Jong-Man Kim

Prof. Jong-Man Kim


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2018 in Small
Verified
Journal Article
Closed access
PDF file
KKKang‐Hyun Kim
Kang‐Hyun Kim
NJNam‐Su Jang
Nam‐Su Jang
SHSung‐Hun Ha
Sung‐Hun Ha
JCJi Hwan Cho
Ji Hwan Cho
JKJong-Man Kim
Jong-Man Kim

26 March 2014 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
SWSu-Jeong Woo
Su-Jeong Woo
JKJeong-Ho Kong
Jeong-Ho Kong
DKDae-Gon Kim
Dae-Gon Kim
JKJong-Man Kim
Jong-Man Kim
A highly elastic skin-like capacitive pressure sensor array ensuring electrical and mechanical robustness based on a thin all-elastomeric platform is presented.

15 May 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
KKKang-Hyun Kim
Kang-Hyun Kim
SHSoon Kyu Hong
Soon Kyu Hong
NJNam-Su Jang
Nam-Su Jang
SHSung-Hun Ha
Sung-Hun Ha
HLHyung Woo Lee
Hyung Woo Lee
JKJong-Man Kim
Jong-Man Kim

1 June 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
NJNam-Su Jang
Nam-Su Jang
KKKang-Hyun Kim
Kang-Hyun Kim
SHSung-Hun Ha
Sung-Hun Ha
SJSoo-Ho Jung
Soo-Ho Jung
HLHye Moon Lee
Hye Moon Lee
JKJong-Man Kim
Jong-Man Kim

16 July 2020 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
KKKang-Hyun Kim
Kang-Hyun Kim
SHSoon Kyu Hong
Soon Kyu Hong
SHSung-Hun Ha
Sung-Hun Ha
LLLuhe Li
Luhe Li
HLHyung Woo Lee
Hyung Woo Lee
JKJong-Man Kim
Jong-Man Kim
Conventional mechanical crack-based strain sensors have high mechanosensitivity but suffer from limited stretchability and poor linearity. Here, we present a simple yet highly efficient strategy to enhance the strain-sensing performance of metal-based crack sensors based on platinum (Pt)/superaligned carbon nanotube (SACNT) hybrid conducting films. The proposed sensor is simply fabricated by transferring dry-spun SACNT films onto elastomer substrates and then sputtering Pt films. The SACNT underneath the Pt film endows the Pt crack sensors with large stretchability (ε = 100%) and excellent linearity (R2 ≈ 0.996) while ensuring ultrahigh sensitivity (gauge factor ≈ 12 274) by modulating the cracking structure in the Pt film so that the cracked Pt parts can be bridged upon stretching even at high strains. In addition, the sensor response is found to be quite fast (≈257.7 ms) and stable even under long-term operation (2000 cycles at 50% strain). Based on their excellent strain-sensing performance and mechanical flexibility, the sensors are demonstrated to detect a wide range of human motions in real time. Moreover, two single sensors can be successfully assembled in a cross shape to detect complex multiaxial strains.

26 January 2018 in Nanoscale
Verified
Journal Article
Closed access
PDF file
SHSun-Hyung Ha
Sun-Hyung Ha
SHSung-Hun Ha
Sung-Hun Ha
MJMun-Bae Jeon
Mun-Bae Jeon
JCJi Hwan Cho
Ji Hwan Cho
JKJong-Man Kim
Jong-Man Kim
Highly stretchable strain sensors that are capable of collecting complex multi-axial, multidimensional strain information in real time are crucial in practical applications for human motion detection. Here we present a highly sensitive and selective multidimensional resistive strain sensor based on a monolithic integration of a stiffness-variant stretchable substrate and sensing film comprising a cross-shaped silver nanowire percolation network in a single device. The multidimensional strain sensor efficiently distinguishes strains in various directions with a large gauge factor (GF) of >20 and a wide strain-detectable range of up to 60%. The sensor also features a maximum difference in GF between the x- and y-axes of >20 and long-term performance stability for up to 500 strain cycles. The practicality of the sensor as a human motion detector is demonstrated by attaching it directly to a part of the human body and measuring the multidimensional strains that occur during motions in real time.