The seakeeping ability of ships is one of the aspects that needs to be assessed during the design phase of ships. Traditionally, potential flow calculations and model tests are employed to investigate whether the ship performs according to specified
In this paper, capabilities of state-of-the-art computational fluid dynamics (CFD) tools in the prediction of the flow-field around a multihull catamaran advancing in straight ahead motion at nonzero drift angles are investigated. CFD estimations have been provided by three research institutes by using their in-house codes: CNR-INM using Xnavis, IIHR using CFDShip-Iowa, and CNRS/ECN using ISIS. These allowed an in-depth comparison between different methodologies, such as structured overlapping grids versus unstructured grid, different turbulence models and detached eddy simulations (DES) approaches, and level-set (LS) versus volume of fluid (VoF). The activities were pursued within the NATO AVT-183 group “reliable prediction of separated flow onset and progression for air and sea vehicles,” aimed at the assessment of CFD predictions of large three-dimensional separated flows. Comparison between estimations is provided for both integral and local quantities, and for wave-induced vortices. Validation is reported by comparison against the available experimental fluid dynamics (EFD) data. Generally, all the simulations are able to capture the main features of the flow field; grid resolution effects are dominant in the onset phase of coherent structures and turbulence model affects the dynamic of the vortices. Hydrodynamic loads are in agreement between the submissions with standard deviation of about 3.5% for the resistance prediction and about 7% for lateral force and yaw moment estimation. Wave-induced vortices are correctly captured by both LS and VoF approaches, even if some differences have been highlighted, LS showing well-defined and long life vortices.
This study investigates the local and global flow structures and mass transfer characteristics for a group of interacting side-by-side cylinders in unbounded flow. Configurations with 2, 3, 4, and 5 members are considered for a range of pitch-ratios ( ) at the Reynolds number Re =90. The focus is laid on the time-averaged and instantaneous local flow features including wake field, jet flow, vortical structures, λ2, pressure coefficient, and mass transfer coefficient as well as integral variables including hydrodynamic forces. Four flow regimes are identified based on the vortical structures and average stream-wise velocity field. At low pitch-ratio, the whole structure behaves like a single bluff body, while each member in the configuration behaves like an independent isolated bluff body when the pitch-ratio is large. Between these two regimes, asymmetrically and symmetrically deflected wake regimes are observed. Flow regimes dictate hydrodynamic and mass transfer characteristics such that a jump in the hydrodynamic forces and mass transfer coefficient is observed as the flow regime evolves from a single body to a deflected wake. The configuration's size and the position of member cylinders in the structure have more profound effects on hydrodynamic forces and mass transfer characteristics at small pitch-ratio. For all configurations, drag increases as one progresses deeper into the structure, while lift forces are always repulsive between any two neighboring cylinders. Member cylinders have comparable mass transfer coefficients at intermediate and high pitch-ratios, while exterior cylinders exhibit a higher mass transfer coefficient at low pitch-ratio. Overall, the structure's size has a more profound effect on the values of scalars at low pitch-ratios.
1 June 2023 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
All-aluminum microchannel heat exchangers have recently gained popularity in the heating, ventilation, and air conditioning industry. Despite their attractive thermal performance design, these heat exchangers make coils used in automotive, commercial, and residential applications prone to crevice corrosion. This study uses high-fidelity conjugate heat transfer simulations to model a micro channel heat exchanger system that includes fins and tubes with crossflow to compare their thermal effectiveness to gain insight into potential crevice corrosion of the MCHE alloy. This study considers three fin geometries (louver, step, and saw) with the same tube and circular shape microchannel and identifies the corrosion hot spot and thermal effectiveness. A predicted flow field also identifies crevices between fins and tube surfaces as critical corrosion hot spots often associated with low-velocity regions. The crevice volumes for the louver, step, and saw fin shapes are calculated as respectively. Results also show that the same circular microchannel louver shape fin has higher effectiveness than the step and saw shape fin. The thermal effectiveness for microchannel tubes with louver, step, and saw shape fins are 0.337, 0.20737, and 0.2895, respectively.
19 June 2023 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
In this study, high-fidelity conjugate heat transfer simulations are used to model a micro-channel heat exchanger (MCHE) in a crossflow to study its thermal-hydraulic performance. Three different microchannel geometries, namely circular, triangular, and square with louver-shaped fins, are considered. The local flow field showed a strong coupling between the microchannel flow, solid domain, and crossflow. The flow separation and wake regions formed near MCHE resulted in a large variation in the velocity field and temperature in the crossflow. The interaction of the wake region with the fins introduces significant spanwise variations, leading to variations in the thermal boundary layer. The heat conduction in the solid structure provided a non-uniform temperature field with a higher temperature near the microchannel and a slightly lower temperature near the surface exposed to the crossflow. The microchannel flow analysis showed that the internal geometry affects the pressure drop, which is highest for the triangular MCHE and lowest for the circular MCHE. Based on the effectiveness and performance index calculations, the circular MCHE exhibited the best performance, while the rectangular MCHE showed higher heat transfer effectiveness.