Sang-Ho Suh

Prof. Dr. Sang-Ho Suh

Soongsil University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
HKHyoung-Ho Kim
Hyoung-Ho Kim
MD RAKIBUZZAMANMD RAKIBUZZAMAN
MD RAKIBUZZAMAN
KKKyungwuk Kim
Kyungwuk Kim
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh
The Kaplan turbine is an axial propeller-type turbine that can simultaneously control guide vanes and runner blades, thus allowing its application in a wide range of operations. Here, turbine tip clearance plays a crucial role in turbine design and operation as high tip clearance flow can lead to a change in the flow pattern, resulting in a loss of efficiency and finally the breakdown of hydro turbines. This research investigates tip clearance flow characteristics and undertakes a transient fast Fourier transform (FFT) analysis of a Kaplan turbine. In this study, the computational fluid dynamics method was used to investigate the Kaplan turbine performance with tip clearance gaps at different operating conditions. Numerical performance was verified with experimental results. In particular, a parametric study was carried out including the different geometrical parameters such as tip clearance between stationary and rotating chambers. In addition, an FFT analysis was performed by monitoring dynamic pressure fluctuation on the rotor. Here, increases in tip clearance were shown to occur with decreases in efficiency owing to unsteady flow. With this study’s focus on analyzing the flow of the tip clearance and its effect on turbine performance as well as hydraulic efficiency, it aims to improve the understanding on the flow field in a Kaplan turbine.

7 March 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
MD RAKIBUZZAMANMD RAKIBUZZAMAN
MD RAKIBUZZAMAN
HKHyoung-Ho Kim
Hyoung-Ho Kim
KKKyungwuk Kim
Kyungwuk Kim
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh
KKKyung Yup Kim
Kyung Yup Kim
Effective hydraulic turbine design prevents sediment and cavitation erosion from impacting the performance and reliability of the machine. Using computational fluid dynamics (CFD) techniques, this study investigated the performance characteristics of sediment and cavitation erosion on a hydraulic Francis turbine by ANSYS-CFX software. For the erosion rate calculation, the particle trajectory Tabakoff–Grant erosion model was used. To predict the cavitation characteristics, the study’s source term for interphase mass transfer was the Rayleigh–Plesset cavitation model. The experimental data acquired by this study were used to validate the existing evaluations of the Francis turbine. Hydraulic results revealed that the maximum difference was only 0.958% compared with the CFD data, and 0.547% compared with the experiment (Korea Institute of Machinery and Materials (KIMM)). The turbine blade region was affected by the erosion rate at the trailing edge because of their high velocity. Furthermore, in the cavitation–erosion simulation, it was observed that abrasion propagation began from the pressure side of the leading edge and continued along to the trailing edge of the runner. Additionally, as sediment flow rates grew within the area of the attached cavitation, they increased from the trailing edge at the suction side, and efficiency was reduced. Cavitation–sand erosion results then revealed a higher erosion rate than of those of the sand erosion condition.

1 March 2018 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
RARakibuzzaman
Rakibuzzaman
KKKyungwuk Kim
Kyungwuk Kim
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh

30 January 2021 in Processes
Verified
Journal Article
Open access
PDF file
MD RAKIBUZZAMANMD RAKIBUZZAMAN
MD RAKIBUZZAMAN
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh
HKHyoung-Ho Kim
Hyoung-Ho Kim
YRYoungtae Ryu
Youngtae Ryu
KKKyung Yup Kim
Kyung Yup Kim
Discharge water from fish farms is a clean, renewable, and abundant energy source that has been used to obtain renewable energy via small hydropower plants. Small hydropower plants may be installed at offshore fish farms where suitable water is obtained throughout the year. It is necessary to meet the challenges of developing small hydropower systems, including sustainability and turbine efficiency. The main objective of this study was to investigate the possibility of constructing a small hydropower plant and develop 100 kW class propeller-type turbines in a fish farm with a permanent magnet synchronous generator (PMSG). The turbine was optimized using a computer simulation, and an experiment was conducted to obtain performance data. Simulation results were then validated with experimental results. Results revealed that streamlining the designed shape of the guide vane reduced the flow separation and improved the efficiency of the turbine. Optimizing the shape of the runner vane decreased the flow rate, reducing the water power and increasing the efficiency by about 5.57%. Also, results revealed that tubular or cross-flow turbines could be suitable for use in fish farm power plants, and the generator used should be waterproofed to avoid exposure to seawater.

10 January 2024 in Computation
Verified
Journal Article
Open access
PDF file
MD RAKIBUZZAMANMD RAKIBUZZAMAN
MD RAKIBUZZAMAN
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh
HRHyung-Woon Roh
Hyung-Woon Roh
KSKyung Hee Song
Kyung Hee Song
KSKwang Chul Song
Kwang Chul Song
Ling ZhouLing Zhou
Ling Zhou
Small submersible drainage pumps are used to discharge leaking water and rainwater in buildings. In an emergency (e.g., heavy rain or accident), advance monitoring of the flow rate is essential to enable optimal operation, considering the point where the pump operates abnormally when the water level is increased rapidly. Moreover, pump performance optimization is crucial for energy-saving policy. Therefore, it is necessary to meet the challenges of submersible pump systems, including sustainability and pump efficiency. The final goal of this study was to develop an energy-saving and highly efficient submersible drainage pump capable of performing efficiently in emergencies. In particular, this paper targeted the hydraulic performance improvement of a submersible drainage pump model. Prior to the development of driving-mode-related technology capable of emergency response, a way to improve the performance characteristics of the existing submersible drainage pump was found. Disassembling of the current pump followed by reverse engineering was performed instead of designing a new pump. Numerical simulation was performed to analyze the flow characteristics and pump efficiency. An experiment was carried out to obtain the performance, and it was validated with numerical results. The results reveal that changing the cross-sectional shape of the impeller reduced the flow separation and enhanced velocity and pressure distributions. Also, it reduced the power and increased efficiency. The results also show that the pump’s efficiency was increased to 5.56% at a discharge rate of 0.17 m3/min, and overall average efficiency was increased to 6.53%. It was concluded that the submersible pump design method is suitable for the numerical designing of an optimized pump’s impeller and casing. This paper provides insight on the design optimization of pumps.

11 November 2021
Verified
Conference Paper
Open access
PDF file
RARakibuzzaman
Rakibuzzaman
Sang-Ho SuhSang-Ho Suh
Sang-Ho Suh
IYIn-Sik Yoon
In-Sik Yoon
SJSang Yong Jung
Sang Yong Jung
The booster pump is an energy-saving system that controls the number of turns of the pump and optimal operation by installing an inverter to control the discharge pressure of the pump in accordance with the flow rate. The development of an optimum operation algorithm and flow rate information for the individual pumps without flow sensors is critical of a smart booster pump system. The objectives of this study was to investigate the algorithm based flow detection method without use of a flow sensor for each pump. Therefore, it was developed an algorithm-based flow rate detection method of individual pumps without the use of a flow sensor that has not been studied in the conventional booster pump system. The software-based processor development and experimental verification for detecting the flow rate of individual pumps were confirmed. The ensemble error was within 2%. For optimal operation, the result of examining the accumulated flow rate for the sequential operation method and the optimum operation method. The flow measurement accuracy of the system was confirmed by experiment and the development of a booster pump system without a flow sensor was found effective.