Olusegun Ilori

Dr. Olusegun Ilori

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
SASaheed O. Ajayi
Saheed O. Ajayi
LOLukumon O. Oyedele
Lukumon O. Oyedele
OIOlusegun Ilori
Olusegun Ilori

1 November 2018 in Applied Thermal Engineering
Verified
Journal Article
Open access
OIOlusegun Ilori
Olusegun Ilori
AJArtur J. Jaworski
Artur J. Jaworski
XMXiaoan Mao
Xiaoan Mao

24 August 2025 in Energy and Buildings
Verified
Journal Article
Open access
RARasheed B. Ayoola
Rasheed B. Ayoola
OIOlusegun Ilori
Olusegun Ilori
NPNoel Perera
Noel Perera
MMMonica Mateo-Garcia
Monica Mateo-Garcia
KAKabir Akinyemi
Kabir Akinyemi
MLMike Leonard
Mike Leonard

14 November 2014
Verified
Conference Paper
Closed access
PDF file
OIOlusegun Ilori
Olusegun Ilori
XMXiaoan Mao
Xiaoan Mao
Artur JaworskiArtur Jaworski
Artur Jaworski
Thermoacoustic systems rely on conversion between thermal and acoustic (i.e. mechanical) forms of energy. The technology lends itself to various applications such as waste heat recovery to produce useful electricity or cooling power or gas liquefaction and regasification in oil and gas industry. Detailed understanding of the fluid flow processes within the internal structures of thermoacoustic systems, especially the heat exchangers, is seen as one of the ways by which the performance of next generation of thermoacoustic systems can be improved. The current study uses 2-D computational fluid dynamics (CFD) model to perform numerical investigations of thermoacoustic heat exchangers placed in an oscillatory flow induced by a standing wave. The computational domain is chosen from a thermoacoustic rig that is built for characterisation of heat exchangers for thermoacoustic applications. Validation of the present numerical approach is first established. Then the numerical analysis is extended by modifying the geometrical and operating parameters. The geometrical parameter considered is the curvature radius of the aerodynamic shapes attached to the entrance and exit of gas channels of the heat exchangers, mainly to modify the flow characteristics. Cases are run for the drive ratios (i.e. the ratio of maximum pressure amplitude to the mean pressure) ranging from 0.3–3.0%. Turbulent model as suitable for thermoacoustic analysis is selected from the literature. Results are discussed based on velocity profiles and the pressure difference obtained as functions of phase angles in the acoustic flow cycle.


7 July 2026 in Agriengineering
Verified
Journal Article
Open access
PDF file
AOADEBAYO ADEYEMI OGUNDARE
ADEBAYO ADEYEMI OGUNDARE
YAYetunde Oyebolaji Abiodun
Yetunde Oyebolaji Abiodun
OOOlaitan David Oyefeso
Olaitan David Oyefeso
SOSunday Ojolo
Sunday Ojolo
Oludolapo A OlanrewajuOludolapo A Olanrewaju
Oludolapo A Olanrewaju
Joseph Ifeolu OrisaleyeJoseph Ifeolu Orisaleye
Joseph Ifeolu Orisaleye
The elimination of toxic and synthetic binders from the manufacture of fibreboards and particleboards is important, considering environmental and health implications. The utilization of agricultural waste for the manufacture of boards is also beneficial to waste management and enhances sustainability in the manufacturing of boards. In this study, corn stover was utilized in the manufacture of binderless bioboards. The influence of production factors, or manufacturing parameters, on the physical and mechanical properties of the bioboards was investigated. The bioboards had a density between 669.9 kg/m3 and 986.4 kg/m3, and the water absorption was between 165% and 237%. The bioboards had modulus of elasticity ranging between 13.3 and 85.6 MPa, whilst the modulus of rupture varied between 0.149 and 0.835 MPa. Also, the internal bond strength of the corn stover boards varied between 0.43 and 1.17 MPa. Particle size emerged as the dominant parameter governing density, hygroscopic behaviour, and mechanical performance, indicating that fibre packing and interlocking outweighed thermal softening effects with the investigated processing parameters. Further treatment of the corn stover is required to improve the application of the boards for load-bearing and structural applications.