Gungyu Kim

Mr. Gungyu Kim

Department of Convergence and Fusion System Engineering, Kyungpook National University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2024 in Reliability Engineering & System Safety
Verified
Journal Article
Closed access
Gungyu KimGungyu Kim
Gungyu Kim
SKShinyoung Kwag
Shinyoung Kwag
SESeunghyun Eem
Seunghyun Eem
DHDae-Gi Hahm
Dae-Gi Hahm
JPJin Hee Park
Jin Hee Park

19 November 2024 in Geomatics, Natural Hazards and Risk
Verified
Journal Article
Open access
SJSeung-Seop Jin
Seung-Seop Jin
Gungyu KimGungyu Kim
Gungyu Kim
SKShinyoung Kwag
Shinyoung Kwag
SESeunghyun Eem
Seunghyun Eem

1 January 2026 in International Journal of Energy Research
Verified
Journal Article
Open access
Gungyu KimGungyu Kim
Gungyu Kim
SKShinyoung Kwag
Shinyoung Kwag
SESeunghyun Eem
Seunghyun Eem
JPJinhee Park
Jinhee Park
JHJEONGGON HA
JEONGGON HA
Earthquakes affect not only nuclear power plants (NPPs) but also the surrounding infrastructure and essential response agencies. According to the emergency‐response procedures stipulated by the Nuclear Safety and Security Commission, organizations such as fire departments, police stations, local governments, and Korea Hydro and Nuclear Power (KHNP) support personnel are required to implement resident protection measures and facilitate nuclear‐accident recovery. This study derived quantitative indicators of earthquake‐induced damage conditions in the vicinity of NPPs. Focusing on the Hanul NPP site, scenarios were applied assuming safe shutdown earthquake levels of 0.2 g and 0.3 g, as well as the maximum possible earthquake magnitude in the Korean Peninsula (Mw 7.0). Using domestic attenuation relationships and building fragility curves based on spectral acceleration, the probabilities of building‐level damage and time‐dependent human casualties were estimated. The analysis indicated that as earthquake magnitude increases, damage to major public facilities—such as local government offices, fire stations, health centers, and hospitals—increases rapidly, reaching levels close to Extensive–Complete under the Mw 7.0 scenario. Widespread damage is also expected in KHNP residential complexes that accommodate nuclear plant personnel. Time‐of‐day analysis confirmed that residential facilities experience concentrated casualties at night (22:00–06:00), whereas office facilities show casualty concentration during daytime working hours. Building‐level assessments were performed to reflect Korea’s seismic characteristics and building fragility. Time‐dependent casualties and peak casualty occurrence periods were identified, and the vulnerability of support facilities directly involved in nuclear‐accident response was quantified. These results provide quantitative evidence to inform accident‐management and emergency‐response planning, serving as baseline data for enhancing the safety of communities surrounding NPPs.

25 June 2026 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
Gungyu KimGungyu Kim
Gungyu Kim
SKShinyoung Kwag
Shinyoung Kwag
JHJEONGGON HA
JEONGGON HA
JPJinhee Park
Jinhee Park
SESeunghyun Eem
Seunghyun Eem

18 September 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
Gungyu KimGungyu Kim
Gungyu Kim
SESeunghyun Eem
Seunghyun Eem
SKShinyoung Kwag
Shinyoung Kwag
JJJae-Wook Jung
Jae-Wook Jung
BJBub-Gyu Jeon
Bub-Gyu Jeon
As climate change increases typhoon intensity and frequency, typhoon-induced high winds increasingly threaten nuclear power plant (NPP) safety by disrupting off-site power systems. Previous probabilistic safety assessments (PSAs) evaluated this risk using transmission tower fragility models derived from high-wind fragility equations developed for NPP structures, systems, and components. However, these models do not adequately reflect the structural characteristics of Korean transmission towers. In this study, a PSA of the off-site power system at the Kori NPP site under typhoon-induced high winds was performed using a universal voltage-class-based fragility model developed for Korean transmission towers. To isolate the effect of the fragility model on risk estimates, the typhoon hazard, network, and damage correlation conditions were set identically to those adopted in previous research. The Korean universal fragility model produced a higher median wind speed but a lower high-confidence-of-low-probability-of-failure capacity, resulting in an increase in the estimated annual risk. Because the lower HCLPF extends the probability of damage to lower wind speeds, which occur more frequently, the annual risk increases despite the greater median capacity. The risk-contribution analysis showed that the overall risk was governed by the overlap between the 0–50% range of the fragility curve and the hazard below its 100-year return period, rather than by the median failure wind speed. The analysis further demonstrated that the choice of logarithmic standard deviation shifts the governing wind-speed range. Therefore, realistic assessments require fragility models developed specifically for Korean transmission towers. These findings provide a quantitative basis for estimating the frequency of loss of off-site power events at NPPs, thereby contributing to resilient and sustainable infrastructure management.

20 October 2026 in Structure and Infrastructure Engineering
Verified
Journal Article
Closed access
Gungyu KimGungyu Kim
Gungyu Kim
SESeunghyun Eem
Seunghyun Eem
SKShinyoung Kwag
Shinyoung Kwag
JHJEONGGON HA
JEONGGON HA
BJBub-Gyu Jeon
Bub-Gyu Jeon
1. The power system constitutes a fundamental component of modern infrastructure (Liu et al., 2025). Disruptions within power networks extend beyond temporary interruptions in electricity supply an...