Background: Advances in prosthetic technology, especially microprocessor-controlled knees (MPKs), have helped enhance gait symmetry and reduce fall risks for individuals who have undergone transfemoral amputation. However, challenges remain in walking in constrained situations due to the limitations of passive prosthetic feet, lacking ankle mobility. This study investigates the benefits of SYNSYS®, a new microprocessor-controlled knee–ankle–foot system (MPKA_NEW), designed to synergize knee and ankle movements. Methods: A randomized crossover trial was conducted on 12 male participants who had undergone transfemoral amputation who tested both the MPKA_NEW and their usual MPK prosthesis. Biomechanical parameters were evaluated using quantitative gait analysis in various walking conditions. Participants also completed self-reported questionnaires on their quality of life, locomotor abilities, and prosthesis satisfaction. Results: The MPKA_NEW showed a significant reduction in the risk of slipping and tripping compared to standard MPK prostheses, as evidenced by increased flat-foot time and minimum toe clearance during gait analysis. The MPKA_NEW also improved physical component scores in quality-of-life assessments (Short-Form 36 General Health Questionnaire), suggesting enhanced stability and reduced cognitive load during walking. Conclusions: The MPKA_NEW offers significant improvements in gait safety and quality of life for people who have undergone TFA, particularly in challenging conditions. Further studies are needed to assess the long-term benefits and adaptability across diverse amputee populations.
1 September 2017 in Annals of Physical and Rehabilitation Medicine
Background: Clinical evidence substantiating the advantages multi-grip myoelectric hand prosthesis over conventional myoelectric hand prosthesis in daily life remains inconclusive. Objectives: The study aimed to assess the efficacy of using a multi-grip myoelectric hand prosthesis after utilizing a conventional myoelectric hand prosthesis. Study Design: A before-and-after, multi-center, observational study included adults with complete hand amputation using a standard myoelectric hand prosthesis for more than 4 weeks. Methods: Patients were assessed at T0 with their standard myoelectric hand prosthesis, after a 4 to 6 weeks training and trial period with a multi-grip myoelectric hand prosthesis (T1) and then after an 8 to 10 weeks period of wearing (T2). The primary outcome measure was the change of upper limb function via the Orthotics and Prosthetics Users' Survey (OPUS). Results: twenty-two participants were prescribed a definitive multi-grip hand myoelectric prosthesis. On average, the duration since amputation was 6.5 ± 11.4 years. Traumatic causes accounted for 77.3% (17/22) of the cases. The upper limb function component score of the OPUS exhibited a mean increase of 6.2 ± 10.8 points (95% CI 1.5 to 11.0) from T0 to T2. Statistically significant improvements were also noted in the quality-of-life component of OPUS, the Quick DASH score, and overall satisfaction with prosthesis. Conclusions: In this study, the transition from using daily living standard myoelectric hand prosthesis to using a multi-grip myoelectric hand prosthesis yielded improvements in functionality, quality of life, and overall satisfaction (self-drafted) among individuals with complete hand amputation.
Background: Various socket designs exist, linking the residual limb together with the prosthetic components to restore the ability to walk; however, lack of socket comfort is a frequent complaint. Objective: To evaluate the impact of socket design on end-user comfort and mobility. Methods: A randomized crossover trial was set to compare comfort and mobility of above-knee amputees (AKAs) wearing an ischial containment (IC) or subischial (I-SUB) socket. Patients actively wearing IC sockets were recruited from 10 rehabilitation centers across the country. They were then fitted for an I-SUB socket by Certified Prosthetists (CPs) as an alternate socket. Participants were randomly assigned to start with one or the other socket. After a minimum of 2 weeks, each participant evaluated the Socket Comfort Score (SCS) (primary outcome) in various situations, performed the 2-min walk test, and answered the PLUS-M questionnaire (secondary outcomes). Results: A total of 25 participants were included, of whom 23 completed the study with full (n = 21) or partial data (n = 2). SCS were improved with I-SUB compared with IC in all situations, with significant differences in general, when sitting on a rigid chair, sitting in a car, and standing. The differences in self-reported mobility and walking distance at the 2-min walk test were not significant. At the end of the study, more than 80% of the participants chose to keep the I-SUB socket for their daily use. Conclusions: For the first time, this study supports that the subischial suction socket improves comfort in daily life without negatively impacting user mobility in a group of individuals with AKA.
Background/Objectives: Lower-limb amputation significantly impacts autonomy and daily functioning. Microprocessor-controlled prosthetic knees (MPKs) improve mobility, safety, and quality of life compared with non-microprocessor prosthetic knees (nMPKs). Despite general benefits, differences among MPK models remain unclear. The goal of this investigation was to evaluate functional mobility and patient-reported outcomes in active transfemoral amputees using a new MPK (PROTEOR QUATTRO) compared with existing MPKs. Methods: In this multicenter cross-over clinical trial, active transfemoral amputees were assessed using patient-specific functional scales (PSFS), standardized locomotor capacity tests (6MWT, 10mWT, HAI, SAI) and satisfaction and quality-of-life questionnaires (PEQ-A, SF-36, ESAT). Biomechanical data collection was performed during walking test, to examine gait symmetry indices. Results: The QUATTRO MPK was associated with significantly higher PSFS scores, reflecting higher self-rated ability in performing chosen daily life activities compared with patient’s current prosthesis. Standardized locomotor tests revealed comparable performance between devices. Biomechanical analyses showed similar symmetry indices for QUATTRO and other MPKs. Patient-reported outcomes showed an improvement in physical health with QUATTRO, while overall satisfaction remained similar. Conclusions: QUATTRO improved patient-perceived ability to perform meaningful daily-life activities while maintaining comparable performance on standardized locomotor tests. These results highlight the importance of patient-centered assessments in identifying functional benefits that may guide individualized prosthetic prescriptions for active transfemoral amputees.
Walking on coronally inclined (cross-slope) surfaces imposes downhill-directed gravitational impulses that must be countered by uphill-directed mediolateral (ML) ground reaction force (GRF) impulses to sustain steady-state straight-ahead walking. We investigated how transfemoral (TFPUs) and transtibial (TTPUs) prosthesis users regulate limb-specific ML GRF impulses when walking on cross-slope. Participants included 12 TFPUs (12 males), 12 TTPUs (11 males, 1 female), and 14 able-bodied controls (6 males, 8 females) who walked at a self-selected speed on an instrumented inclined walkway. The GRFs were recorded and expressed in a surface-aligned coordinate system. The uphill-directed ML GRF impulse for each limb was computed over stance, and the total uphill ML impulse per stride was compared with the theoretical downhill gravitational impulse. We further compared downhill versus uphill limb distributions across groups and examined temporal ML GRF profiles using one-dimensional statistical parametric mapping. The strategies to achieve this balance depended on amputation level and limb position. With the intact limb downhill, both TFPUs and TTPUs relied heavily on the intact limb, generating greater uphill impulse than controls, whereas the uphill prosthetic limb contributed less. With the prosthetic limb downhill, TTPUs behaved like controls, but TFPUs increased prosthetic uphill impulse during mid-stance to exceed controls. These asymmetric strategies were achieved through the modulation of average ML GRF rather than stance time, and were accompanied by wider steps. Improving prosthetic inversion-eversion compliance and residual hip abductor-adductor strength may reduce sound-side overload and enhance safety on cross-slopes.