × 100.0 mm, 2.5 µm, Waters, Milford, MA, USA) at a flow rate of 0.5 mL·min−1. The method’s selectivity, precision (coefficient of variation of intra-day and inter-day ≤ 6.1%), accuracy (95.8–105.2%), matrix effect (92.3–106.0%), extraction recovery, and stability results were acceptable according to the guidelines. The linear ranges were 5–500 ng·mL−1, 2–500 ng·mL−1, and 0.5–200 ng·mL−1 for osimertinib, aumolertinib, and furmonertinib, respectively. The results show that the method was sensitive, reliable, and simple and that it could be successfully applied to simultaneously determine the osimertinib, aumolertinib, and furmonertinib blood concentrations in patients. These findings support using the method for TDM, potentially reducing the incidence of dosing blindness and adverse effects due to empirical dosing and inter-patient differences.

1 November 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
YCYanjun Cui
Yanjun Cui
YLYing Li
Ying Li
LFLiju Fan
Liju Fan
JAJing An
Jing An
XWXiaonan Wang
Xiaonan Wang
ZDZhan-jun Dong
Zhan-jun Dong

6 November 2018 in Molecules
Verified
Journal Article
Open access
PDF file
SDSongtao Dong
Songtao Dong
YLYing Li
Ying Li
HYHao-Tian Yang
Hao-Tian Yang
YWYin Wu
Yin Wu
YLYa-Jing Li
Ya-Jing Li
YZYuan Zhang
Yuan Zhang
Osimertinib, a new-generation inhibitor of the epidermal growth factor, has been used for the clinical treatment of advanced T790M mutation-positive tumors. In this research, an original analysis method was established for the quantification of osimertinib by ultra-performance liquid chromatography with time of flight mass spectrometry (UPLC-TOF-MS) in rat plasma. After protein precipitation with acetonitrile and sorafinib (internal standard, IS), they were chromatographed through a Waters XTerra MS C18 column. The mobile phase was acetonitrile and water (including 0.1% ammonia). The relative standard deviation (RSD) of the intra- and inter-day results ranged from 5.38 to 9.76% and from 6.02 to 9.46%, respectively, and the extraction recovery and matrix effects were calculated to range from 84.31 to 96.14% and from 91.46 to 97.18%, respectively. The results illustrated that the analysis method had sufficient specificity, accuracy and precision. Meanwhile, the UPLC-TOF-MS method for osimertinib was successfully applied into the pharmacokinetics of SD rats.

15 February 2022 in Molecules
Verified
Journal Article
Open access
PDF file
YCYanjun Cui
Yanjun Cui
YLYing Li
Ying Li
XLXiao Li
Xiao Li
FLFAN LIJU
FAN LIJU
XHxueru He xr he
xueru He xr he
ZDZhan-jun Dong
Zhan-jun Dong
Lenvatinib is a multi-targeted tyrosine kinase inhibitor that inhibits tumor angiogenesis, but hypertension is the most common adverse reaction. Telmisartan is an angiotensin receptor blocker used to treat hypertension. In this study, a simple ultra-performance liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of lenvatinib and telmisartan, and it was applied to the pharmacokinetic drug interaction study. Plasma samples were treated with acetonitrile to precipitate protein. Water (containing 5 mM of ammonium acetate and 0.1% formic acid) and acetonitrile (0.1% formic acid) were used as the mobile phases to separate the analytes with gradient elution using a column XSelect HSS T3 (2.1 mm × 100 mm, 2.5 μm). Multiple reaction monitoring in the positive ion mode was used for quantification. The method was validated and the precision, accuracy, matrix effect, recovery, and stability of this method were reasonable. The determination of analytes was not interfered with by other substances in the blank plasma, and the calibration curves of lenvatinib and telmisartan were linear within the range of 0.2–1000 ng/mL and 0.1–500 ng/mL, respectively. The results indicate that lenvatinib decreased the systemic exposure of telmisartan. Potential drug interactions were observed between lenvatinib and telmisartan.

25 September 2023 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
JAJing An
Jing An
LFLiju Fan
Liju Fan
XZXuran Zhi
Xuran Zhi
ZDZhan-jun Dong
Zhan-jun Dong

1 February 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
LMLu Meng
Lu Meng
YLYing Li
Ying Li
CXChaojun Xue
Chaojun Xue
CDCongyang Ding
Congyang Ding
XWXiaonan Wang
Xiaonan Wang
ZDZhan-jun Dong
Zhan-jun Dong