Hao Tian

Mr. Hao Tian

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
HTHao Tian
Hao Tian
WZWei Zhang
Wei Zhang
LXLingzhi Xie
Lingzhi Xie
YWYupeng Wu
Yupeng Wu
Yanyi SunYanyi Sun
Yanyi Sun
XWXinwen Wu
Xinwen Wu
To study Semi-Transparent photovoltaic (STPV) windows, experiments were conducted to test the energy potential of STPV window installed in buildings. Two identical rooms were built up as experimental units; one was fitted with amorphous silicon (a-silicon) photovoltaic (PV) windows, and another was fitted with a conventional window. The interactional influence was analyzed among air conditioning energy consumption, lighting energy consumption, and energy generation. It can be concluded that STPV windows could provide 0.26 kWh/per day and save 29% on comprehensive building load on a typical sunny day. In order to further investigate, buildings installed with STPV windows in four typical cities with different climate environments in southwest China were simulated and analyzed. The cooling load of the buildings were all decreased while the heating energy consumption and lighting energy consumption were lightly increased. The energy generation of STPV windows was highest in Lhasa at 402.1 kWh/year. The energy saving potential of STPV windows was predicted with good values; 54% in Kunming.

1 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
WZWei Zhang
Wei Zhang
LXLingzhi Xie
Lingzhi Xie
YWYupeng Wu
Yupeng Wu
HTHao Tian
Hao Tian
LZLin Zheng
Lin Zheng
The energy performance of the semi-transparent PV (STPV) window was carried out in a hot-summer and cold-winter zone of China. Semi-transparent PV (STPV) windows generate electric, reduce the heating load and aim to utilize daylighting efficiently. In order to analyze the energy performance of semi-transparent windows, a comparison test rig was set up which includes two test rooms of the same size. One room was installed with the STPV window and the other with a conventional window. The lighting, thermal, and electrical performance of STPV window was tested and compared with those of conventional window in the same ambient environment. It was observed that the maximum power generation of the STPV (a-SiGe) window was 33.3 W/m2 on a typical sunny day. Compared with the conventional windows, the average solar heat gain (SHGC) and Uvalue of STPV windows were 0.15 and 1.6, respectively, which is better than those of conventional window. On a sunny day, the Useful Daylighting Illuminance (UDI) of the test room was up to 52.2% better than the UDI of the conventional room. The results could support the application of photovoltaic technology in buildings in Southwest China.

28 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
HTHao Tian
Hao Tian
WZWei Zhang
Wei Zhang
LXLingzhi Xie
Lingzhi Xie
ZNZhichun Ni
Zhichun Ni
QWQingzhu Wei
Qingzhu Wei
MCMo Chen
Mo Chen
Thermal comfort is an important aspect to take into consideration for the indoor environment of a building integrated with a semi-transparent Photovoltaics (STPV) system. The thermal comfort of units with photovoltaic windows and that of conventional windows, which is an ordinary without PV, were evaluated via on-site tests and questionnaires. Using the thermal comfort investigation of the test rig, the maximum difference in air temperature was found to be around 5 °C between test unit and comparison unit. The predicted mean vote (PMV)–predicted percentage dissatisfied (PPD) value of the test unit was better than that of the comparison unit. It was observed that on sunny days, the PMV value ranged from 0.2 (nature) to 1.3 (slightly warm) in the test unit, and that of the comparison unit was 0.7 (slightly warm) to 2.0 (warm), thereby providing better thermal comfort, especially during mornings. The maximum difference in PPD values was found to reach 27% between the two units at noon. On cloudy days, the difference was negligible, and the thermal sensation between the foot and the head were almost the same. Fifty respondents were asked to complete a carefully designed questionnaire. The thermal sensation of the test unit was better than that of comparison unit, which corresponded with the test results. Thermal, lighting, acoustic, and other environment comfort scores were combined, and the acceptance of the test unit with the STPV windows was found to be 73.8%. The thermal sensation difference between men and women was around 5%. Thus, during summer, STPV windows can improve the thermal comfort and potentially reduce the air-conditioning load.

30 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
WWWei Wang
Wei Wang
LXLingzhi Xie
Lingzhi Xie
HTHao Tian
Hao Tian
MCMo Chen
Mo Chen
JLJianhui Li
Jianhui Li
PV windows can potentially produce electricity, reduce the air-conditioning load, and provide natural light. Cross-seasonal experimental tests for long period could eliminate the gap between real outdoor test and simulation estimation. In this research, the lighting-thermal-electricity performance of high-efficiency c-silicon PV windows was tested, and the improvement has been put forward according to the conditions. The long-term experiment was conducted cross different seasons, including summer, autumn, and winter seasons. The highest average power generation, 50W/m2, could be found in autumn. The average outside surface temperature of the PV window would reach 48 °C in sunny days in the autumn, which was higher than other seasons. Although the c-Si PV window maybe block the partial daylighting, the daylighting requirement still could be satisfied with the most days. Furthermore, the average Useful Daylight Illuminance was the highest in summer up to 0.79, and the average illumination uniform could be achieved at a high level in all seasons. For the improvement suggestions, some measures could be taken to reduce the indoor cooling load in summer. During winter, appropriate inner shading measures might be taken to prevent excessive illumination in the building, and allow the electricity and thermal performance of PV window.