Demagnetization and eccentricity are unique and common rotor faults of permanent magnet synchronous motors, respectively. These important factors affect reliability and security of motor drive systems. Online monitoring and real-time diagnosis are typically required in highly reliable application scenarios. The influence of demagnetization and eccentricity faults on spatiotemporal distribution of stator tooth flux based on a stator magnetic flux detection device with multiple search coils is analyzed in this article by establishing a mathematical model of stator tooth flux with corresponding faults. Moreover, a method for extracting rotor fault features and formulating the corresponding fault diagnosis is proposed. Simulations and experiments showed that the proposed diagnosis method can effectively identify the corresponding fault type and diagnose the number of demagnetization poles, degree of demagnetization, and magnitude and orientation of eccentricity ratio. The proposed method can provide an important basis for the operation and maintenance of the motor, help reduce losses due to faults, and improve reliability of the motor and the entire system.
This study proposes a novel inter‐turn fault diagnosis method for a permanent magnet synchronous machine. Search coils are set on every stator tooth to measure the tooth fluxes. The high‐order harmonics produced by the inverter are adopted to diagnose the inter‐turn fault existence and locate the fault tooth. The fault severity coefficient is proposed on the basis of theoretical analysis and can identify the fault severity. A comparative analysis of a traditional method based on co‐simulation shows that the proposed method is sensitive and that the fault severity coefficient is accurate, intuitive and independent of the operating condition of the motor. An experimental platform is set up, and it validates the effectiveness of the proposed method.
Better cooling scheme is of practical significance for the research and development of Permanent Magnet Synchronous Motor (PMSM) with higher power density. In view of a surface embedded PMSM which has an outer rotor, an internal water cooling (IWC) scheme is proposed. The reasonable waterway arrangement and connection is proposed based on the slot electrical potential star graph, aiming at restraining the circulation current loss in the parallel waterways. Then the analytic formula of the eddy current loss in the copper tube is deduced by the idea of micro-element, and the position and thickness of copper tube are optimized based on the analytic formula. Finite element method (FEM) results has verified the rationality of both the proposed connection scheme and the rationality of the optimizations for the location and thickness of copper tube. The contents of this paper are of reference value for improving the PMSM power density by using IWC method.
Aiming at the torque ripple caused by significant current ripple and non‐ideal back‐electromotive force (back‐EMF) of coreless brushless DC motor (BLDCM), an incremental predictive control strategy based on unipolar pulse width modulation (PWM) is proposed in the non‐commutation interval. Firstly, the unipolar PWM scheme is used to double the current ripple frequency, which can reduce the current ripple. On this basis, the current prediction equations of adjacent control periods are subtracted to obtain the incremental current prediction equation, and the influence of non‐ideal back‐EMF on torque ripple suppression is eliminated. Finally, combined with the author's previous research on the commutation torque ripple suppression strategy, an integrated suppression strategy for non‐commutation and commutation interval is proposed. The experimental results show that, compared with the PI control strategy, the total torque ripple of the proposed strategy is reduced to less than 35%, and the current ripple is reduced. Meanwhile, the commutation time is shortened, and the advantages of coreless motor rapid response are retained. The strategy is universal, not limited by motor parameters and operating conditions, and has theoretical and engineering value.
15 July 2025 in IEEE Transactions on Instrumentation and Measurement
Effective diagnosis of inter-turn fault (ITF) is crucial for ensuring motor reliability. Existing methods using search coils (SCs) have good diagnostic and locating performance, but they require a large number of SCs and have problems of complexity and high cost. Aiming at this issue, a novel online ITF diagnosis method, which require less SCs is proposed. The proposed method analyzes the SC fluxes generated by a single stator coil and estimates the healthy SC fluxes based on the stator currents. Then, the estimated SC fluxes are compared with the measured SC fluxes to determine whether ITF exists. Furthermore, the SC fluxes corresponding to the fault in each stator coil are analyzed, and the ITF is located by comparing it with the measured SC fluxes. Simulation and experiment results have shown that the proposed method can effectively diagnose ITF and locate the specific fault coil under different operating conditions and is unaffected by other motor faults. This method can reduce the number of SCs by 67%, effectively solving the problems of complexity and high cost of the traditional SC-based diagnosis methods.