Incorporating wind energy on a large scale into power systems presents challenges for the operation and control of the grid. To enhance the safety of power grid operation, accurate short-term forecasting of wind power is necessary, as it minimizes the impact of randomness. Considering the uncertainty and prediction issues associated with wind power, this paper introduces a CNN–GRU ultra-short-term wind power prediction model. This model relies on multichannel signals, including data such as wind speed, wind direction, climate conditions, and historical power outputs collected from wind farms. These data types contribute to the formation of a comprehensive multichannel signal for wind power. Following that, the CNN method extracts both global and partial features from these signals. Concurrently, features are extracted from past power outputs based on their time series. These features are then combined with the ones obtained from the convolution process. Subsequently, these combined features are input into a fully connected network. This step is crucial for blending multichannel information and generating forecast results. To validate the model, it was tested using data from a wind farm located in a specific region of Sichuan Province. According to our experimental results, the model demonstrates a high level of accuracy in computation and robust generalization ability.
Emergency DC power support has become an effective frequency stability control approach. For the asynchronous power grid with multi-HVDC links, this paper proposes an optimal control based on wide-area measurements (WAMS). The prominent advantage of this control is to improve the frequency stability of the disturbed grid while taking into account the influence on power flow, node voltage and other grid frequency fluctuations. In order to evaluate the post-disturbance frequency stability, a steady-state frequency prediction model based on WAMS data is first proposed, which can reflect the correspondence between post-disturbance steady-state frequency and the DC power support amount. In order to obtain the optimal control strategy, an optimization model is established to formulate the proposed control problem. The optimization objective of the model is to minimize the frequency deviation of interconnected power grids, and the constraints are to restore steady-state frequency to target value and ensure the security of line power flow and node voltage. The final control strategy is obtained by solving the optimization model. Simulations of the modified IEEE 50-generator system are performed to validate the accuracy of the proposed frequency prediction model and the effectiveness of the proposed frequency stability control.
The isolation of the HVDC transmission system challenges the frequency stability of asynchronous power grid. Considering the high-capacity power regulation capability of multiple HVDC links, a novel frequency coordinated control method is proposed for the asynchronous interconnected power system. This method firstly establishes a detailed frequency response analysis model by using wide-area measurement data. Then, for the lowest frequency control after disturbance, based on the frequency response analysis model, the functional relationship between the lowest frequency and DC power support is deduced. Finally, considering the influence of multiple HVDC power support on node voltage, power flow of line and frequency variation of the HVDC opposite-end grids, an optimal model of frequency coordination control with minimal influence is established. By solving the model, an multiple HVDC coordinated power support scheme can be obtained to achieve the lowest frequency control target after disturbance. A typical IEEE system is improved to an asynchronous interconnected power grid for case simulation. The accuracy and effectiveness of the proposed frequency coordination control are verified by comparison with traditional method.
Ensuring the safe and stable operation of high-speed trains necessitates real-time monitoring and diagnostics of their suspension systems. While machine learning technology is widely employed for industrial equipment fault diagnosis, its effective application relies on the availability of a large dataset with annotated fault data for model training. However, in practice, the availability of informational data samples is often insufficient, with most of them being unlabeled. The challenge arises when traditional machine learning methods encounter a scarcity of training data, leading to overfitting due to limited information. To address this issue, this paper proposes a novel few-shot learning method for high-speed train fault diagnosis, incorporating sensor-perturbation injection and meta-confidence learning to improve detection accuracy. Experimental results demonstrate the superior performance of the proposed method, which introduces perturbations, compared to existing methods. The impact of perturbation effects and class numbers on fault detection is analyzed, confirming the effectiveness of our learning strategy.