Mohamed Nour

Dr. Mohamed Nour

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
BABenhamou Aissa
Benhamou Aissa
THTedjini Hamza
Tedjini Hamza
GYGuettaf Yacine
Guettaf Yacine
MNMohamed Nour
Mohamed Nour
Due to the reliability and relatively low cost and modest maintenance requirement of the induction machine make it one of the most widely used machines in industrial applications. The speed control is one of many problems in the traction system, researchers went to new paths instead the classical controllers as PI controller, they integrated the artificial intelligent for its yield. The classical DTC is a method of speed control by using speed sensor and PI controller, it achieves a decoupled control of the electromagnetic torque and the stator flux in the stationary frame, besides, the use of speed sensors has several drawbacks such as the fragility and the high cost, for this reason, the specialists went to propose an estimators as Kalman filter. The fuel cell is a new renewable energy, it has many applications in the traction systems as train, bus. This paper presents an improved control using DTC by integrate the neural network strategy without use speed sensor (sensorless control) to reduce overtaking and current ripple and static error in the system because the PI controller has some problems like this; and reduce the cost with use a renewable energy as fuel cell.

1 September 2019 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
MNMohamed Nour
Mohamed Nour
THTedjini Hamza
Tedjini Hamza
GBGasbaoui Brahim
Gasbaoui Brahim
The application of the direct torque control strategy for induction machine drives is mainly characterized by torque and flux distortions caused by voltage vector limitation. The goal of this paper is to perform the conventional DTC induction machine drives and reduce ripples of both flux and torque response. The proposed contribution is based on the control of the DC output side of the rectifier feeding the voltage source inverter by means of PI controller in order to adapt the voltage vector used in typical DTC switching table. Mathematic models are built using MATLAB Simulink and programming environment; the simulation results show the difference between the proposed method and classical DTC.

1 April 2024 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
ATAli Abderrazak Tadjeddine
Ali Abderrazak Tadjeddine
IAIliace Arbaoui
Iliace Arbaoui
HHHamiani Hichem
Hamiani Hichem
MNMohamed Nour
Mohamed Nour
MAMohamed Alami
Mohamed Alami
Voltage control strategies (VCS) and frequency stability analysis (FSA) are essential for power system reliability, particularly during high-load periods. Stable voltage and frequency levels prevent malfunction, power quality deterioration, and supply interruptions. Grid operators must skillfully manage VCS and FSA control to ensure system stability. Nonlinear loads, especially under transient conditions, significantly affect voltage stability (VS), introducing harmonics, waveform distortion, and stability complexities. Accurate modeling of these nonlinear loads is vital when traditional static load models fall short. Frequency fluctuations from power generation-demand imbalances require vigilant monitoring and regulation. Effective frequency control mechanisms are indispensable for preserving desired frequencies. Using a Western Algeria case study, this paper underscores FSA's significance in integrating photovoltaic (PV) systems into power grids. It addresses challenges from frequency fluctuations due to dynamic ZIP load profiles, emphasizing the importance of FSA for reliable grid operation. The study offers insights and practical approaches to enhance VS, FSA control, and energy management (EM), improving grid reliability and ensuring uninterrupted power supply. We must look into FSA's benefits in integrating PV systems to improve performance and lower grid interruptions. This includes looking into its control mechanisms and feedback systems.

8 November 2026 in Journal of Optics
Verified
Journal Article
Closed access
PDF file
MNMohamed Nour
Mohamed Nour
ABAbdelkrim Benali
Abdelkrim Benali
SRSalima Khaoula Reguieg
Salima Khaoula Reguieg
HGHocine Guentri
Hocine Guentri
BSBoumediene Saied
Boumediene Saied
ANAbdelfatah Nasri
Abdelfatah Nasri

16 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
MNMohamed Nour
Mohamed Nour
Abdelkrim BENALIAbdelkrim BENALI
Abdelkrim BENALI
HGHocine Guentri
Hocine Guentri
BSBoumediene Saied
Boumediene Saied
NANasri Abdelfatah
Nasri Abdelfatah
Field-oriented control and direct torque control of induction-motor (IM) drives, and conventional finite-control-set model predictive control (FCS-MPC), all depend explicitly on machine parameters that drift with temperature and saturation, degrading current quality and, for the predictive case, even threatening closed-loop stability. This paper develops a parameter-robust, weighting-factor-less model-free predictive current control (MFPCC) for IM drives, in which the lumped disturbance of an ultra-local model is reconstructed online by a linear extended-state observer (ESO) and the inverter state is chosen by a current-only cost function. A two-step (k+2) prediction horizon is utilized to explicitly compensate for the one-sample microprocessor computation-and-actuation delay inherent to digital predictive control. The speed loop is governed by a model-free intelligent-proportional controller; thus, no proportional-integral current regulator and no machine parameter appear in the control path, with the single exception of the ultra-local model design gain α, which is fixed at the nominal input gain 1/σ Ls to establish parameter robustness. A comparative disturbance-observer study shows that the finite-difference estimator amplifies measurement noise and that an adaptive super-twisting observer cannot track the fast back electromotive force (back-EMF)-dominated lumped term of the IM at practical sampling rates, whereas the ESO tracks it faithfully (correlation 0.98). Under full inverter non-idealities (3 µs dead-time, 12-bit quantization, 50 mA offset, and 3% DC-link ripple), the proposed scheme attains 3.2% stator-current THD, matching an accurately tuned model-based FCS-MPC (3.9%) and significantly outperforming the finite-difference baseline (11.3%) while using none of the five machine parameters. Closed-loop stability and robust tracking are confirmed via a 50-run Monte-Carlo study, while a DSP timing estimate confirms real-time feasibility.

1 August 2026 in Solar Energy and Sustainable Development journal
Verified
Journal Article
Open access
PDF file
NCNourelHouda Cheggoufi
NourelHouda Cheggoufi
MNMohamed Nour
Mohamed Nour
BSBoumediene Saied
Boumediene Saied
NANasri Abdelfatah
Nasri Abdelfatah
ABAbdelkrim Benali
Abdelkrim Benali
Effective energy management is necessary for reliable power distribution and the best use of resources in DC microgrid hybrid energy systems. This study outlines an energy management method for an autonomous DC microgrid that incorporates a photovoltaic (PV) generator and a battery li-ion coupled to a DC-linkby converters DC/DC, accommodating both DC and AC loads. The photovoltaic generator is linked to a boost converter. This converter is controlled via a MPPT algorithm that uses perturbation and observation (P&O) to find the best way to get solar power when the amount of sunlight changes. The battery is connected to a buck-boost bidirectional converter at the same time, and a fuzzy logic-based energy management system (EMS) controls how it works.This controller regulates the selection of the battery operating mode (charge/discharge) based on load demand and the state of charge (SOC) of the battery, there by maintaining the stability of the DC-link voltage. The incorporation of MPPT with EMS facilitates efficient load distribution and energy equilibrium, consequently enhancing system performance and reliability.