With the ever-growing integration of renewable energy sources (RESs) into the power grid to meet escalating power demand, the intermittent and volatile nature of these sources poses significant challenges to the stability of power grid. To address the unstable output power resulting from the inherent randomness and fluctuation of RES, this paper introduces a novel cooperative control strategy designed for a photovoltaic-based grid-connected system. This proposed strategy leverages both battery energy storage system (BESS) and superconducting magnetic energy storage (SMES) within the hybrid energy storage system (HESS) framework. At top-level control (TLC), the control strategy employs a fuzzy control-based low-pass filter (LPF) to dynamically regulate filtration coefficient and realize transient power allocation optimization. Simultaneously, at the underlayer level control (ULC), a fast Model Predictive Control (MPC) method is implemented to maintain DC bus voltage by one-step prediction horizon. The feasibility and superiority of the proposed control strategy are systematically validated under diverse operating conditions, demonstrating its efficacy in enhancing the stability and performance of the grid-connected system.
Given the low price and relatively high transition temperature (39 K) of MgB2 conductor, MgB2-based superconductors are a potential candidate for the lower field fusion coils, such as poloidal field (PF) coils, correction coils and feeders. However, to date, the application of MgB2 is limited to demonstrators in a low magnetic field of up to 5 T and at temperatures of up to 10 to 20 K, relying on cryogen-free, helium gas or liquid hydrogen cooling, which significantly reduce the cost of cryogenic systems. To demonstrate the feasibility and performance verification of large size MgB2 PF conductors based on ITER and CFETR requirements, a 4th-stage subsize MgB2 cable-in-conduit conductor (CICC) cable sample is made at the Institute of Plasma Physics, Chinese Academy of Sciences. The CICC contains 96 in situ MgB2 superconducting wires, manufactured by Western Superconducting Technology Ltd. and 48 copper wires. The critical current of the sub-size cables and MgB2 witness wires are examined with different background magnetic fields at 4.2 K. In addition, the AC loss is measured utilizing magnetization and calorimetric methods. To further clarify the influence of electromagnetic force on the AC loss performance, the cable sample is pressed transversely at room temperature and then inserted into a dipole magnet for AC loss measurement at 4.2 K. The critical current at 4.2 K of the subsize MgB2 CICC cable shows 20% degradation compared to the witness wires at 2 T background magnetic field. However, no further critical current degradation is visible during ramping up and down the magnetic field. The coupling loss time constant for 1 T background magnetic field amounts to 480 ms. No significant effect of the applied transverse stress on the coupling loss is observed between 0 and 10 MPa.
7 January 2022 in Superconductor Science and Technology
The inter-strand contact resistance and AC losses were measured on an International Thermonuclear Experimental Reactor (ITER) poloidal field (PF) coil joint in a parallel applied AC magnetic field. In addition, the hysteresis loss was measured as a function of the angle with the applied magnetic field on a niobium-titanium (NbTi) strand of the same type as in the joint with a vibrating sample magnetometer. The AC loss measurements were performed at four applied field conditions for combinations of 0 or 1 T offset field and 0.2 or 0.4 T sinusoidal amplitude. The hysteresis loss of the joint was compared with the measured AC loss density of the NbTi strand for the same field conditions as the joint AC loss measurement but with varying the angle of the applied field. The subsequent cable twist angles affect the hysteresis loss since the critical current and penetration field depend on the angle of the applied field. It is found that 15.5° is an effective angle for the calculation of the hysteresis loss of joint when compared to the single strand measurement. The inter-strand contact resistance measurements cover all the typical strand combinations from the five cabling stages of the individual conductors, as well as the strand combinations across the two conductors to characterize the inter-strand including the copper sole resistivity. It is the first time to measure the contact resistances and AC losses of the full-size ITER PF joint. By comparing the measured and simulated data in the JackPot-ACDC model, it is also the first time to obtain the accurate inter-strand, inter-petal and strand to copper sole contact resistivities, which are the main input parameters for the further quantitative numerical analysis of the PF joints, in any current and magnetic field conditions.
1 December 2025 in Superconductor Science and Technology
The International Thermonuclear Experimental Reactor poloidal field (PF) coils are wound into double pancakes with NbTi cable-in-conduit conductors, which are connected by joints in shaking hands lap-type configuration. The coils are operating in pulsed mode with a maximum operating current of 55 kA and peak magnetic field of 6.4 T, utilizing electromagnetic load on the conductors and joints. A series of PF qualification joint samples modified in praying hands configuration is measured in the SULTAN facility. For some samples, a nonlinear voltage-current (VI) characteristic is observed during the assessment of joint resistance. The growth of joint resistance versus the B× I product is larger than what is expected from the magneto-resistant copper contribution. Two non-homogeneous contact resistance models are developed and combined to quantitatively evaluate the reason for the nonlinear VI behavior in combination with the relevant power dissipation and current redistribution in the joint. The simulations reveal that, for the particular pre-qualification PFJEU2 sample with resistance variation up to 3.5 nΩ, the most probable reason for the nonlinear VI characteristic is a widely spread defective connection between copper sole and shim. The electromagnetic force involves a separation effect on the mechanically and electrically weakly connected parts, resulting into a varying resistance depending on transport current and background field. The hypothesis and models are validated by an experiment on a similar sample PFJEU3 and a post-mortem examination of the PFJEU2 sample.
28 July 2023 in IEEE Transactions on Applied Superconductivity
For fusion tokamaks, like ITER, the magnet systems are based on superconducting cable-in-conduit conductors (CICCs). Due to the limited production length of the CICCs and the necessary electrical and thermal connections, joints are widely used to connect the CICC units within the magnet coils, as well as the electrical and thermal interfaces outside the magnet. The joints dominate the current redistribution in the coils and thus are critical for the magnet stability. In this study, an ITER Poloidal Field (PF) coil joint operating in pulsed mode, is chosen to study the current non-uniformity and relevant stability issues. An optimized joint design by applying high resistive polyimide layers, called “masks” to actively block the large induced coupling currents, is tested with the numerical code JackPot-AC/DC. The current non-uniformity, power dissipation and thermal evolution of the joints with different configurations are quantitatively analyzed.