Luigi Montalto

Dr. Luigi Montalto

Università Politecnica delle Marche, Ancona, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2019 in The European Physical Journal A
Verified
Journal Article
Open access
PDF file
TCThe PANDA Collaboration
The PANDA Collaboration
Gianni BaruccaGianni Barucca
Gianni Barucca
FDFabrizio Davi
Fabrizio Davi
GLG. Lancioni
G. Lancioni
PMP. Mengucci
P. Mengucci
JZJ. Zmeskal
J. Zmeskal
This paper summarises a comprehensive Monte Carlo simulation study for precision resonance energy scan measurements. Apart from the proof of principle for natural width and line shape measurements of...

1 June 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
Luigi MontaltoLuigi Montalto
Luigi Montalto
Nicola PaoneNicola Paone
Nicola Paone
LSL. Scalise
L. Scalise
Daniele RinaldiDaniele Rinaldi
Daniele Rinaldi
The assessment of the stress state of scintillating crystals is an important issue for producers as well as users of such materials, because residual stress may arise during growth process. In this paper, a measurement system, based on the use of a photoelastic, conoscopic optical setup, is proposed for the assessment of stress state in scintillating crystals. Local stress values can be measured on the crystal in order to observe their spatial distribution. With the proposed system, it is possible to vary the dimensions of the inspected measurement volume. It has been validated with reference to a known stress state induced in a birefringent crystal sample and it has been tested for the case of loaded and unloaded samples, showing sub-millimetric spatial resolution and stress uncertainty ≤0.25 MPa. The proposed measurement system is a valid method for the inspection of scintillating crystals required by producers and users of such materials.

Francesco TessaroloFrancesco Tessarolo
Francesco Tessarolo
GNGiandomenico Nollo
Giandomenico Nollo
DMDevid Maniglio
Devid Maniglio
MRMarta Rigoni
Marta Rigoni
LBLuca Benedetti
Luca Benedetti
Nicola PaoneNicola Paone
Nicola Paone
The first wave of the COVID-19 pandemic brought about a broader use of masks by both professionals and the general population. This resulted in a severe worldwide shortage of devices and the need to increase import and activate production of safe and effective surgical masks at the national level. In order to support the demand for testing surgical masks in the Italian context, Universities provided their contribution by setting up laboratories for testing mask performance before releasing products into the national market. This paper reports the effort of seven Italian university laboratories who set up facilities for testing face masks during the emergency period of the COVID-19 pandemic. Measurement set-ups were built, adapting the methods specified in the EN 14683:2019+AC. Data on differential pressure (DP) and bacterial filtration efficiency (BFE) of 120 masks, including different materials and designs, were collected over three months. More than 60% of the masks satisfied requirements for DP and BFE set by the standard. Masks made of nonwoven polypropylene with at least three layers (spunbonded–meltblown–spunbonded) showed the best results, ensuring both good breathability and high filtration efficiency. The majority of the masks created with alternative materials and designs did not comply with both standard requirements, resulting in suitability only as community masks. The effective partnering between universities and industries to meet a public need in an emergency context represented a fruitful example of the so-called university “third-mission”.

26 June 2015 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
Luigi MontaltoLuigi Montalto
Luigi Montalto
Nicola PaoneNicola Paone
Nicola Paone
Daniele RinaldiDaniele Rinaldi
Daniele Rinaldi
LSLorenzo Scalise
Lorenzo Scalise
A reliable and noninvasive measurement method for the inspection of naturally birefringent transparent media is presented in this paper. It allows us to achieve a spatially resolved analysis of the stress state of birefringent materials. The developed system is based on photoelasticity and exploits a controlled laser conoscopy technique and a scanning system to perform local measurements in the volume dimensions of the media, which can be displaced over a grid of points. The configuration of the proposed laser conoscopic system is presented, and a dedicated algorithm, designed to perform digital analysis of the fringe patterns, is also described. The design and the realization of the system are discussed, as well as the advantages of the proposed system over the classic diffuse light polariscope technique. The method has been experimentally validated through laboratory tests on birefringent samples with known induced stress. The system has demonstrated its sensitivity to stress and its capability to achieve a spatial resolution on the order of 0.1 mm to resolve stress gradients (uncertainty on the stress amplitude of ±0.1  MPa).

1 October 2018 in Optical Materials
Verified
Journal Article
Closed access
ETE. Trusova
E. Trusova
AVA. Vaitkevičius
A. Vaitkevičius
YTY. Tratsiak
Y. Tratsiak
MKM. Korjik
M. Korjik
Paolo MengucciPaolo Mengucci
Paolo Mengucci
GTG. Tamulaitis
G. Tamulaitis

26 January 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PNPier Paolo Natali
Pier Paolo Natali
Luigi MontaltoLuigi Montalto
Luigi Montalto
FDFabrizio Davi
Fabrizio Davi
Paolo MengucciPaolo Mengucci
Paolo Mengucci
ACAndrea Ciriaco
Andrea Ciriaco
DRDaniele Rinaldi
Daniele Rinaldi
The tetragonal PbWO4 (PWO) is one of the most important scintillating crystals, being used both in the Compact Muon Solenoid (CMS) experiment at the European Organization for Nuclear Research (CERN) and in the PANDA project at the Facility for Antiproton and Ion Research (FAIR). Light yield and other relevant scintillation properties depend, among many factors, also on the crystal mechanical quality. Accordingly, a detailed knowledge of crystal piezo-optic properties is a mandatory step toward understanding elasto-optic behavior and performing crystal quality control. In this paper, we evaluate for the first time, to the best of our knowledge, by means of both photoelastic and x-ray measurements, some components of the piezo-optic tensor; moreover, when the crystal is acted upon by a uniaxial stress, we obtain an evaluation for the rotation angle of the optic plane under stress as well as the photoelastic constant. These parameters are necessary to detect the residual stresses within the crystal, if any, and to give an overall quality measure. Such a methodology is in general suitable for any tetragonal crystals.