An ambulatory monitoring system is developed for the estimation of spatio-temporal gait parameters. The inertial measurement unit embedded in the system is composed of one biaxial accelerometer and one rate gyroscope, and it reconstructs the sagittal trajectory of a sensed point on the instep of the foot. A gait phase segmentation procedure is devised to determine temporal gait parameters, including stride time and relative stance; the procedure allows to define the time intervals needed for carrying an efficient implementation of the strapdown integration, which allows to estimate stride length, walking speed, and incline. The measurement accuracy of walking speed and inclines assessments is evaluated by experiments carried on adult healthy subjects walking on a motorized treadmill. Root-mean-square errors less than 0.18 km/h (speed) and 1.52% (incline) are obtained for tested speeds and inclines varying in the intervals [3, 6] km/h and [-5, +15]%, respectively. Based on the results of these experiments, it is concluded that foot inertial sensing is a promising tool for the reliable identification of subsequent gait cycles and the accurate assessment of walking speed and incline.
Background: Parkinson’s disease is a common and disabling pathology that is characterized by both motor and non-motor symptoms and affects millions of people worldwide. The disease significantly affects quality of life of those affected. Many works in literature discuss the effects of the disease. The most promising trends involve sensor devices, which are low cost, low power, unobtrusive, and accurate in the measurements, for monitoring and managing the pathology. Objectives: This review focuses on wearable devices for Parkinson’s disease applications and identifies five main fields: early diagnosis, tremor, body motion analysis, motor fluctuations (ON-OFF phases), and home and long-term monitoring. The concept is to obtain an overview of the pathology at each stage of development, from the beginning of the disease to consider early symptoms, during disease progression with analysis of the most common disorders, and including management of the most complicated situations (i.e. motor fluctuations and long-term remote monitoring). Data sources: The research was conducted within three databases: IEEE Xplore®, Science Direct®, and PubMed Central®, between January 2006 and December 2016. Study eligibility criteria: Since 1429 articles were found, accurate definition of the exclusion criteria and selection strategy allowed identification of the most relevant papers. Results: Finally, 136 papers were fully evaluated and included in this review, allowing a wide overview of wearable devices for the management of Parkinson's disease.
A new generation of mobile sensing approaches offers significant advantages over traditional platforms in terms of test speed, control, low cost, ease-of-operation, and data management, and requires minimal equipment and user involvement. The marriage of novel sensing technologies with cellphones enables the development of powerful lab-on-smartphone platforms for many important applications including medical diagnosis, environmental monitoring, and food safety analysis. This paper reviews the recent advancements and developments in the field of smartphone-based food diagnostic technologies, with an emphasis on custom modules to enhance smartphone sensing capabilities. These devices typically comprise multiple components such as detectors, sample processors, disposable chips, batteries and software, which are integrated with a commercial smartphone. One of the most important aspects of developing these systems is the integration of these components onto a compact and lightweight platform that requires minimal power. To date, researchers have demonstrated several promising approaches employing various sensing techniques and device configurations. We aim to provide a systematic classification according to the detection strategy, providing a critical discussion of strengths and weaknesses. We have also extended the analysis to the food scanning devices that are increasingly populating the Internet of Things (IoT) market, demonstrating how this field is indeed promising, as the research outputs are quickly capitalized on new start-up companies.
20 November 2017 in IEEE Transactions on Biomedical Engineering
Objective: The objectives of this work is to develop and test the ability of a wearable physiological sensors system, based on ECG, EDA and EEG, to capture human stress and to assess whether the detected changes in physiological signals correlate with changes in salivary cortisol level, which is a reliable, objective biomarker of stress. Methods: 15 healthy participants, seven males and six females, mean age 40.8 $\pm$ 9.5 years, wore a set of three commercial sensors to record physiological signals during the Maastricht Acute Stress Test, an experimental protocol known to elicit robust physical and mental stress in humans. Salivary samples were collected throughout the different phases of the test. Statistical analysis was performed using a Support Vector Machine (SVM) classification algorithm. A correlation analysis between extracted physiological features and salivary cortisol levels was also performed. Results: 15 features extracted from heart rate variability, electrodermal and electroencephalography signals showed a high degree of significance in disentangling stress from a relaxed state. The classification algorithm, based on significant features, provided satisfactory outcomes with 86% accuracy. Furthermore, correlation analysis showed that the observed changes in physiological features were consistent with the trend of salivary cortisol levels (R2 = 0.714). Conclusion: The tested set of wearable sensors was able to successfully capture human stress and quantify stress level. Significance: The results of this pilot study may be useful in designing portable and remote control systems, such as medical devices used to turn on interventions and prevent stress consequences.
Background: In Europe, the population of older people is increasing rapidly. Many older people prefer to remain in their homes but living alone could be a risk for their safety. In this context, robotics and other emerging technologies are increasingly proposed as potential solutions to this societal concern. However, one-third of all assistive technologies are abandoned within one year of use because the end users do not accept them. Objective: The aim of this study is to investigate the acceptance of the Robot-Era system, which provides robotic services to permit older people to remain in their homes. Methods: Six robotic services were tested by 35 older users. The experiments were conducted in three different environments: private home, condominium, and outdoor sites. The appearance questionnaire was developed to collect the users’ first impressions about the Robot-Era system, whereas the acceptance was evaluated through a questionnaire developed ad hoc for Robot-Era. Results: A total of 45 older users were recruited. The people were grouped in two samples of 35 participants, according to their availability. Participants had a positive impression of Robot-Era robots, as reflected by the mean score of 73.04 (SD 11.80) for DORO’s (domestic robot) appearance, 76.85 (SD 12.01) for CORO (condominium robot), and 75.93 (SD 11.67) for ORO (outdoor robot). Men gave ORO’s appearance an overall score higher than women (P=.02). Moreover, participants younger than 75 years understood more readily the functionalities of Robot-Era robots compared to older people (P=.007 for DORO, P=.001 for CORO, and P=.046 for ORO). For the ad hoc questionnaire, the mean overall score was higher than 80 out of 100 points for all Robot-Era services. Older persons with a high educational level gave Robot-Era services a higher score than those with a low level of education (shopping: P=.04; garbage: P=.047; reminding: P=.04; indoor walking support: P=.006; outdoor walking support: P=.03). A higher score was given by male older adults for shopping (P=.02), indoor walking support (P=.02), and outdoor walking support (P=.03). Conclusions: Based on the feedback given by the end users, the Robot-Era system has the potential to be developed as a socially acceptable and believable provider of robotic services to facilitate older people to live independently in their homes.