Leandro Teixeira

Mr. Leandro Teixeira


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in Fluids
Verified
Journal Article
Open access
PDF file
LWLuís Gustavo Macêdo West
Luís Gustavo Macêdo West
ASAndré Jackson Ramos Simões
André Jackson Ramos Simões
LTLeandro Teixeira
Leandro Teixeira
IAIgor Silva Moreira dos Anjos
Igor Silva Moreira dos Anjos
SDSamuel Bacelar de Freitas Devesa
Samuel Bacelar de Freitas Devesa
IPIuri Muniz Pepe
Iuri Muniz Pepe
Cavitation has been widely explored to enhance physical and chemical processes across various applications. This study aimed to model the key characteristics of a cavitation jet, induced by a triangular-orifice nozzle, using both experimental and numerical methods. Optical instrumentation, a pressure transducer and the Reynolds-Averaged Navier–Stokes (RANS) equations were employed. Optical instrumentation and high-speed photography detected the two-phase flow generated by water vaporization, revealing a mean decay pattern. Irradiance fluctuations and photographic evidence provided results about the light transmission dynamics through cavitating jets. Pressure fluctuations exhibited similar growth and decay, supporting optical instrumentation as a viable method for assessing cavitation intensity. Experimental data showed a strong relationship between irradiance and flow rate (R2 = 0.998). This enabled the correlation of the standard deviation of instantaneous pressure measurements and normalized flow rate (R2 = 0.977). Furthermore, vapor volume fraction and normalized flow rate reached a correlation coefficient of 0.999. On the simulation side, the SSG-RSM turbulence mode showed better agreement with experimental data, with relative deviations ranging from 2.1% to 6.6%. The numerical results suggest that vapor jet length is related to vapor fraction through a power law, enabling the development of new equations. These results demonstrated that anisotropic turbulence modeling is essential to reproduce experimental observations compared to mean flow properties. Based on the agreement between the numerical model and the experimental data for mean flow quantities, a formulation is proposed to estimate the jet length originating from the nozzle, offering a predictive approach for cavitating jet behavior.

1 April 2025 in Cuadernos de Educación y Desarrollo
Verified
Journal Article
Open access
PDF file
LSLuiz Artur dos Santos da Silva
Luiz Artur dos Santos da Silva
JGJuliane Grasiela Carvalho Gomes
Juliane Grasiela Carvalho Gomes
MSMariana Chagas Alcantara dos Santos
Mariana Chagas Alcantara dos Santos
PMPedro Guilherme Carvalho de Souza Marconi
Pedro Guilherme Carvalho de Souza Marconi
RFRafael dos Santos Figueiredo
Rafael dos Santos Figueiredo
LJLuiz Carlos Simões Soares Junior
Luiz Carlos Simões Soares Junior
A automação de processos industriais tem se tornado um elemento essencial para a otimização da produção, promovendo maior eficiência e precisão nos sistemas envolvidos. Neste contexto, o presente artigo tem como objetivo apresentar o desenvolvimento de uma bancada de processos industriais automatizada, permitindo a integração de conhecimentos multidisciplinares nas rotinas de controle e nos processos de termodinâmica e mecânica dos fluidos. A metodologia adotada envolve o desenvolvimento de um sistema que possibilita a experimentação e o aperfeiçoamento de técnicas aplicadas à automação, partindo do levantamento e análise dos requisitos técnicos para a construção da bancada. Foram utilizados processos de fabricação mecânica, sensores e ferramentas de modelagem e simulação para planejar o sistema de controle e os processos envolvidos. A bancada foi validada por meio de testes práticos, verificando a eficácia na automação dos processos e no desempenho dos sistemas de controle. Os resultados obtidos revelam que a estrutura da bancada permite a aplicação de conceitos de termodinâmica e mecânica dos fluidos, possibilitando testes e ajustes em tempo real, além de facilitar futuras expansões e adaptações conforme as necessidades de estudo e pesquisa. A experiência prática adquirida na construção e utilização desse sistema proporcionou aos participantes uma compreensão mais aprofundada dos desafios e soluções na automação de processos industriais, fortalecendo a visão multidisciplinar e tornando o aprendizado mais dinâmico e aplicável às demandas da indústria.

14 January 2026 in Fluids
Verified
Journal Article
Open access
PDF file
LWLuís Gustavo Macêdo West
Luís Gustavo Macêdo West
ASAndré Jackson Ramos Simões
André Jackson Ramos Simões
LTLeandro Teixeira
Leandro Teixeira
LOLucas Ramalho Oliveira
Lucas Ramalho Oliveira
JGJuliane Grasiela Carvalho Gomes
Juliane Grasiela Carvalho Gomes
IPIuri Muniz Pepe
Iuri Muniz Pepe
This study presents the development and validation of a high-speed optical data acquisition system for detecting and characterizing hydrodynamic cavitation downstream of a triangular nozzle. The system integrates a PIN photodiode, a transimpedance amplifier, and a high-sampling-rate microcontroller. Its performance was first evaluated using controlled sinusoidal signals, and statistical stability was assessed as a function of the number of acquired samples. Experiments were subsequently conducted in a converging–diverging conduit under biphasic flow conditions, where mean irradiance, standard deviation, and frequency spectra were analyzed downstream of the nozzle. The optical signal distributions revealed transitions in flow behavior associated with cavitation development, which were quantified through statistical metrics and spectral features. The Strouhal number was estimated from dominant frequencies extracted from the spectra, exhibiting a non-monotonic dependence on the Reynolds number, consistent with changes in flow structure and turbulence intensity. Spectral analysis further indicated frequency bands associated with energy transfer across turbulent scales and bubble dynamics. Overall, the results demonstrate that the proposed optical system constitutes a viable and non-intrusive methodology for detecting and characterizing cavitation intensity in a way that complements other optical and acoustic methods.

15 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
LSLuiz Artur dos Santos da Silva
Luiz Artur dos Santos da Silva
ASAndré Jackson Ramos Simões
André Jackson Ramos Simões
VFVitor Leao Filardi
Vitor Leao Filardi
VFVitor Ferreira
Vitor Ferreira
GDGeydison Gonzaga Demetino
Geydison Gonzaga Demetino
IPIuri Muniz Pepe
Iuri Muniz Pepe
Shell-and-tube heat exchangers often operate under harsh conditions that induce fouling, leading to loss of thermal efficiency, production downtime, and increased maintenance costs. Conventional cleaning procedures generally require scheduled or unscheduled shutdowns, with direct operational and financial impacts. In this context, ultrasonic cavitation has been investigated as a strategy for fouling prevention and equipment cleaning, with the potential to reduce cleaning downtime or support in-service mitigation strategies. This work presents the development of an acquisition platform based on a miniaturized, waterproof acoustic probe designed for operation inside 8 mm tubes under cavitating ultrasonic fields, with the goal of experimentally mapping the relative acoustic response amplitude and dominant frequency in U-tube heat exchangers. The system integrates a piezoelectric sensing element embedded in protective encapsulation, signal-conditioning electronics, and a high-sampling-rate acquisition module. Experiments were conducted in a reduced-scale exchanger comprising 90 access ports and measurement depths up to 775 mm, using 28 kHz ultrasonic transducers. The probe successfully captured both the spectral content and the spatial variation of the voltage-based acoustic response along the tube bundle, revealing position-dependent amplitude variations and dominant-frequency measurements concentrated around the imposed excitation frequency. The analysis supported the definition of a reduced set of representative sampling locations, decreasing acquisition time while preserving the main spatial trends relevant to the objectives of this study. The procedures established here provide an experimental basis for future studies on the application of ultrasound to fouling-mitigation strategies in industrial thermal systems.

1 March 2024 in Cuadernos de Educación y Desarrollo
Verified
Journal Article
Open access
PDF file
KAKimberly Nunes Araújo
Kimberly Nunes Araújo
YDYalle Oliveira Dias
Yalle Oliveira Dias
LTLeandro Teixeira
Leandro Teixeira
LPLucas Gomes Pereira
Lucas Gomes Pereira
SOSusana Carla Pires Sampaio de Oliveira
Susana Carla Pires Sampaio de Oliveira
GOGardenia Mascarenhas de Oliveira
Gardenia Mascarenhas de Oliveira
O propósito deste estudo foi avaliar nove resinas compostas de diferentes opacidades através de espectrofotometria e fluorescência, que passaram a compor os seguintes grupos (n=3): P4 (Point 4 XL1 - Kerr); M3 (Enamel Plus HRi UE3 - Micerium); BF (Filtek™ One Bulk Fill A2 - 3M); FB (Filtek™ Universal B2 - 3M ESPE); FA (Filtek™ Universal A2 - 3M); V1 (Vittra APS A2 - FGM); Z1 (Filtek™ Z350 XT A2E - 3M); Z2 (Filtek™ Z350 XT A2B - 3M); O2 (Opallis A2D - FGM). Os blocos de resina foram confeccionados e submetidos à leitura por espectrofotometria e fluorescência induzida por UV (365 nm). Os dados obtidos foram tabulados nos programas Origin 2018 (Analysis and Graphing Samples). Realizou-se o teste de diagnóstico de normalidade descritivo pelo teste Kolmogorov-Smirnov (p> 0,05) atendendo ao pré-requisito dessa distribuição, além de terem sido comparados pelo teste t de Student, com um nível de confiança de 95% (p <0,05) quando nas análises 2 a 2 e pela ANOVA e teste de Tukey, na comparação de 3 ou mais grupos. Nos resultados da análise espectrofotométrica foram constatadas diferenças significativas entre os grupos (p <0,01). As resinas avaliadas apresentaram altos índices de fluorescência na cor azul, com diferenças significativas entre os grupos (p=0,01). O grupo M3 foi considerado o mais luminoso por ter excelente reflexão e fluorescência em azul e nenhuma na cor vermelha. Resinas de esmalte cromático com altos valores de luminosidade e fluorescência possibilitam a reprodução de forma mais fidedigna das características óticas dos dentes naturais.

3 February 2025 in Cuadernos de Educación y Desarrollo
Verified
Journal Article
Open access
PDF file
SSSheila dos Santos Silva
Sheila dos Santos Silva
LTLeandro Teixeira
Leandro Teixeira
ASAndré Jackson Ramos Simões
André Jackson Ramos Simões
RNRubicely Francisco Do Nascimento
Rubicely Francisco Do Nascimento
ACAlexandre Araripe Cavalcante
Alexandre Araripe Cavalcante
GOGardenia Mascarenhas de Oliveira
Gardenia Mascarenhas de Oliveira
Para a obtenção de resultados estéticos satisfatórios é necessário a utilização de resinas compostas que apresentem propriedades óticas compatíveis com as relativas aos dentes naturais e, para tal, a escolha adequada da cor é fundamental. O propósito deste estudo foi avaliar a correlação entre as resinas compostas e a escala VITA Classical A1-D4 ® através de espectrofotometria por reflexão e transmitância da luz. Os 15 grupos (n=3) , AMT 01 (Z350, A2E); AMT 02 (Z100, A2); AMT 03 (Charisma, A2); AMT 04 (Match Class, A2E); AMT 05 ( Fill Magic, A2E); AMT 06 (Master Fill, A2); AMT 07 (Forma, A2E); AMT 08 (Vittra, A2E); O2 (Opallis, DA2); I (Vittra, Trans); FA (Filtek Universal, A); FB (Filtek Universal, B); Z1 (Z350, A2E, lote 2); VT (Match Class, A2E, lote 2) e P4 (Point 4, XL1), bem como os componentes A1, A2, A3, A3.5 e A4 da escala VITA Classical A1-D4 ® foram analisados. A espectrofotometria revelou diferenças significativas, na comparação 2 a 2, entre FA x FB, VT x Z1, O2 x I, bem como na comparação entre todos os grupos e a escala. Os valores de transmitância da luz foram maiores para resinas de esmalte e menores para resinas de dentina. Não foi encontrada uma correlação da cor entre as resinas compostas e a escala de referência, enquanto a transmitância foi compatível com a translucidez e a opacidade das resinas analisadas. A seleção da cor da resina consiste em um desafio e merece uma atenção especial na sua execução.