Succulents encompass a wide range of species, each with unique shapes and different colors. Despite their widespread cultivation in recent years, the study of succulents lags behind that of flowers. Furthermore, there is currently no public data-set for succulent plants. As a result, we have utilized a self-built data-set and employed deep learning methods to implement succulent plant image classification. While CNN (Convolutional Neural Networks) excels at extracting local features, it requires numerous layers to capture global features, and the improvement in model performance is limited. On the other hand, the Transformer model is adept at capturing long-range dependencies in sequences due to its self-attention mechanism. However, a pure Transformer model requires a significant amount of data and parameters to surpass convolutional models. Therefore, we have focused on implementing the classification of 31 succulent plant species using the lightweight network MobileViT, which combines both convolution and Transformer. In the context of limited sample data, we have employed data augmentation and transfer learning methods to train the model for 150 epochs, achieving a test accuracy of 96.90%. Compared to other convolutional neural networks, such as Resnet50, MobilenetV2, Xception, and ShufflenetV2, our model and method require fewer parameters and achieve higher accuracy.
In view of the sudden grid voltage distortions, such as voltage sags and unbalances, that may occur in photovoltaic (PV) grid-connected systems under local shading conditions, this paper proposes a control strategy integrating a linear active disturbance rejection controller (LADRC)-based virtual synchronous generator (VSG) and an active disturbance rejection controller (ADRC)-based dynamic voltage restorer (DVR). To enhance the stability and response speed of the PV inverter system, a novel LADRC-based voltage–current dual closed-loop control strategy with pre-synchronization is designed, ensuring stable operation of the inverter and load. To address the overshooting issues found in traditional PI control under local shading, the ADRC-based DVR compensates for PV system voltage fluctuations, achieving rapid voltage distortion compensation and ensuring grid-connected system safety. Simulink experiments verify the feasibility and effectiveness of the proposed control strategy in improving transient voltage quality in PV systems affected by local shading. The total harmonic distortion rates of voltage and current are both less than 0.5%, which significantly improves the performance compared to existing research.
At present, the spring assembly defect detection of automobile airbags mainly adopts the manual detection method, which has problems such as low detection efficiency and low accuracy. This paper proposes an improved algorithm based on HOG-SVM. Firstly, the depth image of the automobile airbag parts is acquired. Secondly, the differential evolution algorithm is introduced into the HOG algorithm for optimization to extract the gradient histogram features in the depth image. Finally, the SVM algorithm is utilized for defect detection and identification of four spring assembly defects. Through comparison experiments with popular defect detection algorithms, the method proposed in this paper has higher detection accuracy and recognition accuracy than popular defect detection algorithms, with a detection accuracy of 99.115% and a recognition efficiency of 86.7257%, and is verified by using real sample data, with a detection accuracy of 92% and a recognition accuracy of 80%, respectively.
13 November 2025 in IEEE Transactions on Instrumentation and Measurement
With the widespread application of Ultra-High Voltage (UHV) cables in urban power transmission, ensuring quality control and safety during underground installation presents significant challenges. To address potential hazards such as excessive bending radius, local overpressure, and speed fluctuations, this paper proposes a real-time monitoring method for underground UHV cable laying. The method integrates a distributed measurement network (including vertical side pressure sensors, multi-dimensional side pressure sensors, and speed and meter sensors) with digital twins to enable comprehensive state monitoring and dynamic optimization of the cable-laying process. By employing a Unity3D–COMSOL coupled simulation engine, the approach establishes a risk prediction mechanism driven by the curvature–load ratio and velocity–pressure coupling factor, enabling early diagnosis of bending deformation and dynamic load impacts. Experimental results show that the method achieves millisecond-level data synchronization through a Modbus RTU/TCP hybrid protocol. Furthermore, by combining tri-state hierarchical warnings with multi-physical field verification, it effectively identifies risks of mechanical overload and hidden electromagnetic losses. Overall, the research provides intelligent technical support for quality control in complex cable-laying environments and demonstrates strong practical application value.